cobas c 311 analyzer
by Hitachi High-Tech Corporation
Ref 04826876001Model cobas c 311 analyzer
cobas c 311 analyzer (04826876001) is a multiple clinical chemistry analyser IVD (EU IVDR Class A; FDA Class I; FDA product code JJF, Analyzer, Chemistry, Micro, for Clinical Use) made by Hitachi High-Tech Corporation, registered in EUDAMED on 8 Feb 2022 (Basic UDI-DI 761333601323A7), cleared under FDA 510(k) K060373 on 13 Mar 2006 and listed in FDA GUDID since 20 Sep 2016 (UDI-DI 04015630925551), active as of 24 Oct 2026.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number761333601323A7 04015630925551 | Date8 Feb 2022 | StatusActive |
| United States | GUDID listing GUDID | Number04015630925551 | Date20 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK060373 | Date13 Mar 2006 | StatusActive |
Official records
- EUDAMED public site 761333601323A7
- AccessGUDID record 04015630925551
- FDA 510(k) database K060373
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 761333601323A7 registered 8 Feb 2022 Active
- FDA 510(k) K060373 decided 13 Mar 2006 Active
- FDA GUDID UDI-DI 04015630925551 listed 20 Sep 2016 Listed
Recalls
-
- Terminated Z-2476-2019
Quality issue with high pressure solenoid valves may cause inaccurate results.
-
- Terminated Z-1268-2018
Complaints have been received concerning questionable results on analyzers due to customers utilizing 13 sample tubes without tube adapters.
-
- Terminated Z-0909-2018
A warning is being added to the cobas 6000 MODULAR Series System - c501 and the cobas 8000 MODULAR Analyzer Series - c502 Operator Manuals to prevent operator injury during maintenance.
-
- Terminated Z-0378-2018
Roche has confirmed that a possible sample mismatch issue may occur on the MODULAR ANALYTICS E 170 module, cobas e 601 analyzer, or cobas e 602 analyzer due to a software limitation.
-
- Terminated Z-2049-2017
Due to a design change in 2015, corrosion on the sample probe electrical contacts can occur and lead to a disturbance of the sample liquid level detection (LLD). When disturbance of the sample liquid level detection (LLD) occurs, the affected sample probe may dip into the sample material deeper than intended. This may lead to carryover and medical risk cannot be excluded.
-
- Terminated Z-0096-2017
Roche has received four reports of injury caused by the sharp edge of the center guide rail of an analyzers sample rack tray. The cleaning procedure for the sample rack tray has been revised to clarify the cleaning process.
-
- Terminated Z-1791-2014
- Terminated Z-1792-2014
Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms.
-
- Terminated Z-0542-2009
Test results, low: Sodium, potassium and chloride results on the cobas 6000 ISE unit may exhibit a downward drift in controls and patient samples within the recommended calibration interval of 24 hours. For further information, please contact Roche Diagnostics Corporation by telephone at 800-428-2336.
-
- Terminated Z-0576-2008
Incorrect results: CRP assays may be calculated using incorrect calibration parameters which could result in falsely high or falsely low patient results being reported.
Timeline
- Recall initiated FDA recalls Z-1791-2014
- Recall initiated FDA recalls Z-1792-2014
- Recall initiated FDA recalls Z-0096-2017
- Listed FDA GUDID 04015630925551
- Recall initiated FDA recalls Z-2049-2017
- Recall initiated FDA recalls Z-0378-2018
- Recall initiated FDA recalls Z-0909-2018
- Recall initiated FDA recalls Z-1268-2018
- Recall initiated FDA recalls Z-2476-2019
- Registered EUDAMED 761333601323A7
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- cobas c 311 analyzer EUDAMEDcobas c 311 GUDID
- Generic name
- Multiple clinical chemistry analyser IVD, laboratory
- Model / Ref / Catalog
- cobas c 311 analyzer, 04826876001, 4826876001
- Primary DI / UDI-DI
- 04015630925551
- Basic UDI-DI
- 761333601323A7
- 510(k) Number
- FDA product code
- JJF
- EMDN code
- W0201010106 CHEMISTRY ANALYSERS - MODERATE ROUTINE (with ISE mode test/h > 400 and <= 800)
- GMDN term
- Multiple clinical chemistry analyser IVD, laboratory
- Device class
- Class A EUDAMEDClass I GUDID
- Regulation number
- 862.2170
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | cobas c 311 analyzer 04826876001 | 4826876001 |
| Device class | Class A | Class I |
Manufacturer details
- EUDAMED SRN
- JP-MF-000016991
- Authorised representative
- Roche Diagnostics GmbH DE-AR-000006262
Similar devices in this category
Other devices filed under CHEMISTRY ANALYSERS - MODERATE ROUTINE (with ISE mode test/h > 400 and <= 800).
- Auto-Chemistry Analyzer CS-680 by DIRUI INDUSTRIAL CO., LTD
- CS-680 3009665 by DIRUI INDUSTRIAL CO., LTD
- Chemistry Analyzer BS-480 by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- DxC 500 AU Clinical Chemistry Analyzer C63520 by Beckman Coulter, Inc.
- Chemistry Analyzer BS-490 by Shenzhen Mindray Bio-Medical Electronics Co., Ltd.
- CA-800 CA000001551 by Furuno Electric Co., Ltd.
- Pentra C400 ISE 1280241013 by Horiba Abx
- AutoMax AutoMax 200 by Avecon Healthcare Pvt. Ltd.