ABL90 Flex Plus

by Radiometer Medical ApS

510(k) K160153

ABL90 Flex Plus is a medical device (FDA Class II; FDA product code CHL, Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph) made by Radiometer Medical ApS, cleared under FDA 510(k) K160153 on 4 Nov 2016, active as of 11 Oct 2026. 4 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 11 Oct 2026.

Regulatory status

as of registry sync 11 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK160153 Date4 Nov 2016ClearedStatusActive

Official records

From the FDA record

Received by the FDA
22 Jan 2016
FDA decision
4 Nov 2016 (Substantially Equivalent)
FDA review time
287 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K160153 (openFDA), as read on 11 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

5 recalls · 3 ongoing · FDA

    • Ongoing Z-1659-2025 FDA Class II initiated 21 Mar 2025

    ABL90 FLEX and ABL90 FLEX PLUS analyzers running with Radiometer Windows 10 versions RWIN10 1.0 and RWIN10 1.1 may unexpectedly freeze (the analyzer ceases to operate) during a sample measurement. The analyzer software includes a feature (watchdog) that detects a freeze and automatically restarts the software to continue operating the analyzer. However, even if a restart occurs, any sample being processed at that time will be lost, potential to lead to delay in test results.

  • 2 recalls, same reason

    • Ongoing Z-1858-2021 FDA Class II initiated 14 Apr 2021 on shared 510(k) K160153
    • Ongoing Z-1857-2021 FDA Class II initiated 14 Apr 2021

    Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed.

    • Terminated Z-1761-2020 FDA Class II initiated 3 Feb 2020

    The firm received reports of occurrences where the barcode reader misinterpreted the contents of a locally printed barcode label used for entering patient ID or accession number into the analyzer in connection with a sample measurement. This could result is patient mixup and/or lost of sample, resulting in delayed medical treatment.

    • Terminated Z-2138-2020 FDA Class II initiated 21 Nov 2019

    The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcomponent of the optical system which measures ctHb and derivates. In a cuvette with light shunt, some of the received light has not been transmitted through the sample. This will lead to a perturbed and non-linear absorbance spectrum which results in measurement errors.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K160153
  2. Recall initiated FDA recalls Z-2138-2020
  3. Recall initiated FDA recalls Z-1761-2020
  4. Recall initiated FDA recalls Z-1858-2021
  5. Recall initiated FDA recalls Z-1857-2021
  6. Recall initiated FDA recalls Z-1659-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CHL
Device class
Class II
Regulation
21 CFR Part 862.1120
Advisory committee
Clinical Chemistry
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code CHL (Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph).

Other devices from Radiometer Medical ApS

See all devices from Radiometer Medical ApS →