Acuson S2000 Diagnostic Ultrasound System

by Siemens Medical Solutions USA, Inc., Ultrasound DI 2 variants

510(k) K082142

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

8 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK082142 Date13 Nov 2008ClearedStatusActive

Recalls

8 recalls · FDA

    • Terminated Z-2051-2011 FDA Unclassified (pre-2012) initiated 15 Mar 2011

    The Firm discovered a software error on the Accuson S2000 ultrasound systems affecting the measurement results in the patient report.

    • Terminated Z-1837-2011 FDA Unclassified (pre-2012) initiated 17 Aug 2010 on shared 510(k) K082142

    There is an error in the estimation of mean pressure gradient in the Cardiac measurement package. The currently implemented calculation will result in an underestimation of the mean pressure gradient (PGmean) when estimated from a trace of the Doppler waveform of the stenotic flow.

  • 3 recalls, same reason

    • Terminated Z-1005-2011 FDA Unclassified (pre-2012) initiated 2 Oct 2009
    • Terminated Z-1006-2011 FDA Unclassified (pre-2012) initiated 2 Oct 2009 on shared 510(k) K082142
    • Terminated Z-1007-2011 FDA Unclassified (pre-2012) initiated 2 Oct 2009 on shared 510(k) K082142

    ECG waveform does not accurately align with 2D, M-Mode or Spectral Images.

    • Terminated Z-1392-2011 FDA Unclassified (pre-2012) initiated 28 Aug 2009 on shared 510(k) K082142

    If the transducer is not disconnected from the system after an automatic shutdown due to thermal limits being exceeded, then the next time it is used, the thermal safety guards do not take effect. Normally, the thermal limit before automatic image freeze (and therefore power shut off) occurs at 43 degrees Centigrade.

    • Terminated Z-1884-2011 FDA Unclassified (pre-2012) initiated 7 Apr 2009 on shared 510(k) K082142

    Device function failure--When performing a TEE exam with the transducer, CW (Continuous Wave) mode is not functional. Due to work flow, this may not be apparent until the transducer is inserted into the patient's esophagus.

    • Terminated Z-1900-2011 FDA Unclassified (pre-2012) initiated 14 Jan 2009 on shared 510(k) K082142

    The product has a software problem in which previous patient measurement data gets associated with another patient's image.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
IYN
Device Class
Class II
Regulation
21 CFR Part 892.1550
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent