MICROBIOLOGICS, INC.

United States·US-MF-000000466

Last updated September 17, 2026

Information

Country
United States
Address
200, Cooper Avenue North, Saint Cloud, United States
LinkedIn
—
Facebook
—
Phone
+1 320 253 7400
PRRC Contact
Tina Sobania
EUDAMED SRN
US-MF-000000466
FDA FEI Number
2150138
DUNS Number
—

Catalogue (2120)

Page 1 of 43
DeviceModel / ReferenceRegistriesClassStatus
KWIK-STIK™ and LYFO DISK™ [0755K] KWIK-STIK™ E. hormaechei ATCC 700323™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0885K] KWIK-STIK™ L. acidophilus ATCC 314™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0684P] KWIK-STIK™ K. pneumoniae ATCC 10031™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0633K] KWIK-STIK™ S. pneumoniae ATCC 49150™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0890P] KWIK-STIK™ S. Abony NCTC 6017
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0661P] KWIK-STIK™ E. rhusiopathiae ATCC 19414™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0937K] KWIK-STIK™ S. aureus ATCC 49476™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0841K] KWIK-STIK™ P. vulgaris ATCC 6896™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0896K] KWIK-STIK™ C. albicans ATCC 2091™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0813K] KWIK-STIK™ L. fermentum ATCC 9338™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0648K] KWIK-STIK™ N. gonorrhoeae ATCC 49226™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0794K] KWIK-STIK™ P. venetum ATCC 16025™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0680P] KWIK-STIK™ E. coli ATCC 10536™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0981K] KWIK-STIK™ C. albicans ATCC 66027™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0774K] KWIK-STIK™ C. lusitaniae ATCC 34449™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0852P] KWIK-STIK™ S. aureus ATCC 43300™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0697K] KWIK-STIK™ R. equi ATCC 6939™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0978K] KWIK-STIK™ S. species (F 2) ATCC 12392™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0409P] KWIK-STIK™ F. magna ATCC 29328™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0842K] KWIK-STIK™ B. parapertussis ATCC 15311™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0780P] KWIK-STIK™ P. wickerhamii ATCC 16529™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0872P] KWIK-STIK™ G. stearothermophilus ATCC 12980™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0781K] KWIK-STIK™ C. neoformans ATCC 204092™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0726P] KWIK-STIK™ C. parapsilosis ATCC 22019™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0947K] KWIK-STIK™ S. pneumoniae ATCC 49619™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0619P] KWIK-STIK™ B. uniformis ATCC 8492™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0377K] KWIK-STIK™ H. parahaemolyticus ATCC 10014™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0868K] KWIK-STIK™ O. ureolytica ATCC 43534™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0750K] KWIK-STIK™ A. viscosus ATCC 15987™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0983P] KWIK-STIK™ C. tropicalis ATCC 66029™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0631P] KWIK-STIK™ S. gallolyticus ATCC 49147™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0712K] KWIK-STIK™ C. jejuni NCTC 13367
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0795K] KWIK-STIK™ E. coli (O157:H7) ATCC 43888™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0895K] KWIK-STIK™ E. gallinarum ATCC 49573™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0699K] KWIK-STIK™ S. cerevisiae ATCC 9763™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0640P] KWIK-STIK™ P. vulgaris ATCC 49132™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0969P] KWIK-STIK™ S. mutans ATCC 35668™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0869P] KWIK-STIK™ E. coli ATCC 51446™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0986K] KWIK-STIK™ C. glabrata ATCC 66032™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0945K] KWIK-STIK™ S. saprophyticus ATCC 49453™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0847P] KWIK-STIK™ C. tropicalis ATCC 750™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0728K] KWIK-STIK™ T. thermosaccharolyticum ATCC 7956™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0948P] KWIK-STIK™ S. multivorum ATCC 35656™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0660P] KWIK-STIK™ T. pyogenes ATCC 19411™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0993K] KWIK-STIK™ H. influenzae ATCC 35056™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0990P] KWIK-STIK™ C. kefyr ATCC 2512™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0999P] KWIK-STIK™ B. paranthracis ATCC 13061™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0689K] KWIK-STIK™ M. luteus ATCC 10240™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0838K] KWIK-STIK™ S. liquefaciens ATCC 27592™
EUDAMED
Class BActive
KWIK-STIK™ and LYFO DISK™ [0743P] KWIK-STIK™ S. zooepidemicus ATCC 700400™
EUDAMED
Class BActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (67)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Dec 2, 2025Z-0986-2026—open, classified

Affected units may fail to recover the target microorganism Campylobacter jejuni subsp. jejuni derived from ATCC 29428.

Dec 2, 2025Z-0985-2026—open, classified

Affected units may fail to recover the target microorganism Campylobacter jejuni subsp. jejuni derived from ATCC 29428.

Dec 2, 2025Z-0984-2026—open, classified

Affected units may fail to recover the target microorganism Campylobacter jejuni subsp. jejuni derived from ATCC 29428.

Nov 13, 2025Z-0876-2026—open, classified

Some products packaged for lot 818-111-7 may have been packaged in pouches labeled as lot 857-53-10.

Jun 27, 2025Z-2195-2025—open, classified

KWIK-STIK REF numbers: 0894P, 0894K and LYFO DISK" 0894L may result in failure to recover the target microorganism. All lots of REF 894-76 are impacted.

Jun 27, 2025Z-2194-2025—open, classified

KWIK-STIK REF numbers: 0894P, 0894K and LYFO DISK" 0894L may result in failure to recover the target microorganism. All lots of REF 894-76 are impacted.

Jun 17, 2025Z-2124-2025—open, classified

Affected products contain Staphylococcus epidermidis instead of the expected Brevundimonas diminuta. This may cause the user's quality control to fail and delayed diagnosis for the patient.

May 27, 2025Z-1957-2025—open, classified

Affected products were packaged with the incorrect KWIK STIK assembly resulting in the product containing the wrong microorganism. 0621K was packaged 01065K swabs; 01065K was packaged with 0621K swabs. This may lead to delayed diagnosis.

Feb 20, 2025Z-1454-2025—open, classified

The RSV target may give a late Ct value and could potentially not pass QC.

Feb 20, 2025Z-1371-2025—open, classified

The A549 human cell target (human cells for sample adequacy control) may give a late Ct value.

Jan 20, 2025Z-1164-2025—open, classified

Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 L1) was low enough to cause QC failures, no detection, or invalid results on some instruments and assays.

Jan 20, 2025Z-1163-2025—open, classified

Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 L1) was low enough to cause QC failures, no detection, or invalid results on some instruments and assays.

Mar 6, 2024Z-1483-2024—open, classified

The positive control material (Rhizopus stolonifer) within the KWIK-STIK assembly was contaminated with another fungal organism (Aspergillus brasiliensis). As a result, users may observe A. brasiliensis growth when using the control material.

Jan 8, 2024Z-1075-2024—open, classified

The negative control was contaminated with one of the positive control pathogens (Norovirus). This would result in users getting a positive call for Norovirus when running the negative control.

Oct 18, 2023Z-0307-2024—open, classified

A complaint investigation showed that the bulk pellets (lot 794-142) were contaminated with Aspergillus flavus.

Oct 18, 2023Z-0308-2024—open, classified

A complaint investigation showed that the bulk pellets (lot 794-142) were contaminated with Aspergillus flavus.

Aug 14, 2023Z-2576-2023—open, classified

One lot of KWIK STIK ANA (3 strains) QC Set is missing one of the strains, 6018P Parabacteroides distasonis.

Jul 27, 2022Z-1740-2022—terminated

Product not registered for use in the UK

May 6, 2022Z-1125-2022—terminated

Labeling error.

Mar 24, 2022Z-0954-2022—terminated

QC process was not adequate for the specification range.

Mar 22, 2022Z-0955-2022—terminated

The QC process was not adequate for the specification range.

Mar 3, 2022Z-0844-2022—terminated

Shelf-life for the 8244 Pneumonia (33 Targets) Control Panel determined to be 6 months instead of 18 months.

Feb 25, 2022Z-0784-2022—terminated

Distributed product did not undergo proper release testing.

Aug 20, 2021Z-2486-2021—terminated

The SARS-CoV-2 Process Control (Pellet) contains RNA transcripts that include diagnostically relevant SARS-CoV-2 targets (CDC and WHO consensus sequences).

Aug 20, 2021Z-2487-2021—terminated

The product indicated is contaminated with a plasmid DNA that contains the target SARS-CoV-2 sequences.

Feb 24, 2021Z-0543-2022—terminated

Potential that products packaged for lot 726-57-10 were packaged in pouches labeled as 323-108-7.

Feb 24, 2021Z-0544-2022—terminated

Potential of products packaged for lot 323-108-7 were packaged in pouches labeled as 726-57-10.

Dec 16, 2020Z-0546-2022—terminated

The expiration date on the label of one component (negative control 0243U) in the set lot is incorrectly labeled. The KWIK-STIK negative control 0243U was labeled with an expiration date of 7/31/2020 when it should have been 7/31/2022.

Dec 16, 2020Z-0511-2022—terminated

Contamination with S. epidermidis

Oct 8, 2020Z-0303-2021—terminated

KWIK-STIK 6 Pack Klebsiella pneumoniae derived from NCTC 13443 (Catalog# 01145K) should contain the NDM-1 positive strain, but was confirmed to be NDM-1 negative.

Oct 8, 2020Z-0304-2021—terminated

QC Sets and Panels: KWIK-STIK 2 Pack (Catalog# 5226P) should contain the NDM-1 positive strain, but was confirmed to be NDM-1 negative.

Oct 8, 2020Z-0402-2021—terminated

Strain should be VIM-1 positive but is confirmed to be VIM-1 negative.

Oct 8, 2020Z-0581-2022—terminated

The incorrect lot number was printed on the foil pouch that the KWIK-STIK" is placed in. All foil pouches for lot 318-234-4 have the lot number misprinted as 218-234-4. The correct lot number was printed on the KWIK-STIK" canister label and KWIK-STIK" device label.

Oct 8, 2020Z-0302-2021—terminated

KWIK-STIK 2 Pack Klebsiella pneumoniae derived from NCTC 13443 (Catalog# 01145P) should contain the NDM-1 positive strain, but was confirmed to be NDM-1 negative.

Oct 1, 2020Z-0582-2022—terminated

Potential contamination with S. epidermidis E. coli and S. warneri.

Oct 1, 2020Z-0583-2022—terminated

Potential contamination with Escherichia coli, Staphylococcus epidermidis and S. warneri.

Oct 1, 2020Z-0584-2022—terminated

Potential contamination with Escherichia coli Staphylococcus epidermidis and S. warneri.

Feb 18, 2020Z-0587-2022—terminated

Tests returning incorrect susceptible results. High Level Gentamicin Synergy value was out of specification (sensitive) when analyzed on the Vitek 2 AST-GP67 card, and these lots failed the disk diffusion method used for product release.

Feb 18, 2020Z-0586-2022—terminated

Tests returning incorrect susceptible results. High Level Gentamicin Synergy value was out of specification (sensitive) when analyzed on the Vitek 2 AST-GP67 card, and these lots failed the disk diffusion method used for product release.

Feb 18, 2020Z-0589-2022—terminated

Tests returning incorrect susceptible results. High Level Gentamicin Synergy value was out of specification (sensitive) when analyzed on the Vitek 2 AST-GP67 card, and these lots failed the disk diffusion method used for product release.

Feb 18, 2020Z-0585-2022—terminated

Tests returning incorrect susceptible results. High Level Gentamicin Synergy value was out of specification (sensitive) when analyzed on the Vitek 2 AST-GP67 card, and these lots failed the disk diffusion method used for product release.

Feb 18, 2020Z-0588-2022—terminated

Tests returning incorrect susceptible results. High Level Gentamicin Synergy value was out of specification (sensitive) when analyzed on the Vitek 2 AST-GP67 card, and these lots failed the disk diffusion method used for product release.

Feb 12, 2020Z-1691-2020—terminated

KWIKSTIK 2 Pack (REF 0778P) and QC Set and Panels: KWIKSTIK YST Comprehensive QC Set (REF 5195P) contain product labeled as Trichosporon dermatis (T. dermatis) which may contain Candida Utilis instead of T. dermatis.

Feb 12, 2020Z-1690-2020—terminated

KWIKSTIK 2 Pack (REF 0778P) and QC Set and Panels: KWIKSTIK YST Comprehensive QC Set (REF 5195P) contain product labeled as Trichosporon dermatis (T. dermatis) which may contain Candida Utilis instead of T. dermatis.

Jan 3, 2020Z-1096-2020—terminated

Product 8208 Vaginal Verification Panel is a 6 pool kit and has contaminant Candida krusei in Pool 2 (subcomponent 6063). Candida krusei is an organism intended to be contained in Pool 6 of the kit. This should have no impact on patient test results as long as Gardnerella vaginalis was properly detected when using Pool 2 and/or users are strictly using this product for instrument verification/validation.

Dec 16, 2019Z-0812-2020—terminated

The recommended hydration fluid for the 8180 Gram-Positive Blood Culture Control Panel (Inactivated Pellet), has changed from sterile 0.85% saline or sterile blood culture media to sterile DI water or pH 7.2 phosphate buffer.

May 16, 2019Z-1838-2019—open, classified

Product is labeled with expiration date of 2021-10-31, should be 2021-03-31.

Apr 9, 2019Z-1731-2019—open, classified

Product with incorrect shelf life.

Apr 9, 2019Z-1730-2019—open, classified

Product with incorrect shelf life.

Jan 31, 2019Z-0982-2019—terminated

Cepheid Xpert Respiratory Control Panel (Catalog #8199) has an reduced expiration date from 24 months to 13 months.

Jun 6, 2017Z-0701-2022—terminated

Real-time shelf life testing failed at 24 months

Jun 6, 2017Z-0699-2022—terminated

Real-time shelf life testing failed at 24 months

Jun 6, 2017Z-0698-2022—terminated

Real-time shelf life testing failed at 24 months

Jun 6, 2017Z-0700-2022—terminated

Real-time shelf life testing failed at 24 months

Jun 6, 2017Z-0697-2022—terminated

Real-time shelf life testing failed at 24 months

Mar 2, 2017Z-0637-2022—terminated

Potential for product labeled as Actinomyces odontolyticus is actually Eggerthella lenta.

Mar 2, 2017Z-0636-2022—terminated

Potential for product labeled as Actinomyces odontolyticus is actually Eggerthella lenta.

Dec 1, 2015Z-0704-2022—terminated

The Lactobacillus acidophilus negative control (item 0243 single KWIK-STIK) contained in the 8164 Cepheid Xpert GBS QC Set and 8165 Cepheid Smart GBS QC Set was found to test positive for Group B Streptococcus (GBS) in some cases. This causes a failure when used as a quality control for the Cepheid Xpert GBS and Cepheid Smart GBS systems. The failure of the quality control test causes a disruption for the testing laboratory which may result in repeated testing or the need for alternative test methods. This recall is applicable to the 8164 and 8165 sets only.

Dec 1, 2015Z-0703-2022—terminated

The Lactobacillus acidophilus negative control (item 0243 single KWIK-STIK) contained in the 8164 Cepheid Xpert GBS QC Set and 8165 Cepheid Smart GBS QC Set was found to test positive for Group B Streptococcus (GBS) in some cases. This causes a failure when used as a quality control for the Cepheid Xpert GBS and Cepheid Smart GBS systems. The failure of the quality control test causes a disruption for the testing laboratory which may result in repeated testing or the need for alternative test methods. This recall is applicable to the 8164 and 8165 sets only.

Jul 17, 2015Z-0788-2022—completed

LYFO Disk Catalog #0983L is to contain Candida tropicalis. However, lot number 983-40-3 under Catalog #0983L, labeled as Candida tropicalis, is actually Yersinia entercolitica. This labeling error may cause a user's quality control to fail, resulting in testing needing to be repeated and delayed test results.

Oct 6, 2014Z-0714-2022—terminated

This strain should be resistant to high levels of Gentamicin and be resistant to Gentamicin Synergy. A specific lot was found susceptible to Gentamicin Synergy during in-house testing.

Oct 6, 2014Z-0712-2022—terminated

This strain should be resistant to high levels of Gentamicin and be resistant to Gentamicin Synergy. A specific lot was found susceptible to Gentamicin Synergy during in-house testing.

Oct 6, 2014Z-0713-2022—terminated

This strain should be resistant to high levels of Gentamicin and be resistant to Gentamicin Synergy. A specific lot was found susceptible to Gentamicin Synergy during in-house testing.

Mar 25, 2013Z-0641-2022—terminated

Some of the KWIK-STIK Catalog #01023P Campylobacter coli, Lot# 1023-05-7, contained an inner label stating the product is Catalog #0919K Haemophilus influenza. The organism has been confirmed to be C. coli, indicating this is a labeling error and the organism is the correct organism.

Feb 11, 2013Z-1021-2013—terminated

Microbiologics Inc is initiating a voluntary recall on products KWIK-QC Acid Fast Stain Slide, SL42-10 and KWIK-QC Mycobacterium, SL43-10. These products are being recalled because the control organisms are not properly fixated on the slide, which may cause the user to unintentionally contaminate the patient area of the slide by flooding the control well with stain. This contamination could pote

May 29, 2012Z-1936-2012—terminated

Microbiologics is recalling a number of lots of KWIK-QC Gram Stain Slides. This product gram negative control organism (E.coli) is not properly fixated on the slide, which may cause the user to unintentionally contaminate the patient area of the slide by flooding the control well with stain. This contamination could potentially lead to misdiagnosis and improper treatment of a patient.

Oct 12, 2007Z-0456-2008—terminated

Mislabeled: DuoPacks of Proteus vulgaris contained Listeria monocytogenes instead of the labeled Proteus vulgaris.