Comprehensive Instruments 010001792
Comprehensive Instruments 010001792 is a Class II device made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K060694 on 11 Dec 2006 and listed in FDA GUDID since 26 Oct 2016 (UDI-DI 00880304539327), active as of 23 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00880304539327 | Date26 Oct 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK060694 | Date11 Dec 2006 | StatusActive |
Official records
- AccessGUDID record 00880304539327
- FDA 510(k) database K060694
Across registries
- FDA 510(k) K060694 decided 11 Dec 2006 Active
- FDA GUDID UDI-DI 00880304539327 listed 26 Oct 2016 Listed
Recalls
-
- Terminated Z-2216-2017
Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped despite having an open Non-Conformance Report (NCR). The NCR indicated that one piece from the lot had scratches and the other non-confirming threads.
-
- Terminated Z-1859-2017
Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.
-
- Terminated Z-1658-2008
The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implant, elevating the theoretical risk of glenoid loosening, which may lead to early revision surgery. The problem may contribute to early device failure and patien
-
- Terminated Z-0660-2013
Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following three events: 1) If the PT Hybrid Glenoid Post is not fully seated into the Hybrid Base and the implant construct is implanted, then a gap of 1-3 mm will be prese
Timeline
- Recall initiated FDA recalls Z-0660-2013
- Cleared FDA 510(k) K060694
- Recall initiated FDA recalls Z-1658-2008
- Listed FDA GUDID 00880304539327
- Recall initiated FDA recalls Z-1859-2017
- Recall initiated FDA recalls Z-2216-2017
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Comprehensive Instruments
- Generic name
- Humeral head prosthesis trial, reusable
- Model / Ref / Catalog
- 010001792
- Primary DI / UDI-DI
- 00880304539327
- 510(k) Number
- FDA product code
- KWT, KWS
- GMDN term
- Humeral head prosthesis trial, reusable
- Device class
- Class II
- Regulation number
- 888.3650, 888.3660
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization