Aespire View

by Datex-Ohmeda Inc.

Aespire View, an anaesthesia workstation (FDA Class II; FDA product code BSZ, Gas-machine, anesthesia) made by Datex-Ohmeda Inc., was cleared under FDA 510(k) K172045 on 3 Nov 2017 (1 earlier submission) and listed in FDA GUDID on 23 Sep 2015 (UDI-DI 00840682102285); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 24.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

22 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK172045 Date3 Nov 2017DecidedStatusActive
United StatesGUDID listing Number00840682102285 UDI-DI Date23 Sep 2015ListedStatusListed GUDID: not in commercial distribution

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K172045 decided 3 Nov 2017 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00840682102285 listed 23 Sep 2015 Listed

Recalls

24 recalls · 22 ongoing · FDA

  • 4 recalls, same reason

    • Ongoing Z-3191-2026 FDA Class II initiated 30 Jul 2026
    • Ongoing Z-3190-2026 FDA Class II initiated 30 Jul 2026
    • Ongoing Z-3189-2026 FDA Class II initiated 30 Jul 2026
    • Ongoing Z-3192-2026 FDA Class II initiated 30 Jul 2026

    Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue occurs, anesthetic agent delivery will be interrupted and requires clinician intervention. If this is not provided, the patient may experience decreased anesthetic agent effect.

  • 9 recalls, same reason

    • Ongoing Z-0082-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0080-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0078-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0084-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0074-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0077-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0075-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0081-2025 FDA Class I initiated 12 Jul 2024
    • Ongoing Z-0076-2025 FDA Class I initiated 12 Jul 2024

    Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port.

    • Ongoing Z-1427-2022 FDA Class II initiated 27 May 2022

    The base of the anesthesia system can have a crack and could potentially fracture resulting in a tip or overbalance of the anesthesia system. This can result in potential injury if it falls on a person.

  • 2 recalls, same reason

    • Ongoing Z-1285-2022 FDA Class II initiated 25 Apr 2022
    • Ongoing Z-1286-2022 FDA Class II initiated 25 Apr 2022

    Backup batteries can fail earlier than their estimated life.

  • 2 recalls, same reason

    • Ongoing Z-2596-2021 FDA Class II initiated 2 Aug 2021
    • Ongoing Z-2595-2021 FDA Class II initiated 2 Aug 2021

    The flow sensors built prior to June 2021 could have damaged tubes with small punctures or cuts that could cause leaks resulting in incorrect anesthesia machine tidal volumes potentially leading to over-delivery of volume to the patient.

  • 4 recalls, same reason

    • Ongoing Z-0314-2021 FDA Class II initiated 17 Sep 2020
    • Ongoing Z-0312-2021 FDA Class II initiated 17 Sep 2020
    • Ongoing Z-0313-2021 FDA Class II initiated 17 Sep 2020
    • Ongoing Z-0311-2021 FDA Class II initiated 17 Sep 2020

    Flow sensors could have damaged tubes in the form of small punctures or cuts.

    • Terminated Z-1389-2022 FDA Class I initiated 1 Jun 2022

    There is a potential reversal of the O2 and air cylinder pressure transducer connections.

    • Terminated Z-0677-2016 FDA Class II initiated 15 Dec 2015

    The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged pressure in the patient breathing circuit during ventilation potentially resulting in barotrauma.

Timeline

27 dated events

  1. Recall initiated FDA recalls Z-0084-2025
  2. Recall initiated FDA recalls Z-0074-2025
  3. Recall initiated FDA recalls Z-0077-2025
  4. Recall initiated FDA recalls Z-0075-2025
  5. Recall initiated FDA recalls Z-0081-2025
  6. Recall initiated FDA recalls Z-0076-2025
  7. Recall initiated FDA recalls Z-3191-2026
  8. Recall initiated FDA recalls Z-3190-2026
  9. Recall initiated FDA recalls Z-3189-2026
  10. Recall initiated FDA recalls Z-3192-2026

17 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Aespire
Generic name
Anaesthesia workstation, general-purpose
Model / reference
View
Primary DI / UDI-DI
00840682102285
510(k) Number
FDA product code
BSZ
GMDN term
Anaesthesia workstation, general-purpose
Device class
Class II
Regulation number
868.5160
GUDID distribution status
Not in Commercial Distribution
MRI safety
MR Unsafe

Similar devices

Other devices filed under FDA product code BSZ (Gas-machine, anesthesia).

Other devices from Datex-Ohmeda Inc.

See all devices from Datex-Ohmeda Inc. →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)