Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

LeMaitre Vascular, Inc.

United States·US-MF-000016778

Last updated September 17, 2026

About

At LeMaitre, we've dedicated our lives to innovation and research to create tools for the vascular surgeon of today and tomorrow.

From the manufacturer's own website. Source

Information

Country
United States
Address
63, Second Avenue, Burlington, Massachusetts, United States
Facebook
—
Phone
+1 781-425-1735
PRRC Contact
Andrew Hodgkinson
EUDAMED SRN
US-MF-000016778
FDA FEI Number
1220948
DUNS Number
—

Catalogue (569)

Page 10 of 12
DeviceModel / ReferenceRegistriesClassStatus
LeMaitre Embolectomy Catheter 1801-68
FDA UDI
Class IIActive
LeMaitre Embolectomy Catheter e1801-34
FDA UDI
Class IIActive
AnastoClip GC 8cm (Large) 4008-07
FDA UDI
Class IIActive
LifeSpan ePTFE Vascular Graft R06040CS
FDA UDI
Class IIUnknown
Trivex System 7205683
FDA UDI
Class IIActive
Flexcel Carotid Shunt 2020-45
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft ATC2010
FDA UDI
Class IIUnknown
Martin Dissector 4200-10
FDA UDI
Class IIActive
Pruitt Aortic Occlusion Catheter e2100-12
FDA UDI
Class IIActive
Pruitt F3 Carotid Shunt 2013-10
FDA UDI
Class IIActive
HYDRO LeMaitre Valvulotome 1010-00
FDA UDI
Class IIActive
XenoSure Biologic Patch e4P6
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft AMC1408
FDA UDI
Class IIUnknown
LifeSpan ePTFE Vascular Graft GT74070
FDA UDI
Class IIUnknown
Syntel Silicone Thrombectomy Catheter A4538
FDA UDI
Class IIActive
LifeSpan ePTFE Vascular Graft R06050
FDA UDI
Class IIUnknown
LeMaitre Embolectomy Catheter e1651-48
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft AMC1608
FDA UDI
Class IIUnknown
LifeSpan ePTFE Vascular Graft R07010
FDA UDI
Class IIUnknown
CardioCel Neo Bioscaffold Patch 5 cm X 8 cm UC0508N
FDA UDI
Class IIActive
LifeSpan ePTFE Vascular Graft R08080
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft ATC1538
FDA UDI
Class IIUnknown
Anastoclip AC Closure System 4000-06
FDA UDI
Class IIActive
LeMaitre Embolectomy Catheter 1651-88
FDA UDI
Class IIActive
LeMaitre Aortic Occlusion Catheter 2107-80
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft ATC6014
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft AMC1524
FDA UDI
Class IIUnknown
Syntel Silicone OTW Embolectomy Catheter A4E04
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft AMC3022
FDA UDI
Class IIUnknown
Trivex System 7209515
FDA UDI
Class IIActive
InvisiGrip Vein Stripper 1500-01
FDA UDI
Class IUnknown
AlboGraft Polyester Vascular Graft ATC3006
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft AMC6006
FDA UDI
Class IIUnknown
Anastoclip AC Closure System 4000-08
FDA UDI
Class IIActive
CardioCel Bioscaffold Patch 6 cm X 14 cm UC0614C
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft ATC9030
FDA UDI
Class IIUnknown
Reddick Scoop Tip Cholangiogram Catheter e2401-53
FDA UDI
Class IActive
LeMaitre Aortic Occlusion Catheter 2107-81
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft AMC8008
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft AMC3008
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft ATC6038
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft ATC1534
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft AMC6022
FDA UDI
Class IIUnknown
AlboGraft Polyester Vascular Graft ATC9032
FDA UDI
Class IIUnknown
ProCol Biologic Vascular Graft HJL016-10-N
FDA UDI
Class IIIActive
AlboGraft Polyester Vascular Graft AMC4020
FDA UDI
Class IIUnknown
Pruitt Aortic Occlusion Catheter 2100-12
FDA UDI
Class IIActive
AnastoClip GC 8cm (XLarge) 4008-08
FDA UDI
Class IIActive
AlboGraft Polyester Vascular Graft AMC4006
FDA UDI
Class IIUnknown
Polyurethane Dual Lumen Occlusion Catheter 4F-2L-40
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (84)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Feb 10, 2026Z-1574-2026—open, classified

Labeling mix-up resulting in the incorrect lot outer packaging of product.

Sep 25, 2025Z-0289-2026—open, classified

The device was incorrectly packed in the wrong size labeled outer packaging.

Sep 2, 2025Z-0034-2026—open, classified

The bovine carotid arteries used to produce the impacted grafts from affected lots were sourced using raw material from a supplier that had not been reviewed and approved by the appropriate regulatory authority.

Aug 25, 2025Z-0072-2026—open, classified

Devices were distributed with incorrect label without CE and UKCA mark, missing patient leaflet and patient implant card.

Apr 11, 2025Z-1750-2025—open, classified

During internal product testing, it was observed that some packages to have incomplete seals (sterile barrier).

Apr 11, 2025Z-1752-2025—open, classified

During internal product testing, it was observed that some packages to have incomplete seals (sterile barrier).

Apr 11, 2025Z-1751-2025—open, classified

During internal product testing, it was observed that some packages to have incomplete seals (sterile barrier).

Apr 17, 2024Z-1824-2024—open, classified

The guide tip can become damaged and result in the tip detaching.

Jul 13, 2023Z-2468-2023—open, classified

Burrs (molding flash) on the cutter may tear the harvested vien

Sep 30, 2022Z-0228-2023—open, classified

Three lots tied by two trainees were released without performing the required pull test. If tied with inadequate strength, the proximal ligature could slip toward the tip of the catheter and block the inflation hole, leading to the risk of the tip breaking off, and potentially becoming lost in the blood vessel.

Apr 6, 2021Z-1529-2021—terminated

The firm received a complaint regarding particulate found in the packaging foam that could contaminate the sterile field.

Mar 23, 2020Z-1567-2020—open, classified

There has been an increased trend in reports of catheters failing to deflate during use, which may ultimately lead to tip separation.

Jul 24, 2019Z-2448-2019—terminated

incorrect device size being listed on the impacted device packaging

Oct 1, 2018Z-0473-2019—terminated

Pouches from this lot are not sealed compromising the sterility

Jun 19, 2018Z-3042-2018—terminated

The wrong instructions for use (IFU) were supplied with the AnastoClip GC closure system. The IFU provided lists some indications which are not cleared by the FDA for devices distributed in the United States: 1) closure of arteriotomies and veinotomies, 2) attachment of synthetic vascular prostheses, and 3) approximation of dural tissue.

Feb 7, 2017Z-1450-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1442-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1447-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1449-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1446-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1444-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1445-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1448-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1453-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1443-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1451-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Feb 7, 2017Z-1452-2017—terminated

The Contains Latex symbol was not printed onto the box label or the sterile (inner) product pouch

Aug 3, 2016Z-2545-2016—terminated

Wire which deploys the loop may be come detached at the handle causing the device to be inoperable

Aug 3, 2016Z-2543-2016—terminated

Wire which deploys the loop may be come detached at the handle causing the device to be inoperable

Aug 3, 2016Z-2544-2016—terminated

Wire which deploys the loop may be come detached at the handle causing the device to be inoperable

Jun 22, 2016Z-2283-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use

Jun 22, 2016Z-2284-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Jun 22, 2016Z-2288-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Jun 22, 2016Z-2285-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Jun 22, 2016Z-2286-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Jun 22, 2016Z-2289-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Jun 22, 2016Z-2287-2016—terminated

US marketing brochure for the AnastoClip AC Closure System states that the Anastoclip catalog numbers can be used for dura closure, but the catalog numbers are only intended for cardiovascular use.

Oct 21, 2015Z-0383-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0388-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0390-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0378-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0386-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0385-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0384-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0381-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0379-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0380-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0389-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0387-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Oct 21, 2015Z-0382-2016—terminated

Manufacturing issue that could cause a pinhole in the formed end of the packaging, which may lead to compromised sterility.

Feb 24, 2015Z-1294-2015—terminated

Mislabeled with an incorrect expiration date

Jun 17, 2013Z-1758-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1760-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1756-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1755-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1762-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1769-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1770-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1757-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1759-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1764-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1761-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1768-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1754-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1766-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1763-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1767-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Jun 17, 2013Z-1765-2013—terminated

Blood blushing/leaking from the surface of the graft after implantation

Mar 18, 2013Z-1054-2013—terminated

Devices were not sealed correctly during the manufacturing process, and the sterility of these products have been compromised.

Mar 18, 2013Z-1055-2013—terminated

Devices were not sealed correctly during the manufacturing process, and the sterility of these products have been compromised.

Oct 4, 2011Z-0070-2012—terminated

Extended Expiration on the outer box label 2016-05, the correct expiration date is on the tray label: 2014-05

Oct 22, 2010Z-0436-2011—terminated

Box label (Top Part). Lot and Expiration Date information were switched.

Oct 22, 2010Z-0434-2011—terminated

Box label (Top Part). Lot and Expiration Date information were switched.

Oct 22, 2010Z-0433-2011—terminated

Box label (Top Part). Lot and Expiration Date information were switched.

Oct 22, 2010Z-0435-2011—terminated

Box label (Top Part). Lot and Expiration Date information were switched.

Sep 22, 2010Z-0165-2011—terminated

Mislabeled size on external packaging: The contents section listed on the Tyvek lid labels of the Medium and Large sizes incorrectly identified the size of the clip as XL, while the device inside was either a Medium or Large size.

Sep 22, 2010Z-0164-2011—terminated

Mislabeled size on external packaging: The contents section listed on the Tyvek lid labels of the Medium and Large sizes incorrectly identified the size of the clip as XL, while the device inside was either a Medium or Large size.

Jul 18, 2007Z-0008-2008—terminated

Sterility of device may be compromised due to breach in sterile barrier.

May 17, 2005Z-0219-06—terminated

LeMaitre Vascular is recalling certain lots of its Pruitt Aortic Occlusion Catheters due to a packaging defect which could compromise product sterility.

Feb 7, 2005Z-0557-05—terminated

Product sterility maybe compromised due to defective packaging

Feb 7, 2005Z-0561-05—terminated

Product sterility maybe compromised due to defective packaging

Feb 7, 2005Z-0559-05—terminated

Product sterility maybe compromised due to defective packaging

Feb 7, 2005Z-0558-05—terminated

Product sterility maybe compromised due to defective packaging

Feb 7, 2005Z-0560-05—terminated

Product sterility maybe compromised due to defective packaging