Skip to content

Na 1062424

by Accuray Incorporated

Listed FDA GUDID listing, no authorization on record

Valid until

Not applicable

Database listing, no authorization

FDA recalls

None ongoing

8 closed

Documents

None

No authorization documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing NumberM65810624240 UDI-DI Date27 Jun 2018ListedStatusListed GUDID: in commercial distribution

Recalls

8 recalls · FDA

    • Terminated Z-0784-2021 FDA Class II initiated 10 Dec 2020

    "MLC tickle error" may result in the delivered dose to effectively rotate from the planned dose.

  • 4 recalls, same reason

    • Terminated Z-0288-2018 FDA Class II initiated 17 Nov 2017
    • Terminated Z-0289-2018 FDA Class II initiated 17 Nov 2017
    • Terminated Z-0287-2018 FDA Class II initiated 17 Nov 2017
    • Terminated Z-0286-2018 FDA Class II initiated 17 Nov 2017

    Uncontrolled couch Z-axis movement (descent)

    • Terminated Z-0507-2015 FDA Class II initiated 21 Nov 2014

    Accuray has become aware of a potential safety issue related to the TomoTherapy Treatment System caused by a failure to monitor the jaw position after a jaw error occurs. This may result in an incorrect jaw position during treatment, without generating system interruption.

    • Terminated Z-2239-2014 FDA Class II initiated 17 Jul 2014

    Accuray is voluntarily recalling TomoTherapy H Series software versions 1.2.0, 1.2.1 and 1.2.2 (Hi-Art 4.2.0, 4.2.1 and 4.2.2). Accuray has identified potential safety issues (anomalies) with these software versions.

    • Terminated Z-2240-2014 FDA Class II initiated 16 Jul 2014

    Accuray is voluntarily recalling TomoTherapy H Series software versions 2.0.0 and 2.0.1 (Hi-Art 5.0.0 and 5.0.1). Accuray has identified potential safety issues (anomalies) with these software versions.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Generic Name
Linear accelerator system
Model / Ref / Catalog
1062424
Description
Software, TomoApps, Version 5.1.3 Operating Software for TomoTherapy systems (including TomoH, TomoHD, TomoHDA) and Onrad Treatment System.
Primary DI / UDI-DI
M65810624240
510(k) Number
FDA Product Code
IYE, MUJ
GMDN Term
Linear accelerator system
Device Class
Class II
Regulation Number
892.5050
GUDID distribution status
In Commercial Distribution

Other devices from Accuray Incorporated

See all devices from Accuray Incorporated →

Properties

  • Prescription Use

Other properties (13)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Serial Number: No
  • Expiration Date: No
  • Manufacturing Date: No