Clinac iX 9.1

by Varian Medical Systems, Inc.

Clinac iX 9.1 is a linear accelerator system (FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Varian Medical Systems, Inc., cleared under FDA 510(k) K203766 on 12 Feb 2021 (3 earlier submissions) and listed in FDA GUDID since 10 Sep 2016 (UDI-DI 00899475002042), active as of 8 Nov 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Source GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK203766 Date12 Feb 2021DecidedStatusActive
United StatesGUDID listing Number00899475002042 UDI-DI Date10 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 8 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K203766 decided 12 Feb 2021 Active· +3 more in the status table
  • FDA GUDID UDI-DI 00899475002042 listed 10 Sep 2016 Listed

Recalls

3 recalls · FDA

    • Terminated Z-2654-2014 FDA Class II initiated 18 Aug 2014 on shared 510(k) K133331

    Due to user error, the 4DITC can improperly allow users to clear a safety interlock imposed by the 4DITC on behalf of Varian's Bar Code Conical Verification system from the BrainLab's ExacTract console when it is used with BCCV.

    • Terminated Z-0552-2014 FDA Class II initiated 18 Nov 2013 on shared 510(k) K131807

    An anomaly has been traced to a software deficiency within the Plan Parameters workspace. When a dose relevant parameter is changed and "do no clear MUs and Reference Point dose" is selected, the Monitor units may change.

    • Terminated Z-0439-2014 FDA Class II initiated 24 Oct 2013

    This correction is to notify users that a solution to a previous correction has been developed and Varians reps will be contacting locations to schedule installation.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

8 dated events

  1. Cleared FDA 510(k) K131807
  2. Recall initiated FDA recalls Z-0439-2014
  3. Recall initiated FDA recalls Z-0552-2014
  4. Cleared FDA 510(k) K133331
  5. Recall initiated FDA recalls Z-2654-2014
  6. Listed FDA GUDID 00899475002042
  7. Cleared FDA 510(k) K162476
  8. Cleared FDA 510(k) K203766

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Clinac iX
Generic name
Linear accelerator system
Model / reference
9.1
Primary DI / UDI-DI
00899475002042
FDA product code
IYE
GMDN term
Linear accelerator system
Device class
Class II
Regulation number
892.5050
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code IYE (Accelerator, linear, medical).

Other devices from Varian Medical Systems, Inc.

See all devices from Varian Medical Systems, Inc. →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)