Skip to content

Cholesterol Enzymatic Endpoint

by Randox Laboratories, Ltd.

510(k) K923504

Cholesterol Enzymatic Endpoint is a medical device (FDA Class I; FDA product code CHH, Enzymatic Esterase--Oxidase, Cholesterol) made by Randox Laboratories, Ltd., cleared under FDA 510(k) K923504 on 10 Jan 1994, active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK923504 Date10 Jan 1994ClearedStatusActive

Official records

From the FDA record

Received by the FDA
15 Jul 1992
FDA decision
10 Jan 1994 (Substantially Equivalent)
FDA review time
544 days from receipt to decision
Public document
510(k) statement on file with the FDA

From the FDA 510(k) record K923504 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

3 recalls · FDA

    • Terminated Z-1424-2022 FDA Class II initiated 22 Jun 2022

    Product fails to meet the performance claims quoted on the kit insert: Manual Procedure when calibrating using the standard provided in the kit, the change in absorbance is lower than expected generating internal quality control results high outside range; Cholesterol (CHOL) Instrument Specific Application using the recommended calibration material CAL2351, the product fails to meet its linearity performance claim quoted on the kit inserts. The linearity is reduced by up to -35% however Quality Control results will still fall within assigned ranges. This may lead to delayed results.

    • Terminated Z-0328-2022 FDA Class II initiated 1 Nov 2021

    When calibrating using the standard provided in the kit, the change in absorbance is lower than expected generating internal quality control results high outside range

    • Terminated Z-1652-2016 FDA Class II initiated 17 Mar 2016 on shared 510(k) K923504

    Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn from patients receiving N-Acetylcysteine (NAC) or Metamizole. NAC is the accepted antidote for acetaminophen toxicity and is justified in patients at signific

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K923504
  2. Recall initiated FDA recalls Z-1652-2016
  3. Recall initiated FDA recalls Z-0328-2022
  4. Recall initiated FDA recalls Z-1424-2022

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CHH
Device class
Class I
Regulation
21 CFR Part 862.1175
Advisory committee
Clinical Chemistry
FDA decision
SESE Substantially Equivalent

Devices cleared under K923504

3 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K923504
UDI-DISize and differences
ADVIA® Chemistry CHOL_2 Cholesterol_2 Reagent 10376501
Siemens Healthcare Diagnostics
10376501 / 1037650100630414561073
Prescription: no; Single use: no
No longer on the market
ADVIA® Chemistry CHOL_c Cholesterol Reagents, Concentrated 10335874
Siemens Healthcare Diagnostics Inc.
4993681 / 1033587400630414526744
Prescription: no; Single use: no
On the market
CHOL CH3810
Randox Laboratories, Ltd.
CH3810 / CH381005055273201284
Prescription: yes; Single use: yes
On the market

Similar devices

Other devices filed under FDA product code CHH (Enzymatic Esterase--Oxidase, Cholesterol).

Other devices from Randox Laboratories, Ltd.

See all devices from Randox Laboratories, Ltd. →