Comprehensive® Instrumentation 405998
Comprehensive Instrumentation 405998 is a humeral head prosthesis trial (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K193373 on 15 Apr 2020 (2 earlier submissions) and listed in FDA GUDID since 8 May 2022 (UDI-DI 00887868504983), active as of 22 Oct 2026. 20 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00887868504983 | Date8 May 2022 | StatusListed |
| United States | FDA 510(k)SESE | NumberK193373 | Date15 Apr 2020 | StatusActive |
Official records
- AccessGUDID record 00887868504983
- FDA 510(k) database K193373
- FDA 510(k) database K132239
- FDA 510(k) database K080642
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K193373 decided 15 Apr 2020 Active
- FDA GUDID UDI-DI 00887868504983 listed 8 May 2022 Listed
Recalls
-
- Terminated Z-1131-2021
Zimmer Biomet is conducting a lot specific medical device recall for the Comprehensive Reverse Shoulder Central Screw, 25 MM Length. It has been determined through a complaint investigation that a 40 MM length central screw was packaged and labeled as a 25 MM length central screw.
-
- Terminated Z-0619-2021
Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.
-
- Terminated Z-0093-2021
Product potentially being packaged without a taper adapter or baseplate. The package should contain one (1) baseplate and one (1) taper adapter, product may be packaged with two (2) baseplates and no (0) adapters or with no (0) baseplates and two (2) adapters
-
- Terminated Z-2144-2020
Potential presence of elevated endotoxin levels that exceed the specification limit
-
- Terminated Z-1750-2020
There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.
-
- Terminated Z-1859-2017
Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.
-
- Terminated Z-1103-2017
Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.
-
- Terminated Z-1548-2013
Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.
-
- Terminated Z-2541-2011
- Terminated Z-2542-2011
- Terminated Z-2543-2011
- Terminated Z-2544-2011
- Terminated Z-2545-2011
- Terminated Z-2546-2011
- Terminated Z-2547-2011
- Terminated Z-2548-2011
- Terminated Z-2549-2011
- Terminated Z-2550-2011
The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.
-
- Terminated Z-0712-2011
- Terminated Z-0713-2011
The firm received complaints regarding fracturing of the device.
Timeline
- Cleared FDA 510(k) K132239
- Recall initiated FDA recalls Z-1103-2017
- Recall initiated FDA recalls Z-1859-2017
- Recall initiated FDA recalls Z-1750-2020
- Cleared FDA 510(k) K193373
- Recall initiated FDA recalls Z-2144-2020
- Recall initiated FDA recalls Z-0093-2021
- Recall initiated FDA recalls Z-0619-2021
- Recall initiated FDA recalls Z-1131-2021
- Listed FDA GUDID 00887868504983
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Comprehensive® Instrumentation
- Generic name
- Humeral head prosthesis trial, reusable
- Model / Ref / Catalog
- 405998
- Primary DI / UDI-DI
- 00887868504983
- FDA product code
- PHX, KWS, HWT, PAO
- GMDN term
- Humeral head prosthesis trial, reusable
- Device class
- Class II
- Regulation number
- 888.3660, 888.4800
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code PHX (shoulder prosthesis, reverse configuration).
- Humelock II Cemented Reversible Shoulder 109-4524 by FX SOLUTIONS
- Glenoid Reconstruction System 04.01.0303 by Medacta International SA
- PRCT II 108-4555 by FX SOLUTIONS
- Inset Reverse Total Shoulder System by SHOULDER INNOVATIONS, Inc
- Humeral Eccentric Reverse Metaphysis (K210207) by Medacta International S.A.
- Augment Off-Axis Instrument System by Fix Surgical
- Glenoid Reconstruction System 04.01.0306 by Medacta International SA
- Anatomical Shoulder™ 01.04237.500 by Zimmer, Inc.
- Anatomical Shoulder™ Domelock® 01.04212.365 by Zimmer, Inc.
- Encore Reverse Shoulder Prosthesis by ENCORE MEDICAL, L.P.