Skip to content

Barco MNA-240

by Barco, Inc. EUDAMEDGUDID

Active European Union and United States

Ref 600301482Model Nexxis OR, Nexxis 2.xx

Regulatory status

as of 27 Oct 2026

Recall ongoing. 2 ongoing FDA recalls. See recalls

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number05415334053663 UDI-DIDate4 Jun 2025ListedStatusIn distribution
European UnionCE/MDR EUDAMED Number5415334_NexxisOR_P4 Basic UDI-DIDate17 Oct 2024RegisteredStatusActive

Coverage

2 jurisdictions

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaSwedenFinlandFinlandSwedenFinlandFinlandSwedenSwedenLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyGermanyPolandPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaPolandFranceFranceAustriaHungaryRomaniaFranceFranceSloveniaBulgariaPortugalSpainSpainItalySpainSpainCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Certificates

0 certificates · EUDAMED

No notified-body certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

3 recalls · 2 ongoing · FDA

    • Ongoing Z-1994-2025 FDA Class II initiated 9 May 2025

    Cathode ray tube display system encoders and decoders have same MAC address; new system setup with two or more affected units can lead to systems not functioning reliably:audio, video and/or control signals might be interrupted or fall away, displays might switch to failover and back multiple times, devices/sources/sinks might not be discovered/available, might lead to delayed/prolonged procedures

    • Ongoing Z-1854-2022 FDA Class II initiated 27 Jul 2022

    installation issues

    • Completed Z-2332-2024 FDA Class II initiated 24 Apr 2024

    We have identified a potential issue with the SFP+ module supplied by Molex (Part Number: B620050) when connected to the ETH0 slot of either the MNA-6x0 ENC HDMI or MNA-4x0 ENC HDMI. In some instances, this connection may render the first HDMI channel inaccessible, making both the channel and the respective MNA ENC unit unusable. Additionally, readings from the module become unavailable when this issue arises. Similarly, when this Molex module is connected to the ETH0 slot of an MNA-620 ENC ANA, readings may also become inaccessible.

Specification

EUDAMED · GUDID

Trade Name
Barco
Generic Name
Operating room audiovisual data/device management system
Device Name
MNA-120, MNA-240, MNA-420, MNA-440, NMS 1.18, NMS 2.xx, MNA-420 ENC ANA, MCC-300, MNA-410 WPM
Model / Ref / Catalog
Nexxis OR, Nexxis 2.xx, 600301482, MNA-240
Primary DI / UDI-DI
05415334053663
Basic UDI-DI
5415334_NexxisOR_P4
510(k) Number
FDA Product Code
DXJ
EMDN Code
Z11069099 Various digital bioimaging management instruments - other
GMDN Term
Operating room audiovisual data/device management system
Device Class
Class I EUDAMED
Class II GUDID
Regulation Number
870.2450
Market of Registration
Belgium
Commercial Distribution
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
Nexxis OR, Nexxis 2.xx
600301482
GUDID
MNA-240
Device ClassEUDAMED
Class I
GUDID
Class II

Other devices from Barco, Inc.

See all devices from Barco, Inc. →

Properties

  • Prescription Use
  • Serial Number
  • Manufacturing Date

Other properties (21)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • CMR Substance: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Endocrine Disruptor: No
  • Administering Medicine: No
  • Measuring Function: No
  • Incorporates Medicinal Product: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No