Biopsy Bracket 644-076
by Civco Medical Instruments Co., Inc.
Biopsy Bracket 644-076 is an ultrasound imaging system tracking positioner (FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Civco Medical Instruments Co., Inc., cleared under FDA 510(k) K093713 on 19 Jan 2010 and listed in FDA GUDID since 22 Aug 2017 (UDI-DI 00841436105927), active as of 23 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00841436105927 | Date22 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK093713 | Date19 Jan 2010 | StatusActive |
Official records
- AccessGUDID record 00841436105927
- FDA 510(k) database K093713
From the FDA record
- Device description
- Reusable non-sterile multi-angle bracket for use with Hitachi Aloka Medical L441 and UST-5415 transducers
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K093713 decided 19 Jan 2010 Active
- FDA GUDID UDI-DI 00841436105927 listed 22 Aug 2017 Listed
Recalls
-
- Ongoing Z-1892-2025
During the attachment of the needle guide to the covered probe, the tight tolerance and fit of the needle guide can cause a pinhole breach in the transducer cover when latching the guide in place.
-
- Terminated Z-2888-2018
A cover failed leak testing during validation testing of new needle guides from a replacement tool.
-
- Terminated Z-0286-2016
- Terminated Z-0288-2016
- Terminated Z-0289-2016
- Terminated Z-0290-2016
- Terminated Z-0287-2016
Sterility of the product cannot be assured.
Timeline
- Cleared FDA 510(k) K093713
- Recall initiated FDA recalls Z-0286-2016
- Recall initiated FDA recalls Z-0288-2016
- Recall initiated FDA recalls Z-0289-2016
- Recall initiated FDA recalls Z-0290-2016
- Recall initiated FDA recalls Z-0287-2016
- Listed FDA GUDID 00841436105927
- Recall initiated FDA recalls Z-2888-2018
- Recall initiated FDA recalls Z-1892-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Biopsy Bracket
- Generic name
- Ultrasound imaging system tracking positioner, reusable
- Model / Ref / Catalog
- 644-076
- Primary DI / UDI-DI
- 00841436105927
- 510(k) Number
- FDA product code
- ITX
- GMDN term
- Ultrasound imaging system tracking positioner, reusable
- Device class
- Class II
- Regulation number
- 892.1570
- GUDID distribution status
- In Commercial Distribution
- Size
- Length — 3.67 InchHeight — 1.68 Inch
Similar devices
Other devices filed under FDA product code ITX (Transducer, ultrasonic, diagnostic).
- 5.0 MHZ MERIDIAN ULTRASOUND IMAGING SYSTEM by Johnson & Johnson Professionals, Inc.
- COLOR VELOCITY IMAGING (CVI) OPTION FOR PLATINUM by Philips Medical Systems North America, Inc.
- MARK V DUPLEX ULTRASONIC SCAN SYS. by Advanced Technology Laboratories, Inc.
- SHEATHES NEEDLE GUIDE, MODEL NG-SR-A-484-KIT (THERE WILL BE VARIOUS MODEL NUMBERS BASED ON TRANSDUCER AND COVER) by Sheathing Technologies, Inc.
- Accuro® 3S Needle Guide Kit by Rivanna Medical, Inc.
- SHAPEABLE DOPPLER FLOW PROBE by Cook Vascular, Inc.
- ACUSON C366 TRANSDUCER by Acuson Corp.
- FUJIFILM B20BU by FUJIFILM CORPORATION
- GE B510 TRANSDUCER by GE MEDICAL SYSTEMS, INC.
- PSG(TM) 20 GUAGE DOPPLER NEEDLE by Peripheral Systems Group