Skip to content

Comprehensive Shoulder System SSI000166

by Biomet Orthopedics, Inc.

Listed FDA GUDID listing, not in commercial distribution

Valid until

Not applicable

Database listing, no authorization

FDA recalls

None ongoing

4 closed

Documents

None

No authorization documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source GUDID, synced 23 Oct 2026. What this means

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00880304849556 UDI-DI Date4 Oct 2016ListedStatusListed GUDID: not in commercial distribution

Recalls

4 recalls · FDA

    • Terminated Z-2216-2017 FDA Class II initiated 26 Apr 2017

    Zimmer Biomet is conducting a voluntary recall for a single lot of the Modular Hybrid Glenoid Base Large for the Comprehensive Shoulder System after it was determined that two pieces from the lot were moved to finished goods and shipped despite having an open Non-Conformance Report (NCR). The NCR indicated that one piece from the lot had scratches and the other non-confirming threads.

    • Terminated Z-1859-2017 FDA Class II initiated 17 Feb 2017

    Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

    • Terminated Z-1658-2008 FDA Unclassified (pre-2012) initiated 13 Mar 2008

    The glenoid implant may not seat fully on the face of the natural glenoid due to inadequate measurement tolerances (tolerance stack-up) in the design of the cutter. Use of the instrument may lead to incomplete seating of the glenoid implant, elevating the theoretical risk of glenoid loosening, which may lead to early revision surgery. The problem may contribute to early device failure and patien

    • Terminated Z-0660-2013 FDA Class II initiated 6 Dec 12

    Biomet is recalling Part Number PT-113950 PT Hybrid Glenoid Post, following an investigation which identified that the male thread of the post may be oversized. This oversized condition can vary in degree and may lead to the following three events: 1) If the PT Hybrid Glenoid Post is not fully seated into the Hybrid Base and the implant construct is implanted, then a gap of 1-3 mm will be prese

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — GUDID listing Listed

Specification

GUDID

Trade Name
Comprehensive Shoulder System
Generic Name
Glenoid orthopaedic reamer
Model / Ref / Catalog
SSI000166
Primary DI / UDI-DI
00880304849556
510(k) Number
FDA Product Code
KWT, KWS
GMDN Term
Glenoid orthopaedic reamer
Device Class
Class II
Regulation Number
888.3650, 888.3660
GUDID distribution status
Not in Commercial Distribution
Sterilization Method
Moist Heat or Steam Sterilization

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Prescription Use
  • Lot / Batch Number

Other properties (12)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Contains Latex: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Serial Number: No
  • Expiration Date: No