Cobas 8000 Modular Series Analyzer

by Roche Diagnostics Corp.

510(k) K100853

Cobas 8000 Modular Series Analyzer is a medical device (FDA Class II; FDA product code DCF, Albumin, Antigen, Antiserum, Control) made by Roche Diagnostics Corp., cleared under FDA 510(k) K100853 on 9 Sep 2010, active as of 22 Oct 2026.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

Recall on shared 510(k) K100853; other models may be affected

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK100853 Date9 Sep 2010ClearedStatusActive

Official records

From the FDA record

Received by the FDA
26 Mar 2010
FDA decision
9 Sep 2010 (Substantially Equivalent)
FDA review time
167 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K100853 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

11 recalls · 1 ongoing · FDA

    • Ongoing Z-0754-2021 FDA Class II initiated 8 Dec 2020 on shared 510(k) K100853

    Potential for Changed Configuration Settings on the cobas 8000 modular analyzer series/cobas pro integrated solutions, may cause incorrect results in several affected parameters. In the case of poor sample quality, discrepant results may remain undetected due to the absence of associated data flags.

    • Terminated Z-2477-2019 FDA Class II initiated 18 Jul 2019 on shared 510(k) K100853

    Quality issue with high pressure solenoid valves

    • Terminated Z-1249-2019 FDA Class II initiated 15 Mar 2019 on shared 510(k) K100853

    The firm has confirmed complaints regarding signal drops on the cobas e 801 module after a ProCell II M bottle changeover, which may lead to incorrect medical decisions with respect to diagnostics and patient treatment.

    • Terminated Z-2136-2018 FDA Class II initiated 3 Apr 2018 on shared 510(k) K100853

    The syringe plunger on the device may be mounted in a tilted position, which applies mechanical stress to the plunger. In the worst case scenario, the plunger may crack leading to impaired syringe function.

    • Terminated Z-0675-2018 FDA Class II initiated 28 Jul 2017 on shared 510(k) K100853

    A software failure may incorrectly set the system settings to "default" settings, creating a risk of incorrect results.

    • Terminated Z-0910-2018 FDA Class II initiated 18 Jul 2017 on shared 510(k) K100853

    A warning is being added to the cobas 6000 analyzer and the cobas 8000 modular analyzer series Operators Manual to prevent operator injury during maintenance.

    • Terminated Z-0378-2018 FDA Class II initiated 29 Jun 2017 on shared 510(k) K100853

    Roche has confirmed that a possible sample mismatch issue may occur on the MODULAR ANALYTICS E 170 module, cobas e 601 analyzer, or cobas e 602 analyzer due to a software limitation.

    • Terminated Z-2049-2017 FDA Class II initiated 21 Mar 2017 on shared 510(k) K100853

    Due to a design change in 2015, corrosion on the sample probe electrical contacts can occur and lead to a disturbance of the sample liquid level detection (LLD). When disturbance of the sample liquid level detection (LLD) occurs, the affected sample probe may dip into the sample material deeper than intended. This may lead to carryover and medical risk cannot be excluded.

    • Terminated Z-0097-2017 FDA Class II initiated 15 Jul 2016 on shared 510(k) K100853

    Roche has received four reports of injury caused by the sharp edge of the center guide rail of an analyzers sample rack tray. The cleaning procedure for the sample rack tray has been revised to clarify the cleaning process.

    • Terminated Z-1449-2014 FDA Class II initiated 13 Mar 2014 on shared 510(k) K100853

    The Initial Cassette Volume Check (ICVC) is not activated on the cobas c 502 module of the cobas 8000 modular analyzer series when manually filled cobas c packs are loaded. This issue occurs with tests that use cobas c pack MULTI or empty pre-labeled cobas c packs. The ICVC feature allows the reagent probe to dive into the reagent cassette and confirm the reagent level in the bottles. This ensures

    • Terminated Z-1368-2013 FDA Class II initiated 4 Apr 2013 on shared 510(k) K100853

    When using the cobas e 602 module, Diluent Multiassay may be used for autodilution of certain assays instead of Diluent Universal. This may cause incorrect results under specific circumstances if all of the following conditions are met simultaneously: More than a total of 2000 reagent kits or diluents have been registered on the cobas e 602 modules within one system core, and two different diluent

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-1449-2014
  2. Recall initiated FDA recalls Z-0097-2017
  3. Recall initiated FDA recalls Z-2049-2017
  4. Recall initiated FDA recalls Z-0378-2018
  5. Recall initiated FDA recalls Z-0910-2018
  6. Recall initiated FDA recalls Z-0675-2018
  7. Recall initiated FDA recalls Z-2136-2018
  8. Recall initiated FDA recalls Z-1249-2019
  9. Recall initiated FDA recalls Z-2477-2019
  10. Recall initiated FDA recalls Z-0754-2021

2 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
DCF
Device class
Class II
Regulation
21 CFR Part 866.5040
Advisory committee
Immunology
FDA decision
SESE Substantially Equivalent

Devices cleared under K100853

5 devices · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K100853
UDI-DISize and differences
cobas 8000 c 502 Module 5964067001
Roche Diagnostics GmbH
05964067001 / 596406700104015630928354 —On the market
cobas 8000 c 701 Module 5641489001
Roche Diagnostics GmbH
5641489001 / 564148900104015630928255 —No longer on the market
cobas 8000 c 702 Module 6473245001
Roche Diagnostics GmbH
6473245001 / 647324500104015630930845 —No longer on the market
cobas 8000 cobas ISE module 05964075001
Roche Diagnostics GmbH
05964075001 / 0596407500104015630946341 —No longer on the market
Self-Contained ISE Support Box 08126232001
Roche Diagnostics GmbH
08126232001 / 0812623200107613336142578 —On the market