Identity
- Trade Name
- Basic Chlorine Sentinel FDA UDI
- Generic Name
- Haemodialysis system chlorine monitor FDA UDI
- Device Name
- The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop. The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area. A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller. A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved. FDA UDI
- Model / Reference
- NSS-BCS-001 FDA UDI
- Description
- The Nelson Sentinel Series Basic Chlorine Sentinel is a complete system that attaches to the drain of a hemodialysis water treatment system sample port. The Basic Chlorine Sentinel detects dissolved chlorine by an auxiliary meter detection technology, self-monitors for maintenance-required conditions, loss of electrical power, as well as two other system conditions such as flooding and the status of RO shutdown alarm. The device chlorine monitoring probe is preferably placed after the second carbon filter, before the RO machine or at the beginning of the patient water treatment loop. The device has three components – a lockable master control enclosure, a lockable probe/tester enclosure, and the remote module installed in the patient area. A chlorine concentration equal to or above the set-point (default: 0.10mg/L) will activate the buzzers and the red CHLORINE alarm indicators for as long as the condition exists. The buzzers can only be muted for 3 minutes (then automatically reset) for as long as the condition exists. The yellow AUTO-TEST OK/CL DETECTED indication will latch. The AUTO-TEST/CL DETECTED indication can be deactivated after the event by pressing the blue RESET PUSHBUTTON on the front cover of the controller. A probe failure or the activation of one of the auxiliary input relays will activate the yellow MAINTENANCE needed indicators as well as the Buzzers which will remain activated as long as the condition exists. However, the buzzers can be muted by the key mute switch while the maintenance issue is being resolved. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 00860006352103 FDA UDI
- FDA Product Code
- PSX FDA UDIMSY FDA UDIFIP FDA UDI
- GMDN Term
- Haemodialysis system chlorine monitor FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 876.5665 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Haemodialysis system chlorine monitor
Basic Chlorine Sentinel by Nelson Environmental Technologies Inc — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Haemodialysis system chlorine monitor.
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
- BMT Medizintechnik GmbH — BMT Medizintechnik GmbH · Class I
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Nelson Environmental Technologies Inc
Sources (1)
- FDA UDI 13131fdc-e803-44d2-acab-35465555da12 33 fields · synced Jun 8, 2026