9C3 Transducer 11575182
by Siemens Medical Solutions USA, Inc.
Ref 11575182Model MDR_07_IIA_IQH_BTS LB A_ACDV_9C3_11575182
9C3 Transducer 11575182 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 21 Sep 2026 (Basic UDI-DI 0405686902431VG), cleared under FDA 510(k) K210743 on 1 Apr 2021 (4 earlier submissions) and listed in FDA GUDID since 22 Jun 2021 (UDI-DI 04056869284569), active as of 25 Oct 2026.
Active
Valid until
No date given
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686902431VG 04056869284569 | Date21 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04056869284569 | Date22 Jun 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK210743 | Date1 Apr 2021 | StatusActive |
Official records
- EUDAMED public site 0405686902431VG
- AccessGUDID record 04056869284569
- FDA 510(k) database K210743
- FDA 510(k) database K201462
- FDA 510(k) database K193257
- FDA 510(k) database K191922
- FDA 510(k) database K180067
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686902431VG registered 21 Sep 2026 Active
- FDA 510(k) K210743 decided 1 Apr 2021 Active
- FDA GUDID UDI-DI 04056869284569 listed 22 Jun 2021 Listed
Recalls
-
- Ongoing Z-3216-2024
If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliters using multiplier 100 instead of 1000, resulting values 10x smaller than actual, which could contribute misdiagnosis or negatively influence patient management
-
- Ongoing Z-1600-2024
On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will display the LAST measured value, not min or max, which could contribute to patient condition misdiagnosis or negatively influence patient management decisions.
-
- Ongoing Z-2582-2023
If a user-generated preset for an 18L6 transducer created on a 1.0 ultrasound system is used with a 2.0 ultrasound system, the 2.0 ultrasound system will display underestimated measurement results when using an 18L6 transducer and viewing in the Dual format visualization function, which may lead to misdiagnosis of a patient's condition or influence patient management decisions in a negative way.
-
- Ongoing Z-0547-2022
Due to a calculation error in the measurement when using 2D trace (manual trace) tool. The trace circumference value is overestimated and may potentially result in misdiagnosis of a patient's condition.
-
- Ongoing Z-1330-2021
The ultrasound system averages the Mean Sac Diameter (MSD) and Gestational Sac Diameter (GSD) into the Estimated Date of Delivery (EDD) calculation. This may result in an incorrect EDD, which may influence patient management decisions regarding induction of labor and elective caesarean delivery, which may result in premature births.
Timeline
- Cleared FDA 510(k) K193257
- Cleared FDA 510(k) K201462
- Recall initiated FDA recalls Z-1330-2021
- Cleared FDA 510(k) K210743
- Listed FDA GUDID 04056869284569
- Recall initiated FDA recalls Z-0547-2022
- Recall initiated FDA recalls Z-2582-2023
- Recall initiated FDA recalls Z-1600-2024
- Recall initiated FDA recalls Z-3216-2024
- Registered EUDAMED 0405686902431VG
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 9C3 Transducer
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- MDR_07_IIA_IQH_BTS Lb A_ACDV_9C3_11575182
- Model / reference
- 11575182, MDR_07_IIA_IQH_BTS LB A_ACDV_9C3_11575182
- Primary DI / UDI-DI
- 04056869284569
- Basic UDI-DI
- 0405686902431VG
- FDA product code
- ITX
- EMDN code
- Z110402010201 Curvilinear transcutaneous two–dimensional ultrasound probes (convex–array)
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under CURVILINEAR TRANSCUTANEOUS TWO–DIMENSIONAL ULTRASOUND PROBES (CONVEX–ARRAY).
- Convex probe 6MC by CHISON Medical Technologies Co., Ltd.
- 5C1e Transducer 9085 by BK MEDICAL APS
- HUMANSCAN 5505701 500395 by Humanscan Company, Ltd.
- C35 04573596211373 by FUJIFILM CORPORATION
- SC3121 122000900 by Esaote S.p.A.
- C60XI/5-2 MHZ P24538-02 by Fujifilm Sonosite, Inc.
- C2-6b-D A7MP by KONICA MINOLTA, INC.
- C60XI/5-2 MHZ P20402-11A by Fujifilm Sonosite, Inc.
- C251 04573596211335 by FUJIFILM CORPORATION
- C1-5-RS H40462LA by GE Healthcare Japan Corporation