BD PrepStain Slide Processor 490100
by Becton, Dickinson and Company
BD PrepStain Slide Processor 490100 is a microscope slide maker/stainer IVD (FDA Class III; FDA product code MKQ, Processor, Cervical Cytology Slide, Automated) made by Becton, Dickinson and Company, approved under FDA PMA P970018 on 17 Jun 1999 and listed in FDA GUDID since 22 Jul 2015 (UDI-DI 00382904901004), active as of 26 Oct 2026. 11 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00382904901004 | Date22 Jul 2015 | StatusListed |
| United States | FDA PMAAPPR | NumberP970018 | Date17 Jun 1999 | StatusActive |
Official records
- AccessGUDID record 00382904901004
- FDA PMA database P970018
From the FDA record
- Device description
- BD PrepStain® Slide Processor transfers cell samples from the specimen tubes to settling chambers mounted to microscope slides. The instrument then automatically stains and rinses each slide
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA PMA P970018 decided 17 Jun 1999 Active
- FDA GUDID UDI-DI 00382904901004 listed 22 Jul 2015 Listed
Recalls
-
- Terminated Z-0877-2017
BD has confirmed that a portion of BD SurePath" collection vials associated with specific production lots may contain caps that are cracked which can lead to leaking of the preservative fluid.
-
- Terminated Z-1815-2012
- Terminated Z-1813-2012
- Terminated Z-1811-2012
- Terminated Z-1814-2012
- Terminated Z-1812-2012
The PrepStain Syringing Pipettes may not dispense the minimum volume of 7.5 mL of the sample due to leaking. This event resulted in an increase in complaints of leaking syringing pipettes
-
- Terminated Z-2085-2012
- Terminated Z-2087-2012
- Terminated Z-2088-2012
- Terminated Z-2086-2012
Some Prep Stain Kit, 1.2 DiTi Cones have been found to be leaking and the PrepStain Preparation kits contain incorrect preventive maintenance (PM) instructions.
-
- Terminated Z-1090-2009
Software Error in the non-gyn program of some devices may cause non-gyn samples to be incorrectly transferred from centrifuge tubes to slides potentially result in mismatched patient results.
Timeline
- Recall initiated FDA recalls Z-2087-2012
- Recall initiated FDA recalls Z-2088-2012
- Recall initiated FDA recalls Z-2086-2012
- Recall initiated FDA recalls Z-1815-2012
- Recall initiated FDA recalls Z-1813-2012
- Recall initiated FDA recalls Z-1811-2012
- Recall initiated FDA recalls Z-1814-2012
- Recall initiated FDA recalls Z-1812-2012
- Listed FDA GUDID 00382904901004
- Recall initiated FDA recalls Z-0877-2017
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- BD PrepStain Slide Processor
- Generic name
- Microscope slide maker/stainer IVD
- Model / Ref / Catalog
- 490100
- Primary DI / UDI-DI
- 00382904901004
- PMA number
- FDA product code
- MKQ
- GMDN term
- Microscope slide maker/stainer IVD
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution
- Size
- Depth — 25 InchWidth — 40 InchHeight — 34 Inch