Is this your brand? Sign in to claim ownership.

Sign in to claim this brand

Vortex Surgical, Inc.

United States·US-MF-000022888

Last updated May 24, 2026

What Vortex Surgical, Inc. makes

Vortex Surgical, Inc. manufactures single-use ophthalmic surgical instruments, including vitrectomy handpieces and cannulas for fluid and gas management, laser beam guides for ophthalmic procedures, and soft-tissue manipulation tools such as forceps and probes. Their portfolio also includes epiretinal/inner limiting membrane scrapers, fibreoptic light instruments, and laser-compatible probes designed for intraocular and retinal surgeries. Additional offerings encompass procedure kits for intraocular injections and illuminated depressors for surgical visualization.

The company’s devices are classified under FDA regulations as Class I, Class II, and Class IIa, with corresponding entries in the FDA’s Unique Device Identifier (UDI) database and the EU’s eudamed registry. These products are intended for use in the United States and European markets, adhering to applicable regulatory standards for surgical and diagnostic ophthalmic instruments.

Written from this company's registered devices by an AI model, and not verified by a human reviewer.

Frequently asked questions

What types of medical devices does Vortex Surgical, Inc. manufacture?

Vortex Surgical, Inc. specializes in single-use ophthalmic surgical instruments. Their product portfolio includes vitrectomy fluid/gas handling handpieces and cannulas, laser beam guides for ophthalmic procedures, and various soft-tissue manipulation tools like forceps and probes. They also produce epiretinal/inner limiting membrane scrapers, fibreoptic light instruments, and laser-compatible probes. Additionally, they offer procedure kits for intraocular injections and illuminated depressors, all designed for retinal and intraocular surgeries.

Where is Vortex Surgical, Inc. based, and where are their devices listed in regulatory registries?

Vortex Surgical, Inc. is based in the United States. Their devices are listed in two key regulatory registries: the FDA’s Unique Device Identifier (UDI) database and the EU’s eudamed registry. These listings ensure transparency and compliance with regulatory requirements in both the U.S. and European markets.

How are the devices manufactured by Vortex Surgical, Inc. classified under FDA regulations?

The devices produced by Vortex Surgical, Inc. are classified under three categories of FDA regulations: Class I, Class II, and Class IIa. This classification is determined by the level of risk associated with each device, with Class IIa representing a moderate risk that requires special controls to ensure safety and effectiveness. The classification helps guide regulatory oversight and compliance requirements.

What kinds of ophthalmic surgical procedures are Vortex Surgical, Inc.’s devices intended for?

Vortex Surgical, Inc.’s devices are primarily intended for ophthalmic surgical procedures, particularly those involving the retina and intraocular space. This includes vitrectomy procedures (where fluid and gas are managed), laser-assisted surgeries (where beam guides and probes are used), and manipulations of soft tissues like the inner limiting membrane or retinal detachment repairs. Their single-use instruments are designed to enhance precision and reduce infection risk in these delicate procedures.

AI-generated from registry data and not verified by a human reviewer.

Information

Country
United States
Address
4, Research Park Dr, Saint Charles, United States
LinkedIn
—
Facebook
—
Phone
6367784350
PRRC Contact
Andrew Ritts
EUDAMED SRN
US-MF-000022888
FDA FEI Number
—
DUNS Number
080375891

Catalogue (176)

Page 1 of 4
DeviceModel / ReferenceRegistriesClassStatus
25ga Embrace Elevator Box of 5 VS0370.25
EUDAMED
Class IIaActive
Versatile Soft Tip 23ga
FDA UDI
Class IActive
Retractable ILM Elevator 23ga
FDA UDI
Class IActive
I² Kit for intraocular injection VS0510
FDA UDI
Class IActive
20ga Bending Laser Probe - Alcon Compatible VS0140.20A
FDA UDI
Class IIActive
Vortex Surgical Inc VS0640.25-XEX
FDA UDI
Class IActive
Vortex Surgical Inc VS0743.25
FDA UDI
Class IActive
Vortex Surgical Inc VS0742.23
FDA UDI
Class IActive
Vortex Surgical Inc VS0802
FDA UDI
Class IActive
Vortex Surgical Inc VS0225C
FDA UDI
Class IActive
25ga Curved Laser Probe VS0120.25
FDA UDI
Class IIActive
TID - Todorich Illuminated Depressor VS0800
FDA UDI
Class IActive
Vortex Surgical Inc VS0644.25-FXX
FDA UDI
Class IActive
Vortex Surgical Inc. VS0803
FDA UDI
Class IIActive
Vortex Surgical Inc VS0740.23
FDA UDI
Class IActive
Vortex Surgical Inc VS0202.27
FDA UDI
Class IActive
Vortex Surgical Inc VS0350.25
FDA UDI
Class IActive
Vortex Surgical Inc VS0640.25-FEX
FDA UDI
Class IActive
Vortex Surgical Inc VS0201.27
FDA UDI
Class IActive
25ga Bending Laser Probe - Iridex Compatible VS0140.25I
FDA UDI
Class IIActive
25ga Flexible Tapered Laser Probe - Alcon Compatible VS0130.25A
FDA UDI
Class IIActive
23ga Bending Laser Probe - Alcon Compatible VS0140.23A
FDA UDI
Class IIActive
27ga Straight Laser Probe VS0110.27
FDA UDI
Class IIActive
Vortex Surgical Inc VS0280.23
FDA UDI
Class IActive
Vortex Surgical Inc VS0205.25B
FDA UDI
Class IActive
Vortex Surgical Inc VS0744.27-35
FDA UDI
Class IActive
Vortex Surgical Inc VS0743.25-35
FDA UDI
Class IActive
Vortex Surgical Inc VS0640.23-XEX
FDA UDI
Class IActive
Vortex Surgical Inc VS0205.25
FDA UDI
Class IActive
27ga Soft Tip Cannula VS0200.27
FDA UDI
Class IActive
27ga Curved Laser Probe VS0120.27
FDA UDI
Class IIActive
23ga Soft Tip Cannula VS0200.23
FDA UDI
Class IActive
Vortex Surgical Inc. VS0753.27
FDA UDI
Class IActive
Vortex Surgical Inc VS0800
FDA UDI
Class IActive
Vortex Surgical Inc. VS0125.25
FDA UDI
Class IIActive
Vortex Surgical Inc VS0520
FDA UDI
Class IActive
Vortex Surgical Inc VS0350.23
FDA UDI
Class IActive
25ga Flexible Tapered Laser Probe - Iridex Compatible VS0130.25I
FDA UDI
Class IIActive
Vortex Surgical Inc VS0280.25
FDA UDI
Class IActive
Vortex Surgical Inc VS0743.23
FDA UDI
Class IActive
Vortex Surgical Inc VS0640.23-XXS
FDA UDI
Class IActive
Vortex Surgical Inc VS0290
FDA UDI
Class IActive
Vortex Surgical Inc. VS0390
FDA UDI
Class IActive
Vortex Surgical Inc VS0742.25
FDA UDI
Class IActive
Vortex Surgical Inc VS0220.25
FDA UDI
Class IActive
27ga Curved Laser Probe - Iridex Compatible VS0120.27I
FDA UDI
Class IIActive
ACTU8 Adaptive Forceps 25ga
FDA UDI
Class IActive
Vortex Surgical Inc VS0200.25
FDA UDI
Class IActive
Vortex Surgical Inc VS0713.25
FDA UDI
Class IActive
23ga Flexible Tapered Laser Probe - Alcon Compatible VS0130.23A
FDA UDI
Class IIActive

Related Companies

Authorised Representatives

Importers

Not available yet.

Notified Bodies

Not available yet.

Authorities

Not available yet.

FDA Recalls (15)

Recalls reported by this firm to the FDA. Listed at company level — FDA recall records don't identify a specific catalogue device.

Vortex Surgical, Inc. has 15 recall records listed in the FDA database, initiated between December 18, 2023, and December 16, 2025. The recalls include open, classified, and terminated statuses, with reasons involving potential voids in sterile pouches, smoothness issues with certain products during cannula passage, and residue found on forceps tips linked to specific lots.

AI-generated summary of the recall records listed below. It describes what the records state and is not an assessment of this manufacturer.

DateRecall No.ClassStatusReason
Dec 16, 2025Z-1246-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1253-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1255-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1244-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1245-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1249-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1248-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1250-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1254-2026—open, classified

XXX

Dec 16, 2025Z-1251-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1247-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1256-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Dec 16, 2025Z-1252-2026—open, classified

There may be voids located in the seal of Tyvek pouches associated with identified catalog numbers and lots. A compromised sterile barrier has potential of bioburden contamination which could lead to infection.

Nov 19, 2025Z-1004-2026—open, classified

Reason for the voluntary recall is some products in this lot are not passing through a 25ga cannula smoothly.

Dec 18, 2023Z-0970-2024—terminated

Reason for the voluntary recall is residue was identified on the two forceps tips of a customer in Korea. The residue is associated with one lot of forceps tips which were utilized in two lots of ACTU8 Adaptive Forceps Tips occurring in 0.25% of those lots.