Accutron Inc.
Ref 51975Model Digital Flowmeter
Accutron Inc. (51975) is an oxygen/air/nitrous oxide breathing gas mixer (EU MDD Class IIb; FDA Class II; FDA product code BSZ, Gas-Machine, Anesthesia) made by Accutron, registered in EUDAMED on 24 Mar 2026 (Basic UDI-DI B-00813830023329), cleared under FDA 510(k) K052335 on 23 Nov 2005 and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 00813830023329), active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00813830023329 00813830023329 | Date24 Mar 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00813830023329 | Date28 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK052335 | Date23 Nov 2005 | StatusActive |
Official records
- EUDAMED public site B-00813830023329
- AccessGUDID record 00813830023329
- FDA 510(k) database K052335
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI B-00813830023329 registered 24 Mar 2026 Active
- FDA 510(k) K052335 decided 23 Nov 2005 Active
- FDA GUDID UDI-DI 00813830023329 listed 28 Sep 2016 Listed
Recalls
-
- Terminated Z-0017-2013
- Terminated Z-0018-2013
- Terminated Z-0020-2013
- Terminated Z-0019-2013
Accutron is recalling the Flowmeter (Analgesia Gas Machine) because when it flows Nitrous Gas without Oxygen gas being turned on, it functions in an incorrect manner.
Timeline
- Cleared FDA 510(k) K052335
- Recall initiated FDA recalls Z-0017-2013
- Recall initiated FDA recalls Z-0018-2013
- Recall initiated FDA recalls Z-0020-2013
- Recall initiated FDA recalls Z-0019-2013
- Listed FDA GUDID 00813830023329
- Registered EUDAMED B-00813830023329
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Accutron Inc. EUDAMEDDigital Ultra Flowmeter GUDID
- Generic name
- Oxygen/air/nitrous oxide breathing gas mixer
- Model / Ref / Catalog
- Digital Flowmeter, 51975
- Primary DI / UDI-DI
- 00813830023329
- Basic UDI-DI
- B-00813830023329
- 510(k) Number
- FDA product code
- BSZ
- EMDN code
- Z1203010101 Anaesthesia devices
- GMDN term
- Oxygen/air/nitrous oxide breathing gas mixer
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 868.5160
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000009363
- Authorised representative
- Medical Technology Promedt Consulting GmbH DE-AR-000000085
Similar devices in this category
Other devices filed under ANAESTHESIA DEVICES.
- Prima 445 Anaesthetic Machine 5007370 by Penlon Limited
- Atlan A100 XL 8621200 by Drägerwerk AG & Co. KGaA
- Anesthesia System A8 by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- Carestation 750c A1 1012-9755-000 by Datex-Ohmeda Inc.
- Fabius MRI 8607300 by Drägerwerk AG & Co. KGaA
- Anesthesia System A5 by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- Prima 451 MRI Anaesthetic Machine 5011300 by Penlon Limited
- Carestation 650 A1 1012-9650-000 by Datex-Ohmeda Inc.
- Flow-i Anesthesia System, Flow-c Anesthesia System, Flow-e Anesthesia System by Maquet Critical Care AB
- Thornhill Research Inc. 124198 by Thornhill Research Inc