10V4 Transducer 11014579
by Siemens Medical Solutions USA, Inc.
Ref 11014579Model MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_11014579
10V4 Transducer 11014579 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 21 Sep 2026 (Basic UDI-DI 0405686902435VQ), cleared under FDA 510(k) K193257 on 31 Jan 2020 (1 earlier submission) and listed in FDA GUDID since 30 Sep 2019 (UDI-DI 04056869052076), active as of 24 Oct 2026.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686902435VQ 04056869052076 | Date21 Sep 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK193257 | Date31 Jan 2020 | StatusActive |
| United States | GUDID listing GUDID | Number04056869052076 | Date30 Sep 2019 | StatusListed |
Official records
- EUDAMED public site 0405686902435VQ
- AccessGUDID record 04056869052076
- FDA 510(k) database K193257
- FDA 510(k) database K191922
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686902435VQ registered 21 Sep 2026 Active
- FDA 510(k) K193257 decided 31 Jan 2020 Active
- FDA GUDID UDI-DI 04056869052076 listed 30 Sep 2019 Listed
Recalls
-
- Ongoing Z-1330-2021
The ultrasound system averages the Mean Sac Diameter (MSD) and Gestational Sac Diameter (GSD) into the Estimated Date of Delivery (EDD) calculation. This may result in an incorrect EDD, which may influence patient management decisions regarding induction of labor and elective caesarean delivery, which may result in premature births.
Timeline
- Cleared FDA 510(k) K191922
- Listed FDA GUDID 04056869052076
- Cleared FDA 510(k) K193257
- Recall initiated FDA recalls Z-1330-2021
- Registered EUDAMED 0405686902435VQ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 10V4 Transducer
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- MDR_07_IIA_IQH_BTS Lb A_ACDV_10V4_11014579
- Model / reference
- 11014579, MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_11014579
- Primary DI / UDI-DI
- 04056869052076
- Basic UDI-DI
- 0405686902435VQ
- FDA product code
- ITX
- EMDN code
- Z110402010301 Transcutaneous ultrasound sector probes (phased array), two–dimensional
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under TRANSCUTANEOUS ULTRASOUND SECTOR PROBES (PHASED ARRAY), TWO–DIMENSIONAL.
- P 2-9 120000039 by Esaote S.p.A.
- 6Sc-D H46462LS by GE Healthcare Japan Corporation
- PA023E 9600153000 by Esaote S.p.A.
- 5P1 Transducer 9077 by BK MEDICAL APS
- P11-3 P29671-21 by Fujifilm Sonosite, Inc.
- P11-3 P29671-21A by Fujifilm Sonosite, Inc.
- HUMANSCAN 5327197-2 500395 by Humanscan Company, Ltd.
- S11 04573596212233 by FUJIFILM CORPORATION
- 4Sc-RS H48062AU by GE Medical Systems CO. Ltd
- HUMANSCAN 5327196-2 500395 by Humanscan Company, Ltd.