Ameritus AEG-100P-80

by Kentec Medical, Inc. 2 variants

Ameritus AEG-100P-80 is a nasogastric/orogastric tube (FDA Class II; FDA product code FPD, Tube, Feeding) made by Kentec Medical, Inc., cleared under FDA 510(k) K100526 on 22 Apr 2010 and listed in FDA GUDID since 9 Aug 2016 (UDI-DI 10817522011820), active as of 23 Oct 2026. 9 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

9 closed

Documents

510(k) K100526

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10817522011820 UDI-DI Date9 Aug 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK100526 Date22 Apr 2010DecidedStatusActive

Official records

From the FDA record

Device description
10fr 80cm feeding tube
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K100526 decided 22 Apr 2010 Active
  • FDA GUDID UDI-DI 10817522011820 listed 9 Aug 2016 Listed

Recalls

9 recalls · FDA

  • 7 recalls, same reason

    • Terminated Z-2518-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2515-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2520-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2519-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2517-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2514-2020 FDA Class II initiated 17 Jan 2020
    • Terminated Z-2516-2020 FDA Class II initiated 17 Jan 2020

    Feeding tube plastic tethered closure cap may possibly fracture or break. Possible health hazards: (1) Enteral feeding and medication administration could be possibly delayed, until replacement tube is placed into patient (2) Patient could be unnecessarily overexposed to radiation if multiple x-rays are needed to confirm placement of a new tube, if x-ray is used as the placement confirmation method.

  • 2 recalls, same reason

    • Terminated Z-3073-2017 FDA Class II initiated 23 Jun 2017
    • Terminated Z-3074-2017 FDA Class II initiated 23 Jun 2017

    Inadequate detectability of radiopaque stripes

Timeline

11 dated events

  1. Listed FDA GUDID 10817522011820
  2. Recall initiated FDA recalls Z-3073-2017
  3. Recall initiated FDA recalls Z-3074-2017
  4. Recall initiated FDA recalls Z-2518-2020
  5. Recall initiated FDA recalls Z-2515-2020
  6. Recall initiated FDA recalls Z-2520-2020
  7. Recall initiated FDA recalls Z-2519-2020
  8. Recall initiated FDA recalls Z-2517-2020
  9. Recall initiated FDA recalls Z-2514-2020
  10. Recall initiated FDA recalls Z-2516-2020

1 earlier event are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Ameritus
Generic name
Nasogastric/orogastric tube
Model / Ref / Catalog
AEG-100P-80
Primary DI / UDI-DI
10817522011820
510(k) Number
FDA product code
FPD
GMDN term
Nasogastric/orogastric tube
Device class
Class II
Regulation number
876.5980
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide

Similar devices

Other devices filed under FDA product code FPD (Tube, Feeding).

Other devices from Kentec Medical, Inc.

See all devices from Kentec Medical, Inc. →

Properties

  • Supplied sterile
  • Sterilise before use
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (8, all answered No)