AccuSITE™ Needle Guide 610-2338

by Civco Medical Instruments Co., Inc.

AccuSITE Needle Guide 610-2338 is a needle guide (FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., cleared under FDA 510(k) K093713 on 19 Jan 2010 and listed in FDA GUDID since 21 Jan 2021 (UDI-DI 10841436120019), active as of 23 Oct 2026. 7 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K093713

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10841436120019 UDI-DI Date21 Jan 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK093713 Date19 Jan 2010DecidedStatusActive

Official records

From the FDA record

Device description
Sterile needle guide (20ga) with (14x147cm) CIV-flex cover with Enviision saline wipe
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K093713 decided 19 Jan 2010 Active
  • FDA GUDID UDI-DI 10841436120019 listed 21 Jan 2021 Listed

Recalls

7 recalls · 1 ongoing · FDA

    • Ongoing Z-1892-2025 FDA Class II initiated 1 May 2025

    During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.

    • Terminated Z-2888-2018 FDA Class II initiated 23 Feb 2018

    A cover failed leak testing during validation testing of new needle guides from a replacement tool.

  • 5 recalls, same reason

    • Terminated Z-0286-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0287-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0288-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0289-2016 FDA Class II initiated 21 Oct 2015
    • Terminated Z-0290-2016 FDA Class II initiated 21 Oct 2015

    Sterility of the product cannot be assured.

Timeline

9 dated events

  1. Cleared FDA 510(k) K093713
  2. Recall initiated FDA recalls Z-0286-2016
  3. Recall initiated FDA recalls Z-0287-2016
  4. Recall initiated FDA recalls Z-0288-2016
  5. Recall initiated FDA recalls Z-0289-2016
  6. Recall initiated FDA recalls Z-0290-2016
  7. Recall initiated FDA recalls Z-2888-2018
  8. Listed FDA GUDID 10841436120019
  9. Recall initiated FDA recalls Z-1892-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
AccuSITE™ Needle Guide
Generic name
Needle guide, single-use
Model / Ref / Catalog
610-2338
Primary DI / UDI-DI
10841436120019
510(k) Number
FDA product code
ITX
GMDN term
Needle guide, single-use
Device class
Class II
Regulation number
892.1570
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide
Size
Length — 14 Centimeter
Width — 147 Centimeter

Similar devices in this category

Other devices filed under Needle guide, single-use.

Other devices from Civco Medical Instruments Co., Inc.

See all devices from Civco Medical Instruments Co., Inc. →

Properties

  • Supplied sterile
  • Sterilise before use
  • Single use
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (7, all answered No)