Catalogue
20g Tsuneoka Irr Chopper Du-02317 Ref Du-02317
MST .8mm Straight Phaco Tip 30 Deg PT-28130-1 Ref PT-28130-1
TrabEx Pro 600050-01 Ref 600050-01
MST/Dewey .9mm Ph Tip 0deg Bent PT-27400 Ref PT-27400
20g Olson Style Irrigating Chopper Du-02303 Ref Du-02303
Efekan SMILE Hook SML-0001 Ref SML-0001
MST/Packard A1 .7mm 12° Bent Phaco Tip, 45° PT-32245 Ref PT-32245
MST A1 .9mm Straight Phaco Tip, 45° Bevel PT-34145 Ref PT-34145
Phaco Tip MST 1.1mm 0 Deg Bent PT-27700 Ref PT-27700
MST/Dewey 0.9 Bent Mini A1 12° 30° PT-32030-R Ref PT-32030-R
BRT V2 Bent, Cap Pl, 0.3 A1 0.7 Gold BRT-1029-G Ref BRT-1029-G
21g Irrigating Nucleus Rotator Du-02328 Ref Du-02328
Phaco Tip MST 1.1mm A1 45deg, Bent PT-21745 Ref PT-21745
Phaco Tip MST 0.9mm Bent A1 0d PT-21200-1 Ref PT-21200-1
MST Dewey Mini A1 Bent Ph Tip 30deg PT-30430-1 Ref PT-30430-1
Yellow Sleeve Packard 0.7 Wrench SPK-0014-1 Ref SPK-0014-1
MST/Packard A1 .7mm 12° Bent Phaco Tip, 30° PT-32230-G-1 Ref PT-32230-G-1
BRT V2 Bnt, Cp Pl 0.3, 1.1 mini blu BRT-1005 Ref BRT-1005
MST/Packard .7mm Bent P Tip 30° PT-31830-GRN Ref PT-31830-GRN
MST/Dewey .9mm A1 Phaco Tip 0deg PT-22000 Ref PT-22000
MST/Packard .7mm Bent Phaco Tip Reverse Bevel PT-32630-Y Ref PT-32630-Y
Phaco Tip MST 1.1mm A1 30deg Str. PT-21630-1 Ref PT-21630-1
MST 0.9mm Straight Phaco Tip 30° PT-27930-YNS Ref PT-27930-YNS
MST Gold Silicone Sleeve and MST plastic wrench SPK-0004-1 Ref SPK-0004-1
MST/Packard .7mm Straight Phaco Tip Dewey 30° PT-32430-YNS Ref PT-32430-YNS
23g MST Tissue Grasper Forceps DFH-0014 Ref DFH-0014
MST/Dewey .9mm A1 Bent Ph Tip 15de PT-22115 Ref PT-22115
BRT V2 Cvd, Cp Pl 0.3, 1.1 mini blu BRT-1006 Ref BRT-1006
MST/Dewey 0.9mm Mini A1 Bent Ph Tip 45deg PT-30945 Ref PT-30945
MST/Packard A1 .7mm Phaco Tip Bent Dewey 30° PT-33230-G Ref PT-33230-G
Lindstrom / Duet Tri-port Irr Du-02339 Ref Du-02339
20g Curved Aspiration .3mm Port Du-02302 Ref Du-02302
BRT V2 Straight, Cap Pl 0.3, 0.7 Gold BRT-1033-G Ref BRT-1033-G
MST/Packard .7mm Straight P Tp Dewey 30° PT-32430-GRN Ref PT-32430-GRN
MST/Dewey .9mm A1 Bent Ph Tip 0de PT-22100 Ref PT-22100
22g Agarwal Microphacoknit Irr Chpr Du-02353 Ref Du-02353
MST/Packard .7mm Bent Phaco Tip Dewey 45° PT-32545-G-1 Ref PT-32545-G-1
MST/Packard .7mm Bent Phaco Tip 30° PT-31830-GNS Ref PT-31830-GNS
MST Mini S2 Phaco Tip 45° PT-30845 Ref PT-30845
Accutome Surgical AF0125 Ref AF0125
MST/Packard .7mm Straight Phaco Tip Dewey 30° PT-32430-Y Ref PT-32430-Y
MST A1 .9mm 20° Bent Phaco Tip, 45° Bevel PT-34345-1 Ref PT-34345-1
Showing 301-350 of 910
FDA recalls
2025
- 20 Aug 2025 Z-0411-2026 Class II Ongoing An ophthalmic knife has a suction set (not direct patient-contacting), which contains springs contaminated with an unidentified residue that may potentially cause eye irritation
2024
- 17 Sep 2024 Z-0521-2025 Class II Ongoing Due to pin coming off of handles.
FDA establishments
- Microsurgical Technology, Inc. Redmond, WA · US FEI 3019924
What MicroSurgical Technology Inc. makes
MicroSurgical Technology Inc. manufactures surgical instruments and devices for ophthalmic procedures, including the Malyugin Ring System for cataract surgery and the Trabectome and TrabEx+ for glaucoma management. These tools are designed for minimally invasive eye surgeries, such as trabeculectomy and phacoemulsification.
The company’s portfolio includes devices classified as Class IIa and Class IIb under EU regulations, with products listed in the eudamed database. The company is based in the United States.
Frequently asked questions
How many devices does MicroSurgical Technology Inc. have in the registry?
The registry currently lists 910 devices for MicroSurgical Technology Inc.. Devices recorded under merged duplicate company entries are counted once.
Are there FDA recall records for MicroSurgical Technology Inc.?
FDA recall records list 2 recalls initiated by MicroSurgical Technology Inc., the most recent initiated on 2025-08-20. 2 of them are recorded as ongoing. A recall is often a precaution started by the manufacturer; the records say nothing about the company's overall record.
Which FDA establishments are linked to MicroSurgical Technology Inc.?
1 FDA establishment is linked to MicroSurgical Technology Inc. in the registry; they are listed on the company page.
Information
- Address
- 8415 154TH AVE NE, REDMOND, United States
- Website
- www.microsurgical.com
- facebook.com/microsurgical
- [email protected]
- Phone
- 425-284-9409
- PRRC contact
- Farha Shafi Ahmed
- EUDAMED SRN
- US-MF-000020475
- DUNS number
- 097824130