Brilliance iCT

by Philips Medical Systems Nederland B.V.

Ref 728306

Brilliance iCT (728306) is a full-body CT system (EU MDR Class IIb; FDA Class II; FDA product code JAK, System, x-ray, tomography, computed) made by Philips Medical Systems Nederland B.V., cleared under FDA 510(k) K250648 on 27 Jun 2025, registered in EUDAMED on 3 Feb 2025 (Basic UDI-DI 0884838BM278T9) and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 00884838059474), active as of 22 Oct 2026. 9 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K250648

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK250648 Date27 Jun 2025DecidedStatusActive
European UnionCE/MDR EUDAMED Number0884838BM278T9 Basic UDI-DI 00884838059474UDI-DIDate3 Feb 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number00884838059474 UDI-DI Date23 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K250648 decided 27 Jun 2025 Active
  • EUDAMED Basic UDI-DI 0884838BM278T9 registered 3 Feb 2025 Active
  • FDA GUDID UDI-DI 00884838059474 listed 23 Sep 2016 Listed

Recalls

9 recalls · 5 ongoing · FDA

    • Ongoing Z-3040-2026 FDA Class II initiated 7 Aug 2026 UDI-DI 00884838059474 listed

    Philips has identified an unintended radiation issue with the Philips IQon, iCT, Ingenuity, and Brilliance CT 64 systems that could affect the performance of the equipment.

    • Ongoing Z-2650-2026 FDA Class II initiated 11 Jun 2026 UDI-DI 00884838059474 listed

    The clinical CT scan may not automatically trigger after the Bolus Tracking scan and may need to be triggered manually. Additional Bolus Tracking shots may occur. This may result in the clinical acquisition being inadequate for diagnosis, causing a potential for patient rescan and receiving additional radiation.

    • Ongoing Z-1315-2026 FDA Class II initiated 7 Jan 2026 UDI-DI 00884838059474 listed

    As part of the CT systems sub assembly, thirty-two (32) fasteners are used to attach the rotor to the bearing within the gantry. One or more of these fasteners may not be torqued to specification. If multiple fasteners are not torqued to specification, the rotor or rotor parts may become unsecured or displaced. While there has been no reported or observed event of expelled parts during gantry rotation, unsecured rotor parts may potentially be expelled.

    • Ongoing Z-2598-2025 FDA Class II initiated 13 Aug 2025 UDI-DI 00884838059474 listed

    The patient support table (couch) may descend unexpectedly to the lowermost position due to a component (ball screw) misalignment after a replacement.

    • Ongoing Z-1990-2021 FDA Class II initiated 1 May 2021 UDI-DI 00884838059474 listed

    Significant wear of the Monitor Bracket Assembly shaft goes unrecognized could potentially lead to the Monitor Bracket Assembly detaching from the Suspension Arm and result in potential hazard for the monitor to fall while remaining attached to the cables resulting in patient, operator, bystander, or service person to serious injury.

    • Terminated Z-2314-2021 FDA Class II initiated 8 Jun 2021 UDI-DI 00884838059474 listed

    When setting patient weight unit preferences to pounds, SynchRight P3T (Personalized Patient Protocol) software will result in increased contrast volume, resulting in increased contrast volume recommended for the patient.

    • Terminated Z-1921-2020 FDA Class II initiated 6 Apr 2020 UDI-DI 00884838059474 listed

    The bolt affixing the cooling unit to the rotor was not tightened to specification on the Philips Brilliance iCT systems.

  • 2 recalls, same reason

    • Terminated Z-0388-2018 FDA Class II initiated 10 Nov 2017 UDI-DI 00884838059474 listed
    • Terminated Z-0391-2018 FDA Class II initiated 10 Nov 2017 UDI-DI 00884838059474 listed

    Philips has identified that certain fasteners cannot be confirmed to have been torqued according to specification. If the fasteners were not torqued as specified and a failure occurs while the system is in use, the parts secured by the fasteners may become loose, which may have a potential for harm.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-0391-2018
  2. Recall initiated FDA recalls Z-1921-2020
  3. Recall initiated FDA recalls Z-1990-2021
  4. Recall initiated FDA recalls Z-2314-2021
  5. Registered EUDAMED 0884838BM278T9
  6. Cleared FDA 510(k) K250648
  7. Recall initiated FDA recalls Z-2598-2025
  8. Recall initiated FDA recalls Z-1315-2026
  9. Recall initiated FDA recalls Z-2650-2026
  10. Recall initiated FDA recalls Z-3040-2026

2 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Full-body CT system
Device name
BRILLIANCE iCT SYSTEM
Model / Ref / Catalog
728306, Brilliance iCT
Primary DI / UDI-DI
00884838059474
Basic UDI-DI
0884838BM278T9
510(k) Number
FDA product code
JAK
EMDN code
Z11030607 Computed tomographs - 256 layers or more
GMDN term
Full-body CT system
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1750
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
728306
GUDID
Brilliance iCT
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
NL-MF-000001489

Similar devices in this category

Other devices filed under COMPUTED TOMOGRAPHS - 256 LAYERS OR MORE.

Other devices from Philips Medical Systems Nederland B.V.

See all devices from Philips Medical Systems Nederland B.V. →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)