ACS:180 Troponin I Assay (CTNI)
510(k) K980528
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK980528 | Date3 Mar 1998 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Chiron Diagnostics ACS:180 Troponin I Assay (Ctni)
- 510(k) Number
- FDA Product Code
- MMI
- Device Class
- Class II
- Regulation
- 21 CFR Part 862.1215
- Advisory Committee
- Clinical Chemistry
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The ACS:180 Troponin I Assay (CTNI) is an immunoassay method for quantifying cardiac troponin I, a biomarker used to detect myocardial infarction. It falls under the category of immunoassay devices designed to measure troponin subunits in clinical chemistry applications. This assay is intended for use with automated chemiluminescence systems to provide precise and sensitive detection of troponin I levels in patient samples.
This device is supplied as a reagent kit for use on the ACS:180 Automated Chemiluminescence System and is intended for in vitro diagnostic use in clinical laboratories. It is designed to measure troponin I in serum or heparinized plasma samples, aiding in the diagnosis of acute coronary syndromes. The assay holds an FDA 510(k) clearance under the traditional pathway, classified as a Class II device under regulation number 862.1215, and is regulated within the medical specialty of Clinical Chemistry. No information regarding sterility, single-use, or MRI safety is provided in the available data.
Other devices from Chiron Diagnostics Corp.
Questions
AI-generated answers, 1 Oct 2026
What is the ACS:180 Troponin I Assay (CTNI) used for?
The ACS:180 Troponin I Assay (CTNI) is an immunoassay designed to quantify cardiac troponin I, a biomarker critical for detecting myocardial infarction and diagnosing acute coronary syndromes. By measuring troponin I levels in patient samples, clinicians can identify heart damage and assess the severity of cardiac events, supporting timely intervention.
How is the ACS:180 Troponin I Assay (CTNI) supplied and used?
This assay is supplied as a reagent kit specifically for use with the ACS:180 Automated Chemiluminescence System. It is intended for in vitro diagnostic use in clinical laboratories, where it analyzes troponin I levels in serum or heparinized plasma samples. The automated system ensures precise and sensitive detection, streamlining workflow in diagnostic settings.
Is the ACS:180 Troponin I Assay (CTNI) single-use or reusable?
The ACS:180 Troponin I Assay (CTNI) reagent kit is designed for single-use per test run on the ACS:180 system. While the system itself may be reusable, the reagents are intended for one-time use to maintain accuracy and prevent cross-contamination, adhering to standard in vitro diagnostic practices.
What sample types can the ACS:180 Troponin I Assay (CTNI) analyze?
The assay is approved for use with serum and heparinized plasma samples. These sample types are commonly used in clinical settings to measure cardiac troponin I levels, ensuring compatibility with standard laboratory workflows for diagnosing acute coronary syndromes.
What regulatory pathway does the ACS:180 Troponin I Assay (CTNI) follow?
The ACS:180 Troponin I Assay (CTNI) received FDA 510(k) clearance under the traditional pathway, classified as a Class II device under regulation number 862.1215. This classification indicates it is a moderate-risk device regulated under the Clinical Chemistry specialty, ensuring it meets stringent performance and safety standards for diagnostic use.