Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

OMNIlife science, Inc.

United States·US-MF-000015882

Last updated September 17, 2026

Information

Country
United States
Address
480, Paramount Drive, Raynham, United States
LinkedIn
—
Facebook
—
Phone
—
PRRC Contact
Christina Rovaldi
EUDAMED SRN
US-MF-000015882
FDA FEI Number
3013682146
DUNS Number
—

Catalogue (3452)

Page 9 of 70
DeviceModel / ReferenceRegistriesClassStatus
APEX Knee System EP-24418
FDA UDI
Class IIActive
APEX Knee System EC-36024
FDA UDI
Class IIActive
APEX Revision Knee KC-52504
FDA UDI
Class IIActive
APEX PS Knee KP-22512
FDA UDI
Class IIActive
APEX Knee System KS-94316
FDA UDI
Class IActive
APEX Knee System EC-36062
FDA UDI
Class IIActive
OMNI K1 Hip HC-00050
FDA UDI
Class IIActive
Unity Knee System CK-72459
FDA UDI
Class IActive
MobiliT™ Cup CH-72282
FDA UDI
Class IActive
APEX PS Knee KP-0220R
FDA UDI
Class IIActive
APEX Knee System EP-24218
FDA UDI
Class IIActive
APEX Knee System KT-0425L-01
FDA UDI
Class IActive
APEX Knee System KS-95418
FDA UDI
Class IActive
APEX Knee System KS-99210
FDA UDI
Class IActive
APEX Knee System KS-67033
FDA UDI
Class IActive
OMNI Hip 303299
FDA UDI
Class IIActive
OMNI Hip H3-52804
FDA UDI
Class IIActive
APEX Knee System KS-66021R
FDA UDI
Class IActive
APEX Knee System KC-1155L-HP
FDA UDI
Class IIActive
APEX Knee System KS-99015
FDA UDI
Class IActive
OMNIBotics NS-52900
FDA UDI
Class IActive
APEX Knee System KR-51150
FDA UDI
Class IActive
APEX Knee System KS-67043
FDA UDI
Class IActive
APEX Knee System KR-40000
FDA UDI
Class IActive
APEX Knee System XK-5024L
FDA UDI
Class IActive
APEX Knee System X804-01
FDA UDI
Class IActive
OMNI Hip 100001
FDA UDI
Class IIActive
OMNI Knee KC-36019
FDA UDI
Class IIActive
APEX Knee System GM-03061-09
FDA UDI
Class IActive
APEX Knee System KR-51160
FDA UDI
Class IActive
APEX Knee System KC-36033
FDA UDI
Class IIActive
APEX Knee System KS-66021
FDA UDI
Class IActive
OMNI K1 Hip HC-00035
FDA UDI
Class IIActive
APEX Knee System WS-2114L-M
FDA UDI
Class IActive
APEX Knee System KS-95411
FDA UDI
Class IActive
APEX Knee System KS-90019
FDA UDI
Class IActive
APEX Knee System XK-06328
FDA UDI
Class IActive
APEX Knee System KR-42245
FDA UDI
Class IActive
APEX Knee System KR-50190
FDA UDI
Class IActive
APEX Knee System XK-10095
FDA UDI
Class IActive
APEX Knee System WS-10026
FDA UDI
Class IActive
APEX Knee System KR-71316
FDA UDI
Class IActive
APEX Knee System X580-2R
FDA UDI
Class IActive
APEX Knee System XK-00161
FDA UDI
Class IActive
APEX Knee System EP-22620
FDA UDI
Class IIActive
APEX Knee System KS-62003
FDA UDI
Class IActive
APEX Knee System KC-55181
FDA UDI
Class IIActive
APEX Knee System XK-06401-05
FDA UDI
Class IActive
APEX Knee System KS-1455L
FDA UDI
Class IActive
APEX Knee System WS-20075
FDA UDI
Class IActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (47)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

DateRecall No.ClassStatusReason
Oct 1, 2021Z-0237-2022—terminated

The device is missing grit blasting on the proximal surface of the femoral stem, which may lead to the possibility of product revision in the event of undersizing.

Dec 21, 2020Z-0922-2021—terminated

Acetabular Liners have a higher than acceptable oxidation limit, potential for patients to experience a higher wear rate for acetabular liners and require a revision surgery

Dec 21, 2020Z-0921-2021—terminated

Acetabular Liners have a higher than acceptable oxidation limit, potential for patients to experience a higher wear rate for acetabular liners and require a revision surgery

Dec 21, 2020Z-0920-2021—terminated

Acetabular Liners have a higher than acceptable oxidation limit, potential for patients to experience a higher wear rate for acetabular liners and require a revision surgery

Sep 11, 2019Z-0169-2020—terminated

Stems missing porous coating on the device.

Jul 23, 2019Z-2479-2019—terminated

Acetabular liners failed the oxidation testing performed prior to release. They may experience a higher wear rate, leading to revision surgery.

Jul 23, 2019Z-2481-2019—terminated

Acetabular liners failed the oxidation testing performed prior to release. They may experience a higher wear rate, leading to revision surgery.

Jul 23, 2019Z-2480-2019—terminated

Acetabular liners failed the oxidation testing performed prior to release. They may experience a higher wear rate, leading to revision surgery.

Apr 12, 2019Z-1717-2019—terminated

The OMNIBotics iBlock Cutting Guide does not lock onto the iBlock Saw Guide as intended and may loosen during use.

Nov 29, 2018Z-0837-2019—terminated

There is a potential for the inner pin of the handle to become loose and fall out.

May 18, 2018Z-2540-2018—terminated

The Internal packaging, the pouch and patient labels are improperly labeled.

Nov 20, 2017Z-1117-2018—terminated

The Apex Knee System Tibial Baseplate identified has an improper expiration date marked on the external packaging. The improper expiration date (2202-03) is marked on the external packaging only. The correct lot number (2022-03) is present in the internal packaging and sterile batch documentation.

Oct 14, 2016Z-0610-2017—terminated

Incorrect lot number on outer kit

Jun 9, 2015Z-2455-2015—terminated

The markings on both versions of the OFFSET FEMORAL ALIGNMENT GUIDES are incorrect. Specifically, the markings on the alignment guides are reversed from the intended position that should provide proper alignment for the offset revision stems when used with the femur.

Jun 9, 2015Z-2454-2015—terminated

The markings on both versions of the OFFSET FEMORAL ALIGNMENT GUIDES are incorrect. Specifically, the markings on the alignment guides are reversed from the intended position that should provide proper alignment for the offset revision stems when used with the femur.

Jun 4, 2015Z-2445-2015—terminated

The device may have improper screw hole placement due to inaccurate location of the index line.

Jun 3, 2015Z-2064-2015—terminated

Product may breach the inner and outer sterile pouches during shipping or handling.

May 9, 2014Z-2241-2014—terminated

Staining on hip implant.

Aug 9, 2012Z-2373-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Aug 9, 2012Z-2374-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Aug 9, 2012Z-2371-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Aug 9, 2012Z-2372-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Aug 9, 2012Z-2370-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Aug 9, 2012Z-2375-2012—terminated

The Apex Knee System Modular Tibia Augment may breach the inner and outer sterile pouches, compromising the sterility

Jul 10, 2009Z-1988-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1969-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1972-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1984-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1986-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1975-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1987-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1973-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1983-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1978-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1985-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1971-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1967-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1980-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1968-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1976-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1966-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1981-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1982-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1974-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1970-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1979-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.

Jul 10, 2009Z-1977-2009—terminated

The APEX Hip System Bipolar Head implant may not properly capture the femoral head assembly of the bipolar head onto the femoral head.