ABL800 Flex with Flexq Module, Model ABL8XX

by Radiometer Medical ApS

510(k) K043218

ABL800 Flex with Flexq Module, Model ABL8XX is a medical device (FDA Class II; FDA product code CHL, Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph) made by Radiometer Medical ApS, cleared under FDA 510(k) K043218 on 10 May 2005, active as of 11 Oct 2026. One FDA recall is linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 11 Oct 2026.

Regulatory status

as of registry sync 11 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK043218 Date10 May 2005ClearedStatusActive

Official records

From the FDA record

Received by the FDA
22 Nov 2004
FDA decision
10 May 2005 (Substantially Equivalent)
FDA review time
169 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K043218 (openFDA), as read on 11 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

3 recalls · FDA

    • Terminated Z-2303-2013 FDA Class II initiated 8 Oct 2012 on shared 510(k) K043218

    RADIOMETER became aware that some membranes may have enzyme residue on the outer membrane. The enzyme residue may cause an initial negative bias on the reported Lactate result upon replacement of the Lactate membrane.

    • Terminated Z-2571-2011 FDA Unclassified (pre-2012) initiated 7 Apr 2011 on shared 510(k) K043218

    Based on internal testing and user/customer complaint reports received, the firm determined that wrinkles may arise on the outer membrane of the calcium membrane units upon installation. Retention of fluids between the wrinkles can cause a positive bias resulting in calcium measuring errors. This situation poses a risk to the safety of patients, particularly when the measurement results are used

    • Terminated Z-0705-2007 FDA Unclassified (pre-2012) initiated 16 Jan 2007

    In some situations pre-registered patient data is not reset when leaving the pre-registration mode in the software. This occurs when a Safe Pico blood sampler associated with a specific patient is pre-registered in the analyzer by scanning a barcode.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K043218
  2. Recall initiated FDA recalls Z-0705-2007
  3. Recall initiated FDA recalls Z-2571-2011
  4. Recall initiated FDA recalls Z-2303-2013

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CHL
Device class
Class II
Regulation
21 CFR Part 862.1120
Advisory committee
Clinical Chemistry
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code CHL (Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph).

Other devices from Radiometer Medical ApS

See all devices from Radiometer Medical ApS →