Computed Tomography X-ray System
by Shanghai United Imaging Healthcare Co., Ltd. 6 variants
Ref 88000870, 88000228Model uCT 960+
Computed Tomography X-ray System (88000870) is a medical device (EU MDD Class IIb; EMDN category computed tomographs - 256 layers or more) made by Shanghai United Imaging Healthcare Co., Ltd., registered in EUDAMED on 8 Apr 2025 (Basic UDI-DI 697157683109NB) and cleared under FDA 510(k) K172135 on 2 Mar 2018, active as of 24 Oct 2026.
Active
Valid until
No date given
FDA recalls
6 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | Number697157683109NB 06971576831098 | Date8 Apr 2025 | StatusActive |
| European Union | CE/MDR EUDAMED | Number697157683109NB 06971576831098 | Date8 Apr 2025 | StatusActive |
| United States | FDA 510(k) 510(k) | NumberK172135 | Date2 Mar 2018 | StatusActive |
Official records
- EUDAMED public site 697157683109NB
- FDA 510(k) database K172135
Across registries
- EUDAMED Basic UDI-DI 697157683109NB registered 8 Apr 2025 Active
- FDA 510(k) K172135 decided 2 Mar 2018 Active
Recalls
-
- Ongoing Z-3279-2026
- Ongoing Z-3280-2026
Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.
-
- Ongoing Z-0219-2026
- Ongoing Z-0220-2026
Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.
-
- Ongoing Z-0447-2021
A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.
-
- Ongoing Z-2703-2020
The metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge.
-
- Terminated Z-2522-2020
Two issues were identified with the computed tomography x-ray system including an intermittent issue which may affect image data leading to artifacts; and intermittent scout scanning interruption due to occasional angle signal drift. This may result in the need for rescanning of the patient with the patient receiving an additional dose of radiation and possible use of additional contrast media.
Timeline
- Cleared FDA 510(k) K172135
- Recall initiated FDA recalls Z-2522-2020
- Recall initiated FDA recalls Z-2703-2020
- Recall initiated FDA recalls Z-0447-2021
- Registered EUDAMED 697157683109NB
- Recall initiated FDA recalls Z-0219-2026
- Recall initiated FDA recalls Z-0220-2026
- Recall initiated FDA recalls Z-3279-2026
- Recall initiated FDA recalls Z-3280-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Device name
- Computed Tomography X-ray System
- Model / reference
- uCT 960+, 88000870, 88000228
- Primary DI / UDI-DI
- 06971576831098
- Basic UDI-DI
- 697157683109NB, B-06971576831098
- EMDN code
- Z11030607 Computed tomographs - 256 layers or more
- Device class
- Class IIb
- System or procedure pack
- System which is a device in itself
- EU registration type
- Standard deviceLegacy device (under a directive)
- EU market of registration
- Poland
Manufacturer details
- EUDAMED SRN
- CN-MF-000008501
- Authorised representative
- Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001
Similar devices in this category
Other devices filed under COMPUTED TOMOGRAPHS - 256 LAYERS OR MORE.
Other devices from Shanghai United Imaging Healthcare Co., Ltd.
See all devices from Shanghai United Imaging Healthcare Co., Ltd. →