Skip to content

Anatomical Shoulder™ 01.04237.500

by Zimmer, Inc.

Ref 01.04237.500

Anatomical Shoulder 01.04237.500 is a joint prosthesis implantation kit (EU MDR Class IIa; FDA Class II) made by Zimmer, Inc., registered in EUDAMED on 19 Oct 2026 (Basic UDI-DI 889024QNKX), cleared under FDA 510(k) K142403 on 24 Nov 2014 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 00889024287310), active as of 23 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K142403

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number889024QNKX Basic UDI-DI 00889024287310UDI-DIDate19 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00889024287310 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK142403 Date24 Nov 2014DecidedStatusActive

Official records

From the FDA record

Device description
AS FX SCREW FOR HUMERAL TRIAL HEAD
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 889024QNKX registered 19 Oct 2026 Active
  • FDA 510(k) K142403 decided 24 Nov 2014 Active
  • FDA GUDID UDI-DI 00889024287310 listed 24 Sep 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-2003-2016 FDA Class II initiated 17 May 2016

    In some cases it has been difficult or not possible to disassemble the adjusted Dome Centric from the AS Humeral Rasp after initial positioning of the AS Humeral Trial Head which resulted in the whole construct of the Dome Centric with the still assembled AS Humeral Rasp taken out of the humeral canal. This could cause a delay in surgery time or the surgeon could decide to close the wound without finishing the surgery, increasing the infection risk or second use of anesthesia necessary.

Timeline

4 dated events

  1. Cleared FDA 510(k) K142403
  2. Recall initiated FDA recalls Z-2003-2016
  3. Listed FDA GUDID 00889024287310
  4. Registered EUDAMED 889024QNKX

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Anatomical Shoulder™
Generic name
Joint prosthesis implantation kit, reusable
Device name
Anatomical Shoulder™ Fracture Screw for humeral trial head
Model / Ref / Catalog
01.04237.500
Primary DI / UDI-DI
00889024287310
Basic UDI-DI
889024QNKX
Direct marketing DI
00889024287310
510(k) Number
FDA product code
KWS, PHX, HSD, KWT
EMDN code
P0901040201 Shoulder prostheses non modular stems
GMDN term
Joint prosthesis implantation kit, reusable
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
888.3660, 888.3690, 888.3650
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under SHOULDER PROSTHESES NON MODULAR STEMS.

Other devices from Zimmer, Inc.

See all devices from Zimmer, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (21, all answered No)