BiCOAG CD-B610LA
Ref CD-B610LA
BiCOAG CD-B610LA is an endoscopic electrosurgical electrode (EU MDD Class IIb; FDA Class II; FDA product code KNS, Unit, electrosurgical, endoscopic (with or without accessories)) made by Gyrus Acmi, Inc., registered in EUDAMED on 2 Sep 2026 (Basic UDI-DI B-00821925039469), cleared under FDA 510(k) K123319 on 14 Dec 2012 and listed in FDA GUDID since 13 Oct 2016 (UDI-DI 00821925039469), active as of 23 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00821925039469 00821925039469 | Date2 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00821925039469 | Date13 Oct 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK123319 | Date14 Dec 2012 | StatusActive |
Official records
- EUDAMED public site B-00821925039469
- AccessGUDID record 00821925039469
- FDA 510(k) database K123319
From the FDA record
- Device description
- 10FR COAX HEMOSTATIC PROBE CD-B610LA BICOAG BIPOLAR HEMO PROB 3.3MM, 350 CM
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-00821925039469 registered 2 Sep 2026 Active
- FDA 510(k) K123319 decided 14 Dec 2012 Active
- FDA GUDID UDI-DI 00821925039469 listed 13 Oct 2016 Listed
Recalls
-
- Ongoing Z-3246-2026
- Ongoing Z-3244-2026
- Ongoing Z-3247-2026
- Ongoing Z-3245-2026
Potential for detachment of ceramic tip due to manufacturing without the designated amount of adhesive.
-
- Ongoing Z-1481-2024
The BICOAG Hemostasis Probe with a coaxial plug was mispackaged into the package and labeled as a BICOAG Hemostasis Probe with a fixed pin connector.
Timeline
- Cleared FDA 510(k) K123319
- Listed FDA GUDID 00821925039469
- Recall initiated FDA recalls Z-1481-2024
- Recall initiated FDA recalls Z-3246-2026
- Recall initiated FDA recalls Z-3244-2026
- Recall initiated FDA recalls Z-3247-2026
- Recall initiated FDA recalls Z-3245-2026
- Registered EUDAMED B-00821925039469
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- BiCOAG
- Generic name
- Endoscopic electrosurgical electrode, bipolar, single-use
- Model / reference
- CD-B610LA
- Primary DI / UDI-DI
- 00821925039469
- Basic UDI-DI
- B-00821925039469
- 510(k) Number
- FDA product code
- KNS
- EMDN code
- K0201011202 Laparoscopic and thoracoscopic electrosurgery probes, single-use
- GMDN term
- Endoscopic electrosurgical electrode, bipolar, single-use
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 876.4300
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under MONO- AND BIPOLAR SURGICAL INSTRUMENTS, SINGLE-USE.
- Multifunctional Operational Dissectors(Electrosurgical pencils) SY-IIIA(N)-0 by Zhejiang Shuyou Surgical Instrument Co., Ltd
- LigaSure LF1212A by Covidien LP
- Multifunctional Operational Dissectors(Electrosurgical pencils) SY-IIA(N)-1 by Zhejiang Shuyou Surgical Instrument Co., Ltd
- ENSEAL NSLX125S by Ethicon Endo-Surgery, LLC
- ENSEAL NSLG2C35A by Ethicon Endo-Surgery, LLC
- Wolf™ Lumitip™ Dissector MID1/A000195-4 by ATRICURE, INC.
- ClearHemograsper FM-HG0001(2000) by Finemedix Co., Ltd.
- Endoscopic Instruments-Dissector DI-5770-45C by Lagis Enterprise Co., Ltd.
- Fischer Cone 900-156 by CooperSurgical, Inc.
- Logi Curved Dissector 240mm 120-7901 by Surgical Innovations Ltd.