Skip to content

3.0T HD Breast Array

by GE Healthcare Coils

Ref 2415544Model 1.5T and 3.0T HD Breast Arrays

3.0T HD Breast Array (2415544) is a MRI system coil (EU MDR Class I; FDA Class II; FDA product code MOS, Coil, magnetic resonance, specialty) made by GE Healthcare Coils, registered in EUDAMED on 25 Oct 2023 (Basic UDI-DI 8406821BUG00359HU), cleared under FDA 510(k) K052585 on 4 Oct 2005 and listed in FDA GUDID since 1 Aug 2016 (UDI-DI 00840682103756), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

5 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K052585

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00359HU Basic UDI-DI 00840682103756UDI-DIDate25 Oct 2023RegisteredStatusActive
United StatesGUDID listing GUDID Number00840682103756 UDI-DI Date1 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK052585 Date4 Oct 2005DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 27 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00359HU registered 25 Oct 2023 Active
  • FDA 510(k) K052585 decided 4 Oct 2005 Active
  • FDA GUDID UDI-DI 00840682103756 listed 1 Aug 2016 Listed

Recalls

5 recalls · FDA

  • 3 recalls, same reason

    • Terminated Z-0516-2007 FDA Unclassified (pre-2012) initiated 31 Jan 2007 on shared 510(k) K052585
    • Terminated Z-0517-2007 FDA Unclassified (pre-2012) initiated 31 Jan 2007 on shared 510(k) K052585
    • Terminated Z-0518-2007 FDA Unclassified (pre-2012) initiated 31 Jan 2007 on shared 510(k) K052585

    The packaging used for the Breast Biopsy plate may exhibit small holes or tears

  • 2 recalls, same reason

    • Terminated Z-0519-2007 FDA Unclassified (pre-2012) initiated 31 Jan 2007 on shared 510(k) K052585
    • Terminated Z-0505-2007 FDA Unclassified (pre-2012) initiated 21 Nov 2006 on shared 510(k) K052585

    The packaging used for the Breast Biopsy plate may exhibit small holes or tears.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

8 dated events

  1. Cleared FDA 510(k) K052585
  2. Recall initiated FDA recalls Z-0505-2007
  3. Recall initiated FDA recalls Z-0516-2007
  4. Recall initiated FDA recalls Z-0517-2007
  5. Recall initiated FDA recalls Z-0519-2007
  6. Recall initiated FDA recalls Z-0518-2007
  7. Listed FDA GUDID 00840682103756
  8. Registered EUDAMED 8406821BUG00359HU

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
MRI system coil, radio-frequency
Device name
1.5T and 3.0T HD Breast Arrays
Model / Ref / Catalog
1.5T and 3.0T HD Breast Arrays, 2415544, 3.0T HD BREAST ARRAY
Primary DI / UDI-DI
00840682103756
Basic UDI-DI
8406821BUG00359HU
510(k) Number
FDA product code
MOS
EMDN code
Z1105018001 Magnetic resonance (MR) radiofrequency surface coils
GMDN term
MRI system coil, radio-frequency
Device class
Class I EUDAMED
Class II GUDID
Regulation number
892.1000
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
1.5T and 3.0T HD Breast Arrays
2415544
GUDID
3.0T HD BREAST ARRAY
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000001664
Authorised representative
GE Medical Systems SCS FR-AR-000000344

Similar devices in this category

Other devices filed under MAGNETIC RESONANCE (MR) RADIOFREQUENCY SURFACE COILS.

Other devices from GE Healthcare Coils

See all devices from GE Healthcare Coils →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)