C253A
Ref 04573596214510
C253A (04573596214510) is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II) made by Fujifilm Corporation, registered in EUDAMED on 13 Feb 2026 (Basic UDI-DI 457359621C253A46), cleared under FDA 510(k) K220295 on 29 Apr 2022 (3 earlier submissions) and listed in FDA GUDID since 22 Jan 2024 (UDI-DI 04573596214510), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number457359621C253A46 04573596214510 | Date13 Feb 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04573596214510 | Date22 Jan 2024 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK220295 | Date29 Apr 2022 | StatusActive |
Official records
- EUDAMED public site 457359621C253A46
- AccessGUDID record 04573596214510
- FDA 510(k) database K220295
- FDA 510(k) database K202422
- FDA 510(k) database K191233
- FDA 510(k) database K181376
From the FDA record
- Device description
- Probe
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 457359621C253A46 registered 13 Feb 2026 Active
- FDA 510(k) K220295 decided 29 Apr 2022 Active
- FDA GUDID UDI-DI 04573596214510 listed 22 Jan 2024 Listed
Recalls
-
- Ongoing Z-0189-2022
Diagnostic ultrasound system with the specified software version and used in conjunction with a Fujifilm (formally Hitachi) transducer does not display the measurement results correctly with two cardiology measurement functions: Mitral Regurgitation Flow (MR Flow) Measurement; Mitral Valve (MV) Measurement. In addition there is an error in the instruction manual.
-
- Ongoing Z-0192-2022
When the ultrasound system is used in combination with a Fujifilm (formally Hitachi) transducer, there is an error in the calculation formula of Effective Regurgitant Orifice Area (EROA) when you perform MR Flow combined with Left Ventricular Outflow Tract Flow (LVOT Flow) after performing an echocardiogram. The incorrect value is displayed. In addition, the error appears in the instruction manual
Timeline
- Cleared FDA 510(k) K181376
- Cleared FDA 510(k) K191233
- Cleared FDA 510(k) K202422
- Recall initiated FDA recalls Z-0189-2022
- Recall initiated FDA recalls Z-0192-2022
- Cleared FDA 510(k) K220295
- Listed FDA GUDID 04573596214510
- Registered EUDAMED 457359621C253A46
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Model / reference
- 04573596214510 EUDAMEDC253A GUDID
- Primary DI / UDI-DI
- 04573596214510
- Basic UDI-DI
- 457359621C253A46
- Direct marketing DI
- 04573596214510
- FDA product code
- ITX, IYO, IYN
- EMDN code
- Z110402010201 Curvilinear transcutaneous two–dimensional ultrasound probes (convex–array)
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570, 892.1560, 892.1550
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 04573596214510 | C253A |
| Device class | Class IIa | Class II |
| Sterilise before use | Yes | No |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 04573596214510: EUDAMED states Yes, FDA GUDID states No.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Manufacturer details
- EUDAMED SRN
- JP-MF-000010401
- Authorised representative
- FUJIFILM Healthcare Europe GmbH DE-AR-000040920
Similar devices in this category
Other devices filed under CURVILINEAR TRANSCUTANEOUS TWO–DIMENSIONAL ULTRASOUND PROBES (CONVEX–ARRAY).
- C1-6VN-D by GE HEALTHCARE JAPAN CORPORATION
- Vscan Air CL GP000160 by Ge Vingmed Ultrasound
- 9C2 Transducer 11503103 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- C60xf/5-2 MHz P18024-21 by Fujifilm Sonosite, Inc.
- CA621 9600155000 by Esaote S.p.A.
- C60xf/5-2 MHz P18024-21A by Fujifilm Sonosite, Inc.
- 8C-RS H40402LS by GE Healthcare Japan Corporation
- 9C2 Transducer 9002 by BK MEDICAL APS
- GP-C01 99-7903-00 by Interson Corporation
- 11M2 Transducer 11653755 by SIEMENS MEDICAL SOLUTIONS USA, INC.