Computed Tomography X-ray System

by Shanghai United Imaging Healthcare Co., Ltd. 6 variants

Ref 88000870, 88000228Model uCT 960+

Computed Tomography X-ray System (88000870) is a medical device (EU MDD Class IIb; EMDN category computed tomographs - 256 layers or more) made by Shanghai United Imaging Healthcare Co., Ltd., registered in EUDAMED on 8 Apr 2025 (Basic UDI-DI 697157683109NB) and cleared under FDA 510(k) K172135 on 2 Mar 2018, active as of 24 Oct 2026.

Active European Union and United States

CE MDR CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

6 ongoing

Recall on shared 510(k) K172135; other models may be affected

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED Number697157683109NB Basic UDI-DI 06971576831098UDI-DIDate8 Apr 2025RegisteredStatusActive
European UnionCE/MDR EUDAMED Number697157683109NB Basic UDI-DI 06971576831098UDI-DIDate8 Apr 2025RegisteredStatusActive
United StatesFDA 510(k) 510(k) NumberK172135 Date2 Mar 2018IssuedStatusActive

Official records

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 697157683109NB registered 8 Apr 2025 Active· +1 more in the status table
  • FDA 510(k) K172135 decided 2 Mar 2018 Active

Recalls

7 recalls · 6 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-3279-2026 FDA Class II initiated 11 Aug 2026 on shared 510(k) K172135
    • Ongoing Z-3280-2026 FDA Class II initiated 11 Aug 2026 on shared 510(k) K172135

    Positron emission tomography and computed tomography x-ray systems have a software problem when Split or Local function is enabled, and multiple RIS exams are merged into a single study, that prevents patient images from being visible on the Patient Administration interface, which may result in the need for rescans.

  • 2 recalls, same reason

    • Ongoing Z-0219-2026 FDA Class II initiated 12 Sep 2025 on shared 510(k) K172135
    • Ongoing Z-0220-2026 FDA Class II initiated 12 Sep 2025 on shared 510(k) K172135

    Third-party outer covers can become trapped between patient table and gantry, causing mechanical interference during table movement.

    • Ongoing Z-0447-2021 FDA Class II initiated 5 Aug 2020 on shared 510(k) K172135

    A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

    • Ongoing Z-2703-2020 FDA Class II initiated 20 Jun 2020 on shared 510(k) K172135

    The metal edge overlap of the mylar strip in the gantry was uneven, which may create a sharp edge.

    • Terminated Z-2522-2020 FDA Class II initiated 8 May 2020 on shared 510(k) K172135

    Two issues were identified with the computed tomography x-ray system including an intermittent issue which may affect image data leading to artifacts; and intermittent scout scanning interruption due to occasional angle signal drift. This may result in the need for rescanning of the patient with the patient receiving an additional dose of radiation and possible use of additional contrast media.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K172135
  2. Recall initiated FDA recalls Z-2522-2020
  3. Recall initiated FDA recalls Z-2703-2020
  4. Recall initiated FDA recalls Z-0447-2021
  5. Registered EUDAMED 697157683109NB
  6. Recall initiated FDA recalls Z-0219-2026
  7. Recall initiated FDA recalls Z-0220-2026
  8. Recall initiated FDA recalls Z-3279-2026
  9. Recall initiated FDA recalls Z-3280-2026

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD, CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

Device name
Computed Tomography X-ray System
Model / reference
uCT 960+, 88000870, 88000228
Primary DI / UDI-DI
06971576831098
Basic UDI-DI
697157683109NB, B-06971576831098
EMDN code
Z11030607 Computed tomographs - 256 layers or more
Device class
Class IIb
System or procedure pack
System which is a device in itself
EU registration type
Standard device
Legacy device (under a directive)
EU market of registration
Poland

Manufacturer details

EUDAMED SRN
CN-MF-000008501
Authorised representative
Shanghai International Holding Corp. GmbH(Europe) DE-AR-000000001

Similar devices in this category

Other devices filed under COMPUTED TOMOGRAPHS - 256 LAYERS OR MORE.

Other devices from Shanghai United Imaging Healthcare Co., Ltd.

See all devices from Shanghai United Imaging Healthcare Co., Ltd. →

Properties

  • Measuring function
Other properties (13, all answered No)