Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

Medtec LLC

United States·US-MF-000002608

Last updated September 17, 2026

Information

Country
United States
Address
1401, 8th Street SE, Orange City, United States
Website
cqmedical.com
LinkedIn
—
Facebook
—
Phone
+17127378688
PRRC Contact
Alena Newgren
EUDAMED SRN
US-MF-000002608
FDA FEI Number
1000143606
DUNS Number
—

Catalogue (1098)

Page 10 of 22
DeviceModel / ReferenceRegistriesClassStatus
IPPS Overlay 20IL430135
FDA UDI
Class IIUnknown
Body Pro-Lok ONE™ System BPL110
FDA UDI
Class IIUnknown
AccuForm™ Cushion MTACL2035HF
FDA UDI
Class IIActive
Vac-Lok™ Cushion VLWGB05C
EUDAMEDFDA UDI
Class IIActive
Prodigy™ Lok-Bar™ MTIL3653
FDA UDI
Class IIActive
Universal Couchtop MTIL6064
FDA UDI
Class IIUnknown
IPPS™ Overlay MTM3405
FDA UDI
Class IIActive
Fiducial Marker Kit MTNW887871
EUDAMEDFDA UDI
Class IIActive
IPPS™ Overlay MTM3301
FDA UDI
Class IIUnknown
Prodigy™ 2 Lok-Bar™ MTIL6051
FDA UDI
Class IIActive
Docking Station MTIL301310
FDA UDI
Class IIUnknown
Clamp MTSBRT256
EUDAMEDFDA UDI
Class IIActive
IPPS™ Overlay MTM330110
FDA UDI
Class IIUnknown
Vac-Lok™ Cushion VLPLV10FC
EUDAMEDFDA UDI
Class IIActive
Posicast® Thermoplastic 976150
FDA UDI
Class IIUnknown
Headrest - TIMO Size A, B, C, D, E, F MTTIMO2
EUDAMEDFDA UDI
Class IIActive
Uni-frame® Thermoplastic MTAPU12
EUDAMEDFDA UDI
Class IIActive
Lok-Bar™ MTSBRT055
FDA UDI
Class IIActive
Posicast® Thermoplastic 930033
EUDAMEDFDA UDI
Class IIActive
Fiducial Markers MTNW887809
FDA UDI
Class IIActive
Protura 206X140
FDA UDI
Class IIUnknown
trUpoint ARCH Replacement Kit MTHF175
FDA UDI
Class IIUnknown
Body Pro-Lok™ Platform MTSBRT002
EUDAMEDFDA UDI
Class IIActive
Prodigy™ 2 Lok-Bar™ MTIL6056
FDA UDI
Class IIActive
Respiratory Plate BPL008
EUDAMEDFDA UDI
Class IIActive
Positioning Cushion 301076
FDA UDI
Class IIActive
Spacer 107104MR
EUDAMEDFDA UDI
Class IIActive
Body Pro-Lok™ Bridge MTSBRT031
FDA UDI
Class IIActive
Type-S™ Thermoplastic MTAPSP2.4
EUDAMEDFDA UDI
Class IIActive
Posiboard™ 109030
FDA UDI
Class IIUnknown
Couchtop Panel MTIL3103
FDA UDI
Class IIUnknown
Headrest - Timo size B MTTIMO2B
EUDAMEDFDA UDI
Class IIActive
ProForm™ CT Overlay PRO310
FDA UDI
Class IIUnknown
IPPS Overlay MTIL6363
FDA UDI
Class IIUnknown
Docking Station MTIL630110
FDA UDI
Class IIUnknown
IPPS™ Overlay MTM3400
FDA UDI
Class IIUnknown
Uni-frame® Baseplate MT20100CF
EUDAMEDFDA UDI
Class IIActive
Uni-frame® Thermoplastic MTAPUIW1832VT
EUDAMEDFDA UDI
Class IIActive
Vac-Lok™ Cushion VLARM02
FDA UDI
Class IIUnknown
Vac-Lok Cushion MTVLWGB03C
FDA UDI
Class IIUnknown
Butt Stop Bar Replacement Set MT350N027
FDA UDI
Class IIUnknown
TotalRT All In One Platform TRT100
FDA UDI
Class IIActive
Fiducial Marker Kit MTNW887866
FDA UDI
Class IIActive
Vac-Lok™ Cushion MTVLPLV01
FDA UDI
Class IIUnknown
Posicast® Thermoplastic 930044
EUDAMEDFDA UDI
Class IIActive
Immobilizer MTDLIZ
FDA UDI
Class IIUnknown
Positioning Cushion 301081
EUDAMEDFDA UDI
Class IIActive
IPPS Overlay MTIL4300
FDA UDI
Class IIUnknown
Couchtop Panel MTIL301001
FDA UDI
Class IIUnknown
McLaurin Arch MTPT1002
FDA UDI
Class IIUnknown

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (14)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
May 12, 2020Z-2243-2020—terminated

Potential for disengagement of the Varian Style Type-S Extension during patient repositioning. The risk associated with the disengagement of the extension could be a patient fall if the patient is not supported by clinical staff.

Apr 15, 2019Z-1837-2019—terminated

There is a potential for movement of the Solstice Tilting Head Fixation System during patient setup and/or treatment.

Nov 8, 2017Z-0671-2018—terminated

When an error message remains displayed and is not cleared in the Protura software with the Elekta pedestal coordinates, moving the pedestal could cause the Protura software to not update with the pedestal location and buffers the pedestal movement history.

Aug 10, 2017Z-3082-2017—terminated

Rigid Arm Supports (PN: 106015 and 106047), which were used as part of the Posiboard-2 and Posirest, and were distributed as PN: 106015, 106047, 106521, 106522, 109030, and 109040 between Ocotober 2009 and July 2012 may have a height difference of approximately 17mm.

Aug 10, 2017Z-3083-2017—terminated

Rigid Arm Supports (PN: 106015 and 106047), which were used as part of the Posiboard-2 and Posirest, and were distributed as PN: 106015, 106047, 106521, 106522, 109030, and 109040 between Ocotober 2009 and July 2012 may have a height difference of approximately 17mm.

Mar 31, 2016Z-1992-2016—terminated

When using the recalled product in split shift mode, the non-sub-millimeter positioning has been found to be inconsistent with the setting parameters.

Aug 19, 2015Z-2763-2015—terminated

The wrist straps used for positioning the patient are too long

Dec 11, 2014Z-0989-2015—terminated

The product (wool wrist loop) was manufactured 7cm shorter than product specifications.

Dec 11, 2014Z-0990-2015—terminated

The product (wool wrist loop) was manufactured 7cm shorter than product specifications.

Jun 21, 2010Z-0394-2011—terminated

Under certain conditions, the extensions can become detached from the main body of the couch.

Jun 21, 2010Z-0395-2011—terminated

Under certain conditions, the extensions can become detached from the main body of the couch.

Jun 21, 2010Z-0396-2011—terminated

Under certain conditions, the extensions can become detached from the main body of the couch.

Aug 31, 2009Z-0124-2010—terminated

Some of the packages contain the incorrect mask style.

Mar 6, 2009Z-1721-2009—terminated

The silkscreened indexing scale was reversed.