ABL8X7 Flex

by Radiometer Medical ApS

510(k) K051968

ABL8X7 Flex is a medical device (FDA Class II; FDA product code CGL, Electrode, Ion Based, Enzymatic, Creatinine) made by Radiometer Medical ApS, cleared under FDA 510(k) K051968 on 16 Oct 2006, active as of 10 Oct 2026. 3 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 10 Oct 2026.

Regulatory status

as of registry sync 10 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK051968 Date16 Oct 2006ClearedStatusActive

Official records

From the FDA record

Received by the FDA
20 Jul 2005
FDA decision
16 Oct 2006 (Substantially Equivalent)
FDA review time
453 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K051968 (openFDA), as read on 10 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

4 recalls · FDA

    • Terminated Z-0801-2019 FDA Class II initiated 2 Jul 2018 on shared 510(k) K051968

    From three incidents in Denmark and Sweden, comparison studies on patient blood samples carried out for quality assurance demonstrated that creatinine measurements as determined on analyzers could be underestimated with up to 28% as compared with measurements from COBAS. The underestimated creatinine occurs specifically, when measurements on Autocheck 6+ level 1 (also known as S7835 Autocheck module and abbreviated AC6+L1) are less than or equal to 230 micro-meter of a specified insert interval for AC6+L1 with insert limits 210 290 micro-meter. Ultimately, a lower read-out on patient samples is observed Customers are concerned about underestimation of creatinine results in patients, which are to undergo radiocontrast x-ray investigations. If these patients are not healthy, the exposure of radiocontrast agents may induce kidney insufficiency (contrast-induced nephropathy). Hazardous situation: Underestimation of the concentration of creatinine.

    • Terminated Z-1293-2015 FDA Class II initiated 29 Oct 2014

    Negative drift on QC during in-use lifetime of CREA membranes can be observed.

    • Terminated Z-1008-2012 FDA Unclassified (pre-2012) initiated 16 Dec 2011

    When the user activates the dosicap (containing the crea additive) and mounts it onto the bottle, the threads will not seal correctly causing approximately 10% of the solution to leak out when the bottle is placed horizontally for dissolving the additive. This will cause the concentration of creatinin and creatin in the calibration solution to be wrong, and results in a bias on the Crea results.

    • Terminated Z-1015-2010 FDA Unclassified (pre-2012) initiated 26 Mar 2009

    Analysis of customer data, (for ABL 8X7 customers) has shown that the reference membranes are out of analytical specifications when replaced as specified in the device labeling. These errors in analytical specifications could lead to inadequate or clinical interventions (therapy) or misleading interpretation of patient status in clinical settings.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K051968
  2. Recall initiated FDA recalls Z-1015-2010
  3. Recall initiated FDA recalls Z-1008-2012
  4. Recall initiated FDA recalls Z-1293-2015
  5. Recall initiated FDA recalls Z-0801-2019

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CGL
Device class
Class II
Regulation
21 CFR Part 862.1225
Advisory committee
Clinical Chemistry
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code CGL (Electrode, Ion Based, Enzymatic, Creatinine).

Other devices from Radiometer Medical ApS

See all devices from Radiometer Medical ApS →