Shimadzu Corporation Medical Systems Division
JapanFDA applicant, unverified FDA FEI 3002808139
- Devices
- 2
- Registrations
- FDA
- FDA recalls
- 66 ongoing
At a glance
Market reach
- United States
- FDA FEI, FDA recalls
What Shimadzu Corporation Medical Systems Division makes
Shimadzu Corporation Medical Systems Division manufactures the Trinias, a cardiac monitoring system designed for continuous, real-time electrocardiogram (ECG) recording, and the SET-5002, a portable ECG device for ambulatory patient monitoring.
The company’s devices are classified as Class II under FDA regulations and are listed via the 510(k) pathway. The manufacturer is based in the United States.
Catalogue
Company details
- FDA FEI number
- 3002808139
- Address
- 1,NISHINOKYO KUWABARA-CHO, KYOTO
FDA recalls
FDA recall records list 6 recalls initiated by Shimadzu Corporation Medical Systems Division, the earliest on 2023-04-10 and the most recent on 2025-10-16. By recorded status: 6 ongoing. The reasons filed fall into these groups: labeling or instructions for use, software or firmware, mechanical integrity and manufacturing or quality process. A recall is often a precaution started by the manufacturer, and a count of records is not a verdict on a company.
Recalls initiated per year
- 2017 0
- 2018 0
- 2019 0
- 2020 0
- 2021 0
- 2022 0
- 2023 1
- 2024 4
- 2025 1
- 2026 0
2025
- 16 Oct 2025 Z-0499-2026 Class II Ongoing Due to an issue (potential breakage) with the shaft for the mounting of the X-ray tube assembly that could potentially result assembly coming off the rotating shaft.
Full distribution text
- 16 Oct 2025 Z-0499-2026 Class II Ongoing Due to an issue (potential breakage) with the shaft for the mounting of the X-ray tube assembly that could potentially result assembly coming off the rotating shaft.
2024
- 6 Sep 2024 Z-0139-2025 Class II Ongoing If digital angiography system is used with a specific catheterization table and the operator directs simultaneous movement of the table and the C-arm using direct memory, then direct memory button is released, the table may continue to move, which the operator can stop by pressing the stop button.
- 6 Sep 2024 Z-0316-2025 Class II Ongoing X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lead to the possibility of delay or cancellation of the examination.
Full distribution text
- 6 Sep 2024 Z-0317-2025 Class II Ongoing X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lead to the possibility of delay or cancellation of the examination.
Full distribution text
- 29 Jan 2024 Z-1292-2024 Class II Ongoing Due to capacitor manufacturing issue, their is a potential that Flat Panel Device may have abnormal display or no function.
2023
- 10 Apr 2023 Z-2270-2023 Class II Ongoing Eight fixing bolts at the base of the X-ray ceiling tube column assembly may be loose or missing so service is required to install a cable, bracket, and label behind the bracket, indicating when service is required, to eliminate the risk of the device falling.
Frequently asked questions
How many devices does Shimadzu Corporation Medical Systems Division have in the registry?
The registry currently lists 2 devices for Shimadzu Corporation Medical Systems Division. Devices recorded under merged duplicate company entries are counted once.
Which registries list Shimadzu Corporation Medical Systems Division's devices?
Among its 2 most recently registered devices, Shimadzu Corporation Medical Systems Division has devices listed in FDA 510(k) (2 devices).
What risk classes do Shimadzu Corporation Medical Systems Division's devices fall under?
Among its 2 most recently registered devices, the classes recorded for Shimadzu Corporation Medical Systems Division's devices are Class II. Each device page shows its own class and authorisation.
Are there FDA recall records for Shimadzu Corporation Medical Systems Division?
FDA recall records list 6 recalls initiated by Shimadzu Corporation Medical Systems Division, the most recent initiated on 16 Oct 2025. 6 of them are recorded as ongoing. A recall is often a precaution started by the manufacturer; the records say nothing about the company's overall record.
What are the newest devices from Shimadzu Corporation Medical Systems Division in the registry?
The most recently registered devices listed for Shimadzu Corporation Medical Systems Division include Trinias and SET-5002.