Apollo EZ

by Villa Sistemi Medicali S.p.A.

Part of a family of 34 devices: see the family page

Ref 9784NB0031

Apollo EZ (9784NB0031) is a device classified as Class IIb in the EU and Class II in the US made by Villa Sistemi Medicali S.P.A., registered in EUDAMED on 28 Jul 2025 (Basic UDI-DI 805773712FT2209C), cleared under FDA 510(k) K050190 on 25 Mar 2005 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 08057737120213), active as of 22 Oct 2026. 14 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

8 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K050190

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number805773712FT2209C Basic UDI-DI 08057737120213UDI-DIDate28 Jul 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number08057737120213 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) GUDID from GUDID NumberK050190 Date25 Mar 2005IssuedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 805773712FT2209C registered 28 Jul 2025 Active
  • FDA 510(k) K050190 decided 25 Mar 2005 Active
  • FDA GUDID UDI-DI 08057737120213 listed 24 Sep 2016 Listed

Recalls

15 recalls · 8 ongoing · FDA

  • 4 recalls, same reason

    • Ongoing Z-0763-2020 FDA Class II initiated 4 Nov 2019
    • Ongoing Z-0765-2020 FDA Class II initiated 4 Nov 2019
    • Ongoing Z-0764-2020 FDA Class II initiated 4 Nov 2019
    • Ongoing Z-0766-2020 FDA Class II initiated 4 Nov 2019

    An amendment to the IFU and Service Manual is being issued to prescribe the replacement of the angulation chain after 8 years of service of the of the unit. After testing, it was found that due to metal fatigue under sever workload conditions, the angulation chain might fail before the expected lifetime of 10 years.

  • 4 recalls, same reason

    • Ongoing Z-1063-2017 FDA Class II initiated 19 Feb 2016
    • Ongoing Z-1064-2017 FDA Class II initiated 19 Feb 2016
    • Ongoing Z-1065-2017 FDA Class II initiated 19 Feb 2016
    • Ongoing Z-1066-2017 FDA Class II initiated 19 Feb 2016

    The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame a physical barrier (the tabletop support arm. height ca. 60 em) to access a prohibited area not intended as a working position. 2) The directions for use (device labeling and instructions for use) did not contain an explicit exclusion of the prohibited area. 3.) The movement was activated inadvertently and continuously. and it was not released (the movement requires continuous activation). 4.) Delayed activation of the emergency stop.

  • 4 recalls, same reason

    • Terminated Z-1429-2017 FDA Class II initiated 27 Dec 2016
    • Terminated Z-1427-2017 FDA Class II initiated 27 Dec 2016
    • Terminated Z-1430-2017 FDA Class II initiated 27 Dec 2016
    • Terminated Z-1428-2017 FDA Class II initiated 27 Dec 2016

    Patient fell from the table because the footrest of the device detached from the table top while the patient was positioned on the table and table was moving from vertical position.

    • Terminated Z-1079-2015 FDA Class II initiated 14 Dec 2014

    The system does not provide the appropriate audible signal, permanent activation, and manual override, although the system is in high-level control functionality

    • Terminated Z-2160-2013 FDA Class II initiated 2 Aug 2013

    It has been discovered that the Air Kerma rate information is inconsistent in Continuous Fluoro modes 30x30 (12"x12") and 15x15 (6"x6). This could result in a deviation of the displayed values of Air Kerma Rate and Cumulated Air Kerma from the actual values greater then +/-35% and then in a failure to comply with the requirements of 21 CFR 1020.32(k)(6

    • Terminated Z-0702-2013 FDA Class II initiated 13 Dec 2012 on shared 510(k) K050190

    Values of fluoroscopy time, Air Kerma Rate and Cumulated Air Kerma may not be displayed "at the fluoroscopist's working position" as per 21 CFR 1003.21

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

18 dated events

  1. Listed FDA GUDID 08057737120213
  2. Recall initiated FDA recalls Z-1429-2017
  3. Recall initiated FDA recalls Z-1427-2017
  4. Recall initiated FDA recalls Z-1430-2017
  5. Recall initiated FDA recalls Z-1428-2017
  6. Recall initiated FDA recalls Z-0763-2020
  7. Recall initiated FDA recalls Z-0765-2020
  8. Recall initiated FDA recalls Z-0764-2020
  9. Recall initiated FDA recalls Z-0766-2020
  10. Registered EUDAMED 805773712FT2209C

8 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Apollo EZ EUDAMED
Villa Sistemi Medicali GUDID
Generic name
Stationary general-purpose fluoroscopic x-ray system, analogue
Device name
Apollo
Model / reference
9784NB0031 EUDAMED
Apollo EZ GUDID
Primary DI / UDI-DI
08057737120213
Basic UDI-DI
805773712FT2209C
Direct marketing DI
08057737120213
510(k) Number
FDA product code
KXJ, IXL, KPW
EMDN code
Z11030701 Conventional remote control tables
GMDN term
Stationary general-purpose fluoroscopic x-ray system, analogue
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1980, 892.1670, 892.1610
EU registration type
Standard device
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
9784NB0031
GUDID
Apollo EZ
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
IT-MF-000016860

Similar devices in this category

Other devices filed under REMOTE CONTROL TABLES.

Other devices from Villa Sistemi Medicali S.P.A.

See all devices from Villa Sistemi Medicali S.P.A. →

Properties

  • Prescription use
  • Serial number
Other properties (23, all answered No)