Skip to content

6 Channel Body Coil

by Siemens Medical Systems, Inc.

510(k) K023571

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK023571 Date20 Nov 2002ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
MOS
Device Class
Class II
Regulation
21 CFR Part 892.1000
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 26 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The 6 Channel Body Coil is a magnetic resonance specialty coil designed for imaging applications. It functions as an anterior general flexible receiving coil featuring six signal channels and six integrated preamplifiers to facilitate high-speed imaging of the trunk.

This device is intended for use in abdomen, pelvis, cardiac, and thorax applications and is compatible with iPAT imaging technology. It is designed for combination with the posterior CP Spine Array coil and does not require coil tuning.

Other devices from Siemens Medical Systems USA, Inc.

See all devices from Siemens Medical Systems USA, Inc. →

Questions

AI-generated answers, 26 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary function of the 6 Channel Body Coil?

    This device is a magnetic resonance specialty coil designed for imaging applications. It functions as an anterior general flexible receiving coil that facilitates high-speed imaging of the trunk.

  • Which clinical applications is this coil intended for?

    The coil is intended for use in abdomen, pelvis, cardiac, and thorax imaging applications.

  • Does the coil require manual tuning before use?

    No, the 6 Channel Body Coil does not require coil tuning, which simplifies the setup process for the clinician.

  • Can this coil be used with other imaging hardware?

    Yes, this device is designed to be used in combination with the posterior CP Spine Array coil and is compatible with iPAT imaging technology.