Aespire View
Aespire View, an anaesthesia workstation (FDA Class II; FDA product code BSZ, Gas-machine, anesthesia) made by Datex-Ohmeda Inc., was cleared under FDA 510(k) K172045 on 3 Nov 2017 (1 earlier submission) and listed in FDA GUDID on 23 Sep 2015 (UDI-DI 00840682102285); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 24.
Active
Valid until
No expiry
FDA recalls
22 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK172045 | Date3 Nov 2017 | StatusActive |
| United States | GUDID listing | Number00840682102285 | Date23 Sep 2015 | StatusListed |
Official records
- AccessGUDID record 00840682102285
- FDA 510(k) database K172045
- FDA 510(k) database K143530
From the FDA record
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K172045 decided 3 Nov 2017 Active
- FDA GUDID UDI-DI 00840682102285 listed 23 Sep 2015 Listed
Recalls
-
- Ongoing Z-3191-2026
- Ongoing Z-3190-2026
- Ongoing Z-3189-2026
- Ongoing Z-3192-2026
Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled or manual ventilation and initiates audible and visual alarms. When this issue occurs, anesthetic agent delivery will be interrupted and requires clinician intervention. If this is not provided, the patient may experience decreased anesthetic agent effect.
-
- Ongoing Z-0082-2025
- Ongoing Z-0080-2025
- Ongoing Z-0078-2025
- Ongoing Z-0084-2025
- Ongoing Z-0074-2025
- Ongoing Z-0077-2025
- Ongoing Z-0075-2025
- Ongoing Z-0081-2025
- Ongoing Z-0076-2025
Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port.
-
- Ongoing Z-1427-2022
The base of the anesthesia system can have a crack and could potentially fracture resulting in a tip or overbalance of the anesthesia system. This can result in potential injury if it falls on a person.
-
- Ongoing Z-1285-2022
- Ongoing Z-1286-2022
Backup batteries can fail earlier than their estimated life.
-
- Ongoing Z-2596-2021
- Ongoing Z-2595-2021
The flow sensors built prior to June 2021 could have damaged tubes with small punctures or cuts that could cause leaks resulting in incorrect anesthesia machine tidal volumes potentially leading to over-delivery of volume to the patient.
-
- Ongoing Z-0314-2021
- Ongoing Z-0312-2021
- Ongoing Z-0313-2021
- Ongoing Z-0311-2021
Flow sensors could have damaged tubes in the form of small punctures or cuts.
-
- Terminated Z-1389-2022
There is a potential reversal of the O2 and air cylinder pressure transducer connections.
-
- Terminated Z-0677-2016
The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or prolonged pressure in the patient breathing circuit during ventilation potentially resulting in barotrauma.
Timeline
- Recall initiated FDA recalls Z-0084-2025
- Recall initiated FDA recalls Z-0074-2025
- Recall initiated FDA recalls Z-0077-2025
- Recall initiated FDA recalls Z-0075-2025
- Recall initiated FDA recalls Z-0081-2025
- Recall initiated FDA recalls Z-0076-2025
- Recall initiated FDA recalls Z-3191-2026
- Recall initiated FDA recalls Z-3190-2026
- Recall initiated FDA recalls Z-3189-2026
- Recall initiated FDA recalls Z-3192-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Aespire
- Generic name
- Anaesthesia workstation, general-purpose
- Model / reference
- View
- Primary DI / UDI-DI
- 00840682102285
- FDA product code
- BSZ
- GMDN term
- Anaesthesia workstation, general-purpose
- Device class
- Class II
- Regulation number
- 868.5160
- GUDID distribution status
- Not in Commercial Distribution
- MRI safety
- MR Unsafe
Similar devices
Other devices filed under FDA product code BSZ (Gas-machine, anesthesia).
- CENTRALERT by Draeger Medical, Inc.
- AM1000 by Bear Medical Systems, Inc.
- Codonics Safe Labeling System-Point of Care Station (PCS) (SLS-700i and related 610i, 620i, 630i series enabled to retrofit RFID features); Codonics Safe Labeling System-Point of Care Station (PCS) (SLS-1, SLS XXX, Multiple Models Pending Configuration) by Codonics.Incorporated
- MIE FALCON, DATEX ENGSTROM FLEXIMA II by Medical and Industrial Equipment
- HP ORVUE INTRA-OP (M2510A) by Hewlett-Packard Co.
- Flowmeter, Digital Flushmount, Biewer 27076-BWR by ACCUTRON
- MATRX MDM, RA by Matrx Medical, Inc.
- Flow-i Anesthesia System C20, C30, C40 by Maquet Critical Care AB
- PERSEUS A500 by Draeger Medical, Inc.
- GE DATEX-OHMEDA S/5 ADU CARESTATION by GE Healthcare Finland Oy