Skip to content

Carescape R860

by Datex-Ohmeda Inc. 2 variants

510(k) K142679

Carescape R860 is a medical device (FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Datex-Ohmeda Inc., cleared under FDA 510(k) K142679 on 12 Jun 2015, active as of 22 Oct 2026. 6 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK142679 Date12 Jun 2015ClearedStatusActive

Official records

From the FDA record

Received by the FDA
19 Sep 2014
FDA decision
12 Jun 2015 (Substantially Equivalent)
FDA review time
266 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K142679 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

6 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1227-2022 FDA Class I initiated 18 Apr 2022
    • Ongoing Z-1226-2022 FDA Class I initiated 18 Apr 2022

    Insufficient battery backup power resulting in premature shutdown of the ventilator when not connected to AC mains power supply.

    • Terminated Z-2883-2020 FDA Class II initiated 14 Jul 2020

    The oxygen sensor for certain CARESCAPE R860 devices has a potential issue that may result in an inaccurate display of FiO2 value from what is being delivered.

    • Terminated Z-0463-2019 FDA Class I initiated 5 Oct 2018

    The ventilator Inspiratory Safety Guard (ISG) may disconnect from the breathing circuit pathway. As a result, this could create a loss of ventilation which may lead to inadequate oxygenation for patients, increasing the possibility of hypoxia.

    • Terminated Z-2738-2018 FDA Class II initiated 28 Jun 2018

    The Neonatal Flow Sensor Cable may be missing the connector housing exposing the wires in the cable.

    • Terminated Z-2266-2018 FDA Class II initiated 8 Dec 2017

    Potential for the display processor to experience an unexpected failure.

Timeline

7 dated events

  1. Cleared FDA 510(k) K142679
  2. Recall initiated FDA recalls Z-2266-2018
  3. Recall initiated FDA recalls Z-2738-2018
  4. Recall initiated FDA recalls Z-0463-2019
  5. Recall initiated FDA recalls Z-2883-2020
  6. Recall initiated FDA recalls Z-1227-2022
  7. Recall initiated FDA recalls Z-1226-2022

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CBK
FDA applicant
Datex-Ohmeda, Inc.
Device class
Class II
Regulation
21 CFR Part 868.5895
Advisory committee
Anesthesiology
FDA decision
SESE Substantially Equivalent

Devices cleared under K142679

1 device · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K142679
UDI-DISize and differences
CARESCAPE R860
Datex-Ohmeda Inc.
R86000840682102346 —On the market

Similar devices

Other devices filed under FDA product code CBK (Ventilator, Continuous, Facility Use).

Other devices from Datex-Ohmeda Inc.

See all devices from Datex-Ohmeda Inc. →