Skip to content

ARTIS pheno

by Siemens Healthcare GmbH

Ref 10849000Model MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno

ARTIS pheno (10849000) is a stationary angiographic x-ray system (EU MDR Class IIb; FDA Class II) made by Siemens Healthcare GmbH, registered in EUDAMED on 27 Apr 2026 (Basic UDI-DI 0405686900146UY), cleared under FDA 510(k) K254173 on 24 Apr 2026 (5 earlier submissions) and listed in FDA GUDID since 15 May 2017 (UDI-DI 04056869046877), active as of 25 Oct 2026. 32 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

22 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0405686900146UY Basic UDI-DI 04056869046877UDI-DIDate27 Apr 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK254173 Date24 Apr 2026DecidedStatusActive
United StatesGUDID listing GUDID Number04056869046877 UDI-DI Date15 May 2017ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686900146UY registered 27 Apr 2026 Active
  • FDA 510(k) K254173 decided 24 Apr 2026 Active· +5 more in the status table
  • FDA GUDID UDI-DI 04056869046877 listed 15 May 2017 Listed

Recalls

32 recalls · 22 ongoing · FDA

  • 3 recalls, same reason

    • Ongoing Z-2641-2026 FDA Class II initiated 20 May 2026
    • Ongoing Z-2642-2026 FDA Class II initiated 20 May 2026
    • Ongoing Z-2643-2026 FDA Class II initiated 20 May 2026

    Potential for loss of movement capability after adjusting the detector lift height to its maximum or minimum limits.

    • Ongoing Z-1814-2026 FDA Class II initiated 12 Mar 2026 UDI-DI 04056869046877 listed

    During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.

    • Ongoing Z-1653-2026 FDA Class II initiated 10 Mar 2026

    During patient examinations, the system may sporadically display a major increase of the x-ray dose applied to the patient. Despite the reported dose showing significantly higher, the actual applied x-ray dose levels are in accordance with the system settings and imaging conditions, as well as the applicable regulatory requirements.

  • 2 recalls, same reason

    • Ongoing Z-2205-2026 FDA Class II initiated 9 Mar 2026
    • Ongoing Z-2206-2026 FDA Class II initiated 9 Mar 2026

    During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

    • Ongoing Z-2529-2025 FDA Class II initiated 12 Aug 2025 UDI-DI 04056869046877 listed

    Limited system movements after startup .

  • 4 recalls, same reason

    • Ongoing Z-2019-2025 FDA Class II initiated 15 May 2025
    • Ongoing Z-2020-2025 FDA Class II initiated 15 May 2025
    • Ongoing Z-2021-2025 FDA Class II initiated 15 May 2025
    • Ongoing Z-2022-2025 FDA Class II initiated 15 May 2025

    In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

    • Ongoing Z-2361-2023 FDA Class II initiated 19 Jun 2023

    Due to a hardware issue in the cable connectors of the system generator, a thermal overload in the cable connections may occur when performing excessive fluoroscopy/acquisitions, a burning smell may be detectable coming from the generator cabinet and the system may lose the imaging functionality of the corresponding plane and result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system

    • Ongoing Z-1498-2023 FDA Class II initiated 2 Feb 2023 UDI-DI 04056869046877 listed

    If, during the procedure, X-ray has been released and a reference image has been stored, the following issue may occur: If "Adjust C-arm to Ref" is activated when the C-Arm is positioned outside of the working range the C-Arm will reach the target position with an inaccuracy of 5-10 mm. As a result, the message Endposition reached will be displayed .Leading to unintended direction of the movement causing crushing of a patient, staff member, operator, or equipmen Live images may not match the previously stored reference images. Overlay images may be shown inaccurate on anatomy (e.g., DSA Roadmap workflow does not match real anatomy). This may cause e.g., a vessel perforation in DSA roadmap.

    • Ongoing Z-1311-2023 FDA Class II initiated 2 Feb 2023

    In the event of any unintended table movement, the system may not detect the incorrect direction, could lead to the injury of a patient, staff member, operator, or equipment.

    • Ongoing Z-0956-2023 FDA Class II initiated 16 Dec 2022

    Mechanical connection between the tabletop and table base may be lost.

    • Ongoing Z-0119-2023 FDA Class II initiated 20 Sep 2022 UDI-DI 04056869046877 listed

    Siemens has become aware of three potential software issues with ARTIS pheno systems with software version VE10B. This may lead to a hazardous situation for patients if treatment cannot be continued on the system and treatment needs to be continued on an alternate system.

    • Ongoing Z-1646-2022 FDA Class II initiated 10 Aug 2022 UDI-DI 04056869046877 listed

    Siemens has become aware of a potential hardware issue with Artis Q, Artis Q.zen, Artis pheno and Artis icono systems with a specific lot of X-ray tubes. In rare cases, if the error detection mechanism fails, it will not be possible to release X-ray any longer until system shutdown.

    • Ongoing Z-1294-2022 FDA Class II initiated 10 Jun 2022 UDI-DI 04056869046877 listed

    A video signal from one of the transceivers of the Large Display may be lost. In very rare cases, both transceivers of the Large Display could potentially fail which can lead to the loss of both video signals. This issue can sporadically affect the Large Display in the examination room as well as the displays in the control room.

    • Ongoing Z-0987-2022 FDA Class II initiated 25 Feb 2022 UDI-DI 04056869046877 listed

    Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed

    • Ongoing Z-1339-2022 FDA Class II initiated 25 Feb 2022 UDI-DI 04056869046877 listed

    After CT image data from Toshiba is loaded, image mirroring can occur along the horizontal and vertical image axes. If this error occurs, the patient orientation/position may be misinterpreted and result in inappropriate treatment, even if the incorrect visualization is obvious.

    • Ongoing Z-2029-2021 FDA Class II initiated 27 May 2021

    Software error VE10B -In case of a fault within the drivetrain of an axis and while performing a stepped peripheral imaging (PERISTEPPING/PERIVISION), the C-arm may leave its intended travel path by up to 22 cm (9") result in canceling clinical treatment or to continue treatment on an alternative system

    • Terminated Z-0515-2022 FDA Class II initiated 12 Oct 2021 UDI-DI 04056869046877 listed

    Four potential software issues with Artis pheno and Artis icono systems with software VE20C: 1. Updated calibration data not saved with measurement after scene+/-; 2. No x-ray possible, system shutdown/restart might be required during intervention; 3. Corrupted Image during Roadmap; 4. Unintended shutdown of Imaging System with UPS (Uninterruptable Power Supply) option

    • Terminated Z-1497-2021 FDA Class II initiated 19 Mar 2021

    Siemens has become aware of a potential issue with software version VE20C. Planned procedures may have to be terminated and performed on an alternative x-ray system.

    • Terminated Z-2108-2020 FDA Class II initiated 22 Apr 2020

    If the C-arm leaves its intended travel path due to a fault within the drivetrain, movements may be impacted or impossible and the area of interest cannot be reached. In the event the C-arms movements are not possible, the system can only be returned to normal operation with the support of a field service engineer

    • Terminated Z-1340-2020 FDA Class II initiated 24 Jan 2020

    Potential exists for one or more axes of the robotic stand to become blocked by their safety brakes; In the event the axis is blocked by its safety brake, the robotic stand can no longer perform the intended movements

    • Terminated Z-0807-2020 FDA Class II initiated 20 Dec 2019

    The potential exists for system movement to be permanently blocked by an activation of the collision sensor integrated in the cover of the collimator even when no collision has occurred.

    • Terminated Z-1905-2019 FDA Class II initiated 6 Jun 2019

    Artis Zee, Artis Q, Artis Pheno or Artis Icono systems equipped with a DCS Extended or DCS Movable, the potential exists for individual screws of the screwed connection joining the pivot bearing to the ceiling-mounted support to work loose or snap off, can result in severe injuries to patients and operating personnel

    • Terminated Z-3190-2018 FDA Class II initiated 29 Jul 2018

    Temperature of the detector may fall out of its designed working range (cool down) due to incorrectly configured temperature control unit. This unintentional system behavior may occur while the unit is powered down for long periods (e.g. at night).

    • Terminated Z-2748-2018 FDA Class II initiated 22 Jun 2018

    Potential hardware issue which may cause thermal effects and possible damage to system parts.

    • Terminated Z-2524-2018 FDA Class II initiated 30 May 2018

    During manual LAO/RAO rotation at maximum speed or a combination of LAO/RAO and Cran/Caud rotation at maximum speed, the possibility exists for the safety monitoring within the system control to become activated. As a result, the C-arm stops the rotation and can drop up to 40 mm (1.6 ).

    • Terminated Z-2283-2018 FDA Class II initiated 1 May 2018

    If the C-arm is manually moved in the longitudinal direction to a fully extended position, the system's safety stop mechanism may be activated. As a result, the C-arm stops the movement and can drop up to 20 mm (0.8 ). Under certain circumstances, the cover of the detector or collimator can touch and possibly injure the patient due to the C-arm drop. This could lead to a situation in which it is necessary to stop the clinical treatment or continue the treatment on an alternative system.

Timeline

40 dated events

  1. Recall initiated FDA recalls Z-2529-2025
  2. Recall initiated FDA recalls Z-2205-2026
  3. Recall initiated FDA recalls Z-2206-2026
  4. Recall initiated FDA recalls Z-1653-2026
  5. Recall initiated FDA recalls Z-1814-2026
  6. Cleared FDA 510(k) K254173
  7. Registered EUDAMED 0405686900146UY
  8. Recall initiated FDA recalls Z-2641-2026
  9. Recall initiated FDA recalls Z-2642-2026
  10. Recall initiated FDA recalls Z-2643-2026

30 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Stationary angiographic x-ray system, digital
Device name
MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno
Model / reference
MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno, 10849000
Primary DI / UDI-DI
04056869046877
Basic UDI-DI
0405686900146UY
FDA product code
OWB, JAA, JAK, IZI
EMDN code
Z11030102 Stationary angiography systems for angiographic and cardiologic studies
GMDN term
Stationary angiographic x-ray system, digital
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1650, 892.1750, 892.1600
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000006122

Similar devices in this category

Other devices filed under STATIONARY ANGIOGRAPHY SYSTEMS FOR ANGIOGRAPHIC AND CARDIOLOGIC STUDIES.

Other devices from Siemens Healthcare GmbH

See all devices from Siemens Healthcare GmbH →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)