ARTIS pheno
Ref 10849000Model MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno
ARTIS pheno (10849000) is a stationary angiographic x-ray system (EU MDR Class IIb; FDA Class II) made by Siemens Healthcare GmbH, registered in EUDAMED on 27 Apr 2026 (Basic UDI-DI 0405686900146UY), cleared under FDA 510(k) K254173 on 24 Apr 2026 (5 earlier submissions) and listed in FDA GUDID since 15 May 2017 (UDI-DI 04056869046877), active as of 25 Oct 2026. 32 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
22 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686900146UY 04056869046877 | Date27 Apr 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK254173 | Date24 Apr 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04056869046877 | Date15 May 2017 | StatusListed |
Official records
- EUDAMED public site 0405686900146UY
- AccessGUDID record 04056869046877
- FDA 510(k) database K254173
- FDA 510(k) database K241572
- FDA 510(k) database K230949
- FDA 510(k) database K220409
- FDA 510(k) database K201156
- FDA 510(k) database K163286
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686900146UY registered 27 Apr 2026 Active
- FDA 510(k) K254173 decided 24 Apr 2026 Active
- FDA GUDID UDI-DI 04056869046877 listed 15 May 2017 Listed
Recalls
-
- Ongoing Z-2641-2026
- Ongoing Z-2642-2026
- Ongoing Z-2643-2026
Potential for loss of movement capability after adjusting the detector lift height to its maximum or minimum limits.
-
- Ongoing Z-1814-2026
During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.
-
- Ongoing Z-1653-2026
During patient examinations, the system may sporadically display a major increase of the x-ray dose applied to the patient. Despite the reported dose showing significantly higher, the actual applied x-ray dose levels are in accordance with the system settings and imaging conditions, as well as the applicable regulatory requirements.
-
- Ongoing Z-2205-2026
- Ongoing Z-2206-2026
During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.
-
- Ongoing Z-2529-2025
Limited system movements after startup .
-
- Ongoing Z-2019-2025
- Ongoing Z-2020-2025
- Ongoing Z-2021-2025
- Ongoing Z-2022-2025
In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.
-
- Ongoing Z-2361-2023
Due to a hardware issue in the cable connectors of the system generator, a thermal overload in the cable connections may occur when performing excessive fluoroscopy/acquisitions, a burning smell may be detectable coming from the generator cabinet and the system may lose the imaging functionality of the corresponding plane and result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system
-
- Ongoing Z-1498-2023
If, during the procedure, X-ray has been released and a reference image has been stored, the following issue may occur: If "Adjust C-arm to Ref" is activated when the C-Arm is positioned outside of the working range the C-Arm will reach the target position with an inaccuracy of 5-10 mm. As a result, the message Endposition reached will be displayed .Leading to unintended direction of the movement causing crushing of a patient, staff member, operator, or equipmen Live images may not match the previously stored reference images. Overlay images may be shown inaccurate on anatomy (e.g., DSA Roadmap workflow does not match real anatomy). This may cause e.g., a vessel perforation in DSA roadmap.
-
- Ongoing Z-1311-2023
In the event of any unintended table movement, the system may not detect the incorrect direction, could lead to the injury of a patient, staff member, operator, or equipment.
-
- Ongoing Z-0956-2023
Mechanical connection between the tabletop and table base may be lost.
-
- Ongoing Z-0119-2023
Siemens has become aware of three potential software issues with ARTIS pheno systems with software version VE10B. This may lead to a hazardous situation for patients if treatment cannot be continued on the system and treatment needs to be continued on an alternate system.
-
- Ongoing Z-1646-2022
Siemens has become aware of a potential hardware issue with Artis Q, Artis Q.zen, Artis pheno and Artis icono systems with a specific lot of X-ray tubes. In rare cases, if the error detection mechanism fails, it will not be possible to release X-ray any longer until system shutdown.
-
- Ongoing Z-1294-2022
A video signal from one of the transceivers of the Large Display may be lost. In very rare cases, both transceivers of the Large Display could potentially fail which can lead to the loss of both video signals. This issue can sporadically affect the Large Display in the examination room as well as the displays in the control room.
-
- Ongoing Z-0987-2022
Five potential software issues affecting Artis pheno and Artis icono systems in combination with a Siemens Healthineers table or Trumpf/MAQUET table (OEM). The potential software errors are related to the block movements function and manual rotation of the flat detector. Depending on the status of the intervention, the limited functionality may not be sufficient to continue with treatment as planned. This may result in a situation where clinical treatment may be delayed until an additional restart is performed
-
- Ongoing Z-1339-2022
After CT image data from Toshiba is loaded, image mirroring can occur along the horizontal and vertical image axes. If this error occurs, the patient orientation/position may be misinterpreted and result in inappropriate treatment, even if the incorrect visualization is obvious.
-
- Ongoing Z-2029-2021
Software error VE10B -In case of a fault within the drivetrain of an axis and while performing a stepped peripheral imaging (PERISTEPPING/PERIVISION), the C-arm may leave its intended travel path by up to 22 cm (9") result in canceling clinical treatment or to continue treatment on an alternative system
-
- Terminated Z-0515-2022
Four potential software issues with Artis pheno and Artis icono systems with software VE20C: 1. Updated calibration data not saved with measurement after scene+/-; 2. No x-ray possible, system shutdown/restart might be required during intervention; 3. Corrupted Image during Roadmap; 4. Unintended shutdown of Imaging System with UPS (Uninterruptable Power Supply) option
-
- Terminated Z-1497-2021
Siemens has become aware of a potential issue with software version VE20C. Planned procedures may have to be terminated and performed on an alternative x-ray system.
-
- Terminated Z-2108-2020
If the C-arm leaves its intended travel path due to a fault within the drivetrain, movements may be impacted or impossible and the area of interest cannot be reached. In the event the C-arms movements are not possible, the system can only be returned to normal operation with the support of a field service engineer
-
- Terminated Z-1340-2020
Potential exists for one or more axes of the robotic stand to become blocked by their safety brakes; In the event the axis is blocked by its safety brake, the robotic stand can no longer perform the intended movements
-
- Terminated Z-0807-2020
The potential exists for system movement to be permanently blocked by an activation of the collision sensor integrated in the cover of the collimator even when no collision has occurred.
-
- Terminated Z-1905-2019
Artis Zee, Artis Q, Artis Pheno or Artis Icono systems equipped with a DCS Extended or DCS Movable, the potential exists for individual screws of the screwed connection joining the pivot bearing to the ceiling-mounted support to work loose or snap off, can result in severe injuries to patients and operating personnel
-
- Terminated Z-3190-2018
Temperature of the detector may fall out of its designed working range (cool down) due to incorrectly configured temperature control unit. This unintentional system behavior may occur while the unit is powered down for long periods (e.g. at night).
-
- Terminated Z-2748-2018
Potential hardware issue which may cause thermal effects and possible damage to system parts.
-
- Terminated Z-2524-2018
During manual LAO/RAO rotation at maximum speed or a combination of LAO/RAO and Cran/Caud rotation at maximum speed, the possibility exists for the safety monitoring within the system control to become activated. As a result, the C-arm stops the rotation and can drop up to 40 mm (1.6 ).
-
- Terminated Z-2283-2018
If the C-arm is manually moved in the longitudinal direction to a fully extended position, the system's safety stop mechanism may be activated. As a result, the C-arm stops the movement and can drop up to 20 mm (0.8 ). Under certain circumstances, the cover of the detector or collimator can touch and possibly injure the patient due to the C-arm drop. This could lead to a situation in which it is necessary to stop the clinical treatment or continue the treatment on an alternative system.
Timeline
- Recall initiated FDA recalls Z-2529-2025
- Recall initiated FDA recalls Z-2205-2026
- Recall initiated FDA recalls Z-2206-2026
- Recall initiated FDA recalls Z-1653-2026
- Recall initiated FDA recalls Z-1814-2026
- Cleared FDA 510(k) K254173
- Registered EUDAMED 0405686900146UY
- Recall initiated FDA recalls Z-2641-2026
- Recall initiated FDA recalls Z-2642-2026
- Recall initiated FDA recalls Z-2643-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Stationary angiographic x-ray system, digital
- Device name
- MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno
- Model / reference
- MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno, 10849000
- Primary DI / UDI-DI
- 04056869046877
- Basic UDI-DI
- 0405686900146UY
- FDA product code
- OWB, JAA, JAK, IZI
- EMDN code
- Z11030102 Stationary angiography systems for angiographic and cardiologic studies
- GMDN term
- Stationary angiographic x-ray system, digital
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.1650, 892.1750, 892.1600
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- DE-MF-000006122
Similar devices in this category
Other devices filed under STATIONARY ANGIOGRAPHY SYSTEMS FOR ANGIOGRAPHIC AND CARDIOLOGIC STUDIES.
- Trinias 563-79864-77 by SHIMADZU CORPORATION
- Trinias 563-79863-07 by SHIMADZU CORPORATION
- Azurion 7 M20 722079 by Philips Medical Systems Nederland B.V.
- Azurion 3 M15 722064 by Philips Medical Systems Nederland B.V.
- INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000F by CANON INC.
- Artis one 10848600 by Siemens Shenzhen Magnetic Resonance Ltd.
- Allia IGS 3, Allia IGS 5, Allia IGS 7, Allia IGS 7 OR by GE Medical Systems SCS
- 88000993 by Shanghai United Imaging Healthcare Co., Ltd.
- IGS WF SP 5796561 by GE Medical Systems SCS
- INTERVENTIONAL ANGIOGRAPHY SYSTEM INFX-8000V by CANON INC.