3.0T 8CH HD Torso Array
Ref 2415410Model 3.0T 8CH HD Torso Array
3.0T 8CH HD Torso Array (2415410) is a MRI system coil (EU MDR Class I; FDA Class II; FDA product code MOS, Coil, magnetic resonance, specialty) made by GE Healthcare Coils, registered in EUDAMED on 11 Apr 2024 (Basic UDI-DI 8406821BUG00360HD), cleared under FDA 510(k) K030371 on 5 May 2003 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682108614), active as of 22 Oct 2026.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00360HD 00840682108614 | Date11 Apr 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00840682108614 | Date1 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK030371 | Date5 May 2003 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00360HD
- AccessGUDID record 00840682108614
- FDA 510(k) database K030371
From the FDA record
- Device description
- 3T 8CH TORSO HDMR2
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00360HD registered 11 Apr 2024 Active
- FDA 510(k) K030371 decided 5 May 2003 Active
- FDA GUDID UDI-DI 00840682108614 listed 1 Aug 2016 Listed
Recalls
-
- Terminated Z-0849-04
A defective capacitor in the Body Array Coil may result in unstable, unreliable performance, with excessive heating of patient's body.
Timeline
- Cleared FDA 510(k) K030371
- Recall initiated FDA recalls Z-0849-04
- Listed FDA GUDID 00840682108614
- Registered EUDAMED 8406821BUG00360HD
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- MRI system coil, radio-frequency
- Model / Ref / Catalog
- 3.0T 8CH HD Torso Array, 2415410
- Primary DI / UDI-DI
- 00840682108614
- Basic UDI-DI
- 8406821BUG00360HD
- 510(k) Number
- FDA product code
- MOS
- EMDN code
- Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
- GMDN term
- MRI system coil, radio-frequency
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 892.1000
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000001664
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.
- Vanguard for Siemens Breast MRI Auxiliary Table 300007108971 by Philips Medical Systems Nederland B.V.
- dS MSK S 1.5T by Philips Healthcare (Suzhou) Co., Ltd.
- Philips dS Base 3.0T 459801290092 by Philips Ds North America LLC
- Philips 4522-133-17141 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- 1.5T Receive-Only 16ch Flex SPEEDER Medium NC042200 by NEOCOIL, LLC
- Philips 4598-000-51951 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- Philips dS FootAnkle 16Ch 3.0T 459801295501 by Philips Ds North America LLC
- dS TorsoCardiac 1.5T 459801681991 by Philips Healthcare (Suzhou) Co., Ltd.
- Vanguard Breast MRI Table 453530385162 by Philips Medical Systems Nederland B.V.
- 3.0T 16ch Breast Coil by NEOCOIL, LLC