3.0T GEM Anterior Array
Ref 5391454Model 3.0T GEM Suite
3.0T GEM Anterior Array (5391454) is a MRI system coil (EU MDR Class I; FDA Class II; FDA product code LNH, System, nuclear magnetic resonance imaging) made by GE Healthcare Coils, registered in EUDAMED on 19 Feb 2024 (Basic UDI-DI 8406821BUG00308HB), cleared under FDA 510(k) K103327 on 30 Sep 2011 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682102483), active as of 22 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00308HB 00840682102483 | Date19 Feb 2024 | StatusActive |
| United States | GUDID listing GUDID | Number00840682102483 | Date1 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK103327 | Date30 Sep 2011 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00308HB
- AccessGUDID record 00840682102483
- FDA 510(k) database K103327
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00308HB registered 19 Feb 2024 Active
- FDA 510(k) K103327 decided 30 Sep 2011 Active
- FDA GUDID UDI-DI 00840682102483 listed 1 Aug 2016 Listed
Recalls
-
- Terminated Z-0127-2021
Potential electrical arc flash within the Power Gradient & RF (PGR) Cabinet.
-
- Terminated Z-2131-2016
GE Healthcare has recently become aware of a potential safety issue with the patient bore heating on the Discovery MR750w. A small area on the bore surface, which is normally accessible to the patient, can get warm enough to cause a serious burn in the event the patient touches the bore and proper padding is not used. No injury has been reported to GE as a result of this issue.
-
- Terminated Z-1533-2014
GE Healthcare has recently become aware of a potential safety issue with certain GE MRI Products. Patient egress from the system can be delayed or impeded if the cradle release handle and/or cradle release block mechanism malfunctions or becomes misaligned. This could make the safe removal of the patient from the system difficult.
-
- Terminated Z-1480-2014
Potential safety issue with gradient coil electromechanical connections associated with GE MR Products. Gradient coil electromechanical connections may loosen causing an increase in resistance. The increased resistance can lead to increasing heat during scanning which, in turn, can cause material in the Rear Endbell enclosure to overheat, generate smoke in the scan room, and cause some localize
-
- Terminated Z-2266-2013
GE Healthcare has recently become aware of a potential safety issue due to non-unique series identifiers embedded in image headers of certain GE MR Products. For ClariView and Screen Save from GVTK (Gems Visualization ToolKit) Viewer, the MR Product can generate image headers with non-unique series identifiers, which when exported to some PACS systems, results in the series being associated wit
-
- Terminated Z-1100-2013
GE Healthcare has recently become aware of a potential issue due to image flip in frequency encoding direction associated with a specific workflow of your Discovery MR750w system. Image flip issue in frequency encoding direction (including S/I, A/P and R/L) can result in incorrect localization of anatomy and pathological findings.
Timeline
- Cleared FDA 510(k) K103327
- Recall initiated FDA recalls Z-1100-2013
- Recall initiated FDA recalls Z-2266-2013
- Recall initiated FDA recalls Z-1480-2014
- Recall initiated FDA recalls Z-1533-2014
- Recall initiated FDA recalls Z-2131-2016
- Listed FDA GUDID 00840682102483
- Recall initiated FDA recalls Z-0127-2021
- Registered EUDAMED 8406821BUG00308HB
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- MRI system coil, radio-frequency
- Device name
- 3.0T GEM Suite
- Model / Ref / Catalog
- 3.0T GEM Suite, 5391454, 3.0T GEM Anterior Array
- Primary DI / UDI-DI
- 00840682102483
- Basic UDI-DI
- 8406821BUG00308HB
- 510(k) Number
- FDA product code
- LNH
- EMDN code
- Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
- GMDN term
- MRI system coil, radio-frequency
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 892.1000
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 3.0T GEM Suite 5391454 | 3.0T GEM Anterior Array |
| Device class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000001664
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.
- Philips 4522-133-17172 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- Philips 4522-133-17191 by SHANGHAI CHENGUANG MEDICAL TECHNOLOGIES CO, LTD
- 1.5T 32Ch Cardiac Coil - Anterior 300007281491 by Philips Medical Systems Nederland B.V.
- 3.0T 32Ch Cardiac Coil - Anterior 300007289581 by Philips Medical Systems Nederland B.V.
- Pediatric SPEEDER Stabilizer NC036200 by NEOCOIL, LLC
- NA 1.5T 4CH LARGE FLEX COIL by GE HEALTHCARE(TIANJIN) COMPANY LIMITED
- 3.0T 16ch Shoulder Coil NC143202 by NEOCOIL, LLC
- 1.5T 4ch Small Flex Coil 5430692 by GE HEALTHCARE(TIANJIN) COMPANY LIMITED
- dS MSK M 1.5T by Philips Healthcare (Suzhou) Co., Ltd.
- 1.5T GP Flex Coil 2320288 by GE Medical Systems, LLC