Skip to content

Clinac iX 9.5

by Varian Medical Systems, Inc.

Clinac iX 9.5 is a linear accelerator system (FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Varian Medical Systems, Inc., cleared under FDA 510(k) K181404 on 28 Jun 2018 and listed in FDA GUDID since 31 Jul 2018 (UDI-DI 00899475002288), active as of 8 Nov 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K181404

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00899475002288 UDI-DI Date31 Jul 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK181404 Date28 Jun 2018DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 8 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K181404 decided 28 Jun 2018 Active
  • FDA GUDID UDI-DI 00899475002288 listed 31 Jul 2018 Listed

Recalls

1 recall · FDA

    • Terminated Z-1899-2020 FDA Class II initiated 12 Aug 2019

    After a recent upgrade to the collimator software version 8.5, the firm became aware that the multi-leaf collimator leaves did not move during an arc treatment. The issue is related to a transient carriage primary- secondary interlock due to carriage fault on the MLC that immediately preceded the initiation of the arc treatment. The issue will occur only with MLC software version 8.5 and only affects conformal arc treatments, including VMAT and RapidArc. There have been no reports of adverse health consequences due to this issue.

Timeline

3 dated events

  1. Cleared FDA 510(k) K181404
  2. Listed FDA GUDID 00899475002288
  3. Recall initiated FDA recalls Z-1899-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Clinac iX
Generic name
Linear accelerator system
Model / reference
9.5
Primary DI / UDI-DI
00899475002288
510(k) Number
FDA product code
IYE
GMDN term
Linear accelerator system
Device class
Class II
Regulation number
892.5050
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code IYE (Accelerator, linear, medical).

Other devices from Varian Medical Systems, Inc.

See all devices from Varian Medical Systems, Inc. →

Properties

  • Serial number
  • Manufacturing date
Other properties (13, all answered No)