Advantage Workstation 4.3.
510(k) K052995
Advantage Workstation 4.3. is a medical device (FDA Class II; FDA product code LLZ, System, Image Processing, Radiological) made by GE Healthcare, cleared under FDA 510(k) K052995 on 8 Nov 2005, active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK052995 | Date8 Nov 2005 | StatusActive |
Official records
- FDA 510(k) database K052995
From the FDA record
- Received by the FDA
- 25 Oct 2005
- FDA decision
- 8 Nov 2005 (Substantially Equivalent)
- FDA review time
- 14 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Recalls
-
- Terminated Z-0270-2014
GE Healthcare has recently become aware of a potential safety issue due to the image orientation within GSI viewer on AW products. The GSI Viewer application running on AW/Volume Share or on the AW Server when making a batch and rotating the batch group clockwise 180 degrees (Inferior to Superior) will display images in the Superior orientation. The orientation annotation on the image is correc
-
- Terminated Z-2203-2012
GE Healthcare is informing you of incorrect measurements when using the Aorta analysis protocol or customized protocols. Until a new software version is installed they are asking you not to use the aorta analysis protocol or the customized protocols for an aneurysm. A second issue was also discovered internally. When loading PET data into the Volume Viewer, if slices are missing in a PET serie
-
- Terminated Z-3012-2011
GE Healthcare has become aware that patient mismatch could occur on some Seno Advantage 2.1 and 2.2 Workstations with RIS CCOW integration. This issue may impact patient safety. When Seno Advantage workstation is synchronized with RIS using CCOW (an HL7 standard protocol designed to enable disparate applications to synchronize in real-time), the following issues could occur: 1. Two different
-
- Terminated Z-0265-2008
Aortic Length over-estimated: incorrect measurements when using the Aorta analysis protocol or customized protocols. Until a new software version is installed the aorta analysis protocol or the customized protocols for an aneurysm should NOT BE USED.
Timeline
- Cleared FDA 510(k) K052995
- Recall initiated FDA recalls Z-0265-2008
- Recall initiated FDA recalls Z-3012-2011
- Recall initiated FDA recalls Z-2203-2012
- Recall initiated FDA recalls Z-0270-2014
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- LLZ
- Device class
- Class II
- Regulation
- 21 CFR Part 892.2050
- Advisory committee
- Radiology
- FDA decision
- SESE Substantially Equivalent
Similar devices
Other devices filed under FDA product code LLZ (System, Image Processing, Radiological).
- EchoMD Automated Ejection Fraction Software by Bay Labs, Inc.
- ViewPoint 6 by Ge Medical Systems Ultrasound and Primary Care Dia
- VITREA ENDOVASCULAR STENT PLANNING SOFTWARE by Vital Images, Inc.
- SYNAPSE 3D COLON ANALYSIS by Fujifilm Medical System U.S.A., Inc.
- EzDent-i / E2 / Prora View/ Smart M Viewer by Ewoosoft Co., Ltd.
- Elements Image Fusion, Elements Cranial Distortion Correction, Elements Spine Curvature Correction, Elements TRAM by Brainlab AG
- GENTLE COLON (REVISION 2.0) by Rendoscopy, Inc.
- DG PACS by Dicom Grid, Inc.
- X-Clever (ASHK100G) by LG Electronics Inc.
- sterEOS Workstation by Eos Imaging, Inc.