Comprehensive Reverse Shoulder SSI003677

by Biomet Orthopedics, Inc.

Comprehensive Reverse Shoulder SSI003677 is a humeral head prosthesis trial (FDA Class II) made by Biomet Orthopedics, Inc., cleared under FDA 510(k) K080642 on 9 Jul 2008 and listed in FDA GUDID since 28 Oct 2016 (UDI-DI 00880304848375), active as of 23 Oct 2026. 15 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

17 closed

Documents

510(k) K080642

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00880304848375 UDI-DI Date28 Oct 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK080642 Date9 Jul 2008DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K080642 decided 9 Jul 2008 Active
  • FDA GUDID UDI-DI 00880304848375 listed 28 Oct 2016 Listed

Recalls

17 recalls · FDA

    • Terminated Z-2144-2020 FDA Class II initiated 17 Apr 2020 on shared 510(k) K080642

    Potential presence of elevated endotoxin levels that exceed the specification limit

    • Terminated Z-1750-2020 FDA Class II initiated 13 Mar 2020 on shared 510(k) K080642

    There were unknown bioburden levels prior to sterilization, which may affect sterility of the product.

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1103-2017 FDA Class I initiated 20 Dec 2016

    Higher than anticipated rate of fracturing due to design. Risk of revision surgery due to fracturing.

    • Terminated Z-1548-2013 FDA Class II initiated 15 May 2013

    Biomet has initiated this action following an investigation which identified that the slot on the resection guide is offset in the wrong direction. When the slot on the resection guide is offset in the wrong direction, the Steinman pin that is intended to hold the guide into place may not come into contact with the bone.

  • 10 recalls, same reason

    • Terminated Z-2545-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2541-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2549-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2548-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2547-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2550-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2546-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2542-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2544-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011
    • Terminated Z-2543-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2011

    The firm is initiating this recall following an investigation which identified the rare possibility that certain units of Comprehensive Reverse Shoulder Humeral Trays may contain a locking ring that is incorrectly assembled.

  • 2 recalls, same reason

    • Terminated Z-0712-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010
    • Terminated Z-0713-2011 FDA Unclassified (pre-2012) initiated 13 Sep 2010

    The firm received complaints regarding fracturing of the device.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

19 dated events

  1. Recall initiated FDA recalls Z-2546-2011
  2. Recall initiated FDA recalls Z-2542-2011
  3. Recall initiated FDA recalls Z-2544-2011
  4. Recall initiated FDA recalls Z-2543-2011
  5. Recall initiated FDA recalls Z-1548-2013
  6. Listed FDA GUDID 00880304848375
  7. Recall initiated FDA recalls Z-1103-2017
  8. Recall initiated FDA recalls Z-1859-2017
  9. Recall initiated FDA recalls Z-1750-2020
  10. Recall initiated FDA recalls Z-2144-2020

9 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Comprehensive Reverse Shoulder
Generic name
Humeral head prosthesis trial, reusable
Model / Ref / Catalog
SSI003677
Primary DI / UDI-DI
00880304848375
510(k) Number
FDA product code
PAO, KWS
GMDN term
Humeral head prosthesis trial, reusable
Device class
Class II
Regulation number
888.3660
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices

Other devices filed under FDA product code PAO (Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented).

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)