Ventlab Corp.

United States·US-MF-000008625

Last updated May 23, 2026

What Ventlab Corp. makes

Ventlab Corp. manufactures single-use manual pulmonary resuscitators, anaesthesia face masks, and anaesthesia breathing circuits. The company also produces non-ventilatory atomizers, non-powered airway pressure monitors, exhaled-gas oesophageal intubation detectors, single-use microbial medical gas filters, and basic nasal oxygen cannulas.

The company is based in the United States, and its portfolio consists of Class I and Class II medical devices. These products are listed within the FDA UDI database.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

Where is Ventlab Corp. based?

Ventlab Corp. is based in the United States. This location is confirmed by the company's official regulatory profile, which identifies the US as its primary base of operations.

What types of medical devices does Ventlab Corp. manufacture?

Ventlab Corp. manufactures a range of respiratory and anaesthesia equipment. Their product portfolio includes manual pulmonary resuscitators, anaesthesia face masks, anaesthesia breathing circuits, non-ventilatory atomizers, non-powered airway pressure monitors, exhaled-gas oesophageal intubation detectors, microbial medical gas filters, and basic nasal oxygen cannulas.

How are the devices from Ventlab Corp. classified?

The medical devices produced by Ventlab Corp. are classified as Class I and Class II. These classifications are based on the regulatory framework applied to the specific types of respiratory and anaesthesia equipment the company manufactures.

Which registries list the devices produced by Ventlab Corp.?

The devices manufactured by Ventlab Corp. are listed in the FDA UDI database. This registry is the official source for identifying the company's medical devices as required by regulatory standards.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
United States
Address
2710 Northridge Dr. NW, Suite A, Grand Rapids, United States
Website
myairlife.com
LinkedIn
—
Facebook
—
Phone
+1-269-873-0502
PRRC Contact
Robert Yamashita
EUDAMED SRN
US-MF-000008625
FDA FEI Number
—
DUNS Number
—

Catalogue (1040)

Page 19 of 21
DeviceModel / ReferenceRegistriesClassStatus
Ventlab SC200
FDA UDI
Class IIActive
Ventlab HS4051-C
FDA UDI
Class IIUnknown
Ventlab FH603005
FDA UDI
Class IIActive
Ventlab AF1002MBP
FDA UDI
Class IIActive
Ventlab HCS4566
FDA UDI
Class IIActive
Ventlab BT2216
FDA UDI
Class IActive
Ventlab 2101F
FDA UDI
Class IActive
Ventlab AFW1140MB
FDA UDI
Class IIActive
Ventlab AF3140MCP
FDA UDI
Class IIActive
Ventlab 3025
FDA UDI
Class IUnknown
Ventlab AF3140MB-PW
FDA UDI
Class IIActive
Ventlab FH603003CFT
FDA UDI
Class IIUnknown
Ventlab AF5140MBS-P
FDA UDI
Class IIActive
Ventlab VN3104MCFB-M01
FDA UDI
Class IIActive
Ventlab BT2434
FDA UDI
Class IActive
Ventlab 2200F
FDA UDI
Class IActive
Ventlab AF1140MB-E
FDA UDI
Class IIActive
Ventlab 2201F
FDA UDI
Class IActive
Ventlab PRO-6053
FDA UDI
Class IIActive
Ventlab AF1040MBN
FDA UDI
Class IIActive
Ventlab VN2000MB-D234
FDA UDI
Class IIActive
Ventlab VN3100MB
FDA UDI
Class IIActive
Ventlab HS4051-R2
FDA UDI
Class IIUnknown
Ventlab VR6500-20
FDA UDI
Class IActive
Ventlab AF2102MC-PT
FDA UDI
Class IIActive
Ventlab 1001HZ
FDA UDI
Class IIActive
Ventlab 4114F
FDA UDI
Class IIActive
Ventlab BT4045
FDA UDI
Class IActive
Ventlab 4210F
FDA UDI
Class IIActive
Ventlab 2301F
FDA UDI
Class IActive
Ventlab FH603023
FDA UDI
Class IIActive
Ventlab HS4154
FDA UDI
Class IIActive
Ventlab HS34011
FDA UDI
Class IIUnknown
Ventlab AF5140MC
FDA UDI
Class IIActive
Ventlab BF102
FDA UDI
Class IIActive
Ventlab AF5140MBPW-D5
FDA UDI
Class IIActive
Ventlab AF2140MB-N
FDA UDI
Class IIActive
Ventlab VR3900-20
FDA UDI
Class IActive
Ventlab AF3000MB
FDA UDI
Class IIActive
Ventlab AF1040MB-S5
FDA UDI
Class IIActive
Ventlab AF5140MB-IT
FDA UDI
Class IIActive
Ventlab HS4151-MZ
FDA UDI
Class IIUnknown
Ventlab VN5000MX-F
FDA UDI
Class IIActive
Ventlab AF2100MB
FDA UDI
Class IIActive
Ventlab VN4100MCP
FDA UDI
Class IIActive
Ventlab HS4051-M00-1-2Z
FDA UDI
Class IIUnknown
Ventlab VR5100-20
FDA UDI
Class IActive
Ventlab AF1003MB
FDA UDI
Class IIActive
Ventlab HCS4565
FDA UDI
Class IIActive
Ventlab AFM5140MC-D5G10
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

No authorised representatives on record.

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (21)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Ventlab Corp. has 21 recall records initiated between April 15, 2003, and March 15, 2016, all of which are currently in terminated status. The reasons cited for these recalls include issues with pop-off valve functionality, potential separation of the breathing bag from the bushing, non-functional CO2 indicators, missing instructions regarding manometer verification, device cracking, and potential volume leakage through the inlet valve.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Mar 15, 2016Z-1880-2016—terminated

Stat-check CO2 indicators are non-functional. The indicator is yellow when not in use and should be purple when not in use. The yellow indicates a 5% CO2 level, cardiac massage and ventiliation being performed correctly. The color will not change during use and will not be an indicator of CO2 level or improper performance of cardiac message and ventilation.

May 16, 2014Z-1948-2014—terminated

The pop-off valve in the defective devices remain open and a squeeze of the bag may not generate enough force to force the duck bill valve open and therefore no air will be delivered to the victim.

Jul 11, 2012Z-0177-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0172-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0176-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0179-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0174-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0180-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0175-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0170-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0173-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0181-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0171-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Jul 11, 2012Z-0178-2013—terminated

Possible volume leakage through the inlet valve during compressions of the resuscitator bag.

Dec 5, 2007Z-2324-2008—terminated

During setup and potentially during procedures, the breathing bag can become separated from the taped bushing that is part of the breathing bag assembly.

Mar 26, 2004Z-0892-04—terminated

In some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

Mar 26, 2004Z-0893-04—terminated

In some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

Mar 26, 2004Z-0891-04—terminated

In some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

Mar 26, 2004Z-0894-04—terminated

In some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

Mar 26, 2004Z-0895-04—terminated

In some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

Apr 15, 2003Z-0982-03—terminated

Printed bag with instructions to verify the pressure with a 'certified manometer' was omitted in some of the product.