Skip to content

1.5T GEM Anterior Array

by GE Healthcare Coils

Ref 5391442Model 1.5T GEM Coil Suite

1.5T GEM Anterior Array (5391442) is a MRI system coil (EU MDR Class I; FDA Class II) made by GE Healthcare Coils, registered in EUDAMED on 16 Feb 2024 (Basic UDI-DI 8406821BUG00176HJ), cleared under FDA 510(k) K103335 on 7 Mar 2011 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682118491), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K103335

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00176HJ Basic UDI-DI 00840682118491UDI-DIDate16 Feb 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682118491 UDI-DI Date1 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK103335 Date7 Mar 2011DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 29 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00176HJ registered 16 Feb 2024 Active
  • FDA 510(k) K103335 decided 7 Mar 2011 Active
  • FDA GUDID UDI-DI 00840682118491 listed 1 Aug 2016 Listed

Recalls

3 recalls · FDA

    • Terminated Z-1533-2014 FDA Class II initiated 23 Apr 2014

    GE Healthcare has recently become aware of a potential safety issue with certain GE MRI Products. Patient egress from the system can be delayed or impeded if the cradle release handle and/or cradle release block mechanism malfunctions or becomes misaligned. This could make the safe removal of the patient from the system difficult.

    • Terminated Z-1480-2014 FDA Class II initiated 2 Apr 2014

    Potential safety issue with gradient coil electromechanical connections associated with GE MR Products. Gradient coil electromechanical connections may loosen causing an increase in resistance. The increased resistance can lead to increasing heat during scanning which, in turn, can cause material in the Rear Endbell enclosure to overheat, generate smoke in the scan room, and cause some localize

    • Terminated Z-1492-2012 FDA Not yet classified initiated 12 Apr 2012

    GE Healthcare is conducting a recall on Optima MR450W with GEM. During scanning of a patient, if an improperly torqued gradient connection exists, it may cause the gradient lead to produce excessive heat. If a second and compounding issue of improperly routed Rear Pedestal Air Supply Hose is also present, routed in such a way to cause the hose to come in contact with the overheated gradient lead

Timeline

6 dated events

  1. Cleared FDA 510(k) K103335
  2. Recall initiated FDA recalls Z-1492-2012
  3. Recall initiated FDA recalls Z-1480-2014
  4. Recall initiated FDA recalls Z-1533-2014
  5. Listed FDA GUDID 00840682118491
  6. Registered EUDAMED 8406821BUG00176HJ

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
MRI system coil, radio-frequency
Device name
1.5T GEM Coil Suite
Model / reference
1.5T GEM Coil Suite EUDAMED
5391442 EUDAMED
1.5T GEM ANTERIOR ARRAY GUDID
Primary DI / UDI-DI
00840682118491
Basic UDI-DI
8406821BUG00176HJ
510(k) Number
FDA product code
MOS, LNH
EMDN code
Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
GMDN term
MRI system coil, radio-frequency
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.1000
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
1.5T GEM Coil Suite
5391442
GUDID
1.5T GEM ANTERIOR ARRAY
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000001664
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.

Other devices from GE Healthcare Coils

See all devices from GE Healthcare Coils →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)