Ameritus AEG-120P-110
by Kentec Medical, Inc. 2 variants
Ameritus AEG-120P-110 is a nasogastric/orogastric tube (FDA Class II; FDA product code FPD, Tube, Feeding) made by Kentec Medical, Inc., cleared under FDA 510(k) K100526 on 22 Apr 2010 and listed in FDA GUDID since 29 Jul 2016 (UDI-DI 10817522011042), active as of 23 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10817522011042 | Date29 Jul 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK100526 | Date22 Apr 2010 | StatusActive |
Official records
- AccessGUDID record 10817522011042
- FDA 510(k) database K100526
From the FDA record
- Device description
- 12fr 11cm feeding tube
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile; sterilise before use (Ethylene Oxide)
Across registries
- FDA 510(k) K100526 decided 22 Apr 2010 Active
- FDA GUDID UDI-DI 10817522011042 listed 29 Jul 2016 Listed
Recalls
-
- Terminated Z-2514-2020
- Terminated Z-2515-2020
- Terminated Z-2516-2020
- Terminated Z-2517-2020
- Terminated Z-2518-2020
- Terminated Z-2519-2020
- Terminated Z-2520-2020
Feeding tube plastic tethered closure cap may possibly fracture or break. Possible health hazards: (1) Enteral feeding and medication administration could be possibly delayed, until replacement tube is placed into patient (2) Patient could be unnecessarily overexposed to radiation if multiple x-rays are needed to confirm placement of a new tube, if x-ray is used as the placement confirmation method.
-
- Terminated Z-3073-2017
- Terminated Z-3074-2017
Inadequate detectability of radiopaque stripes
Timeline
- Listed FDA GUDID 10817522011042
- Recall initiated FDA recalls Z-3073-2017
- Recall initiated FDA recalls Z-3074-2017
- Recall initiated FDA recalls Z-2514-2020
- Recall initiated FDA recalls Z-2515-2020
- Recall initiated FDA recalls Z-2516-2020
- Recall initiated FDA recalls Z-2517-2020
- Recall initiated FDA recalls Z-2518-2020
- Recall initiated FDA recalls Z-2519-2020
- Recall initiated FDA recalls Z-2520-2020
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Ameritus
- Generic name
- Nasogastric/orogastric tube
- Model / Ref / Catalog
- AEG-120P-110
- Primary DI / UDI-DI
- 10817522011042
- 510(k) Number
- FDA product code
- FPD
- GMDN term
- Nasogastric/orogastric tube
- Device class
- Class II
- Regulation number
- 876.5980
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
- Size
- Catheter Gauge — 10 French
Similar devices
Other devices filed under FDA product code FPD (Tube, Feeding).
- NASOJEJUNAL FEEDING TUBE W/GASTRIC DRAINAGE by Sandoz Nutrition
- JEJUNO-CATH KIT by Health Improvement Assoc.
- TUBE, FEEDING, ARGYLE by Sherwood Medical Industries
- VYGON 157.252 000157252 by VYGON-Erzeugnisse für Medizin und Chirurgie-GmbH und Co. KG
- PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TRAY by North American Sterilization & Packaging Co.
- VYGON 157.152 000157152 by VYGON-Erzeugnisse für Medizin und Chirurgie-GmbH und Co. KG
- NUTRISAFE 2 by Vygon Corp.
- L.T.C. ENTERAL BAG ADMINISTRATION SET W/PUMP SET by Intl. Medical Marketing, Inc.
- WILSON-COOK PULL THROUGH PEG KIT by Wilson-Cook Medical, Inc.
- FEEDING TUBE Y-PORT CONNECTOR by Sandoz Nutrition