Contour® Next 7277

by Ascensia Diabetes Care Us Inc.

Contour Next 7277 (85723154) is a glucose monitoring system IVD (FDA Class II) made by Ascensia Diabetes Care Us Inc., cleared under FDA 510(k) K241787 on 27 Aug 2024 (7 earlier submissions), approved under FDA PMA P160017 on 28 Sep 2016 (1 earlier submission) and listed in FDA GUDID since 3 Nov 2017 (UDI-DI 10301937277358), active as of 23 Oct 2026. 23 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

PMA 510(k)

Valid until

No expiry

FDA authorization is not time-limited

FDA recalls

19 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK241787 Date27 Aug 2024DecidedStatusActive
United StatesGUDID listing Number10301937277358 UDI-DI Date3 Nov 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA PMAAPPR from GUDID Approved NumberP160017 Date28 Sep 2016DecidedStatusActive

Official records

From the FDA record

Device description
Blood Glucose Test strips. 35 test strips.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K241787 decided 27 Aug 2024 Active· +7 more in the status table
  • FDA PMA P160017 decided 28 Sep 2016 Active· +1 more in the status table
  • FDA GUDID UDI-DI 10301937277358 listed 3 Nov 2017 Listed

Recalls

23 recalls · 19 ongoing · FDA

    • Ongoing Z-2981-2026 FDA Class II initiated 13 Jul 2026

    Loaner insulin pumps may have been cleaned with chemically incompatible products that could damage the pump case or keypad, allow moisture ingress, and result in insulin over- or under-delivery, potentially causing hypoglycemia, hyperglycemia, or diabetic ketoacidosis.

  • 3 recalls, same reason

    • Ongoing Z-1739-2026 FDA Class II initiated 13 Feb 2026
    • Ongoing Z-1740-2026 FDA Class II initiated 13 Feb 2026
    • Ongoing Z-1742-2026 FDA Class II initiated 13 Feb 2026

    All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectively, because of changes in gravitational force impacting hydrostatic and hydrodynamic pressures. Insulin over-delivery, which can occur when the pump is elevated relative to the infusion site, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An under-delivery of insulin, which can occur at lowered pump height conditions relative to the infusion site, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.

  • 4 recalls, same reason

    • Ongoing Z-1259-2025 FDA Class II initiated 31 Jan 2025
    • Ongoing Z-1261-2025 FDA Class II initiated 31 Jan 2025
    • Ongoing Z-1265-2025 FDA Class II initiated 31 Jan 2025
    • Ongoing Z-1266-2025 FDA Class II initiated 31 Jan 2025

    All Medtronic MiniMed pumps (Paradigm series, Minimed 530G, 6XX series, and 7XX series) were found to have the potential for abnormal insulin delivery due to changes in air pressure, which can be found during airplane take-off or landing. An unexpected additional dose of insulin, which can occur during take-off, can result in severe hypoglycemia, altered mental status, seizure, coma, or death. An unexpected under-delivery of insulin, which can occur during landing, can result in severe hyperglycemia, dehydration, diabetic ketoacidosis, or death.

  • 2 recalls, same reason

    • Ongoing Z-0001-2025 FDA Class I initiated 31 Jul 2024
    • Ongoing Z-0003-2025 FDA Class I initiated 31 Jul 2024

    Insulin pumps that have been dropped, bumped, or experienced physical impact may have damage to internal electrical components, which may cause reduced pump battery life. Since the defect reduces the battery life overall, it shortens the time between low battery alarms and increases the frequency with which the user must insert a new battery. Further, the defect may also deliver the low battery alarm when there is significantly less time before the battery completely runs out, from the expected up to 10-hour buffer the low alert is supposed to signal, leading to device powering down and stopping insulin delivery unexpectedly. Per the firm, a subset of pumps with the defect showed the low alert alarm was delivered ~2.5 hours before the device shut off, however, patient reports indicate the time could be even shorter. Replacing the battery will not resolve this issue and the short battery life and the truncated low battery alert lead time will continue to occur. Early battery depletion could result in power loss and insulin delivery could be interrupted, resulting in under delivery of insulin potentially leading to hyperglycemia and/or DKA.

    • Ongoing Z-2211-2023 FDA Class II initiated 19 May 2023

    Ascensia Diabetes Care has determined through customer complaints that 580 of 2900 meters from lot number DM01T033P are reconfigured from mg/dL to mmol/L. Among them, 579 meters distributed in the United States were packaged into the meter kit and had incorrect factory-set unit of measure where the meters display glucose results in mmol/L rather than mg/dL. The standard unit of measurement for the United States is mg/dL. If a consumer does not notice the incorrect unit of measurement, it is possible that the meters glucose measurement will be read as a lower blood glucose measurement than expected, and this may result in the patients glucose level remaining high, which can potentially lead to an injury requiring immediate medical intervention.

    • Ongoing Z-0193-2023 FDA Class II initiated 20 Sep 2022

    Medtronic identified a cybersecurity vulnerability in the MiniMed 600 series Insulin Pump Systems associated with the communication protocol that could allow unauthorized access to the pump system. This unauthorized access could be used to deliver too much or too little insulin through delivery of an unintended insulin bolus or because insulin delivery is slowed or stopped, which could lead to hypoglycemia or hyperglycemia. The Remote Bolus feature on insulin pumps should be turned off to prevent the unauthorized access.

    • Ongoing Z-0855-2022 FDA Class II initiated 27 Jan 2022

    New or replacement insulin pumps are not pre-programmed with basal rates or other verified settings (bolus wizard settings, sensor settings, etc.), which must be set up and saved on pumps prior to use. Patients who do not realize this will receive no basal insulin, which can lead to insulin under-delivery. Insulin under-delivery can cause severe hyperglycemia, which may lead to diabetic ketoacidosis. Current device labeling does not clearly identify that these insulin pumps are capable of functioning with the default basal setting of 0.0 units/hr for all 24 hours and that no error message will appear if the default basal setting remains active. Furthermore, the labeling for the affected devices does not highlight that saving the basal settings requires multiple steps and failure to complete all steps will not save the new basal settings, nor that the steps required to set and save a basal profile and other parameters which are used as part of the bolus calculator function are different.

    • Ongoing Z-1771-2021 FDA Class II initiated 15 Mar 2021

    Due to a software design issue, under certain conditions, a software fault is detected when a large bolus delivery at quick bolus speed completes. if the user is not aware of the amount of active insulin and delivers an additional bolus, there is a risk of insulin over delivery.

  • 2 recalls, same reason

    • Ongoing Z-0516-2021 FDA Class II initiated 30 Apr 2020
    • Ongoing Z-0517-2021 FDA Class II initiated 30 Apr 2020

    Missing solder battery connection, which could interrupt power of insulin pump.

  • 2 recalls, same reason

    • Ongoing Z-0955-2020 FDA Class I initiated 21 Nov 2019
    • Ongoing Z-0956-2020 FDA Class I initiated 21 Nov 2019

    There have been reported incidents of a loose reservoir that can no longer be locked into the pump. The reservoir can become loose due to a broken or missing retainer ring that prevents a proper lock. If the reservoir is not properly locked into the pump, it could lead to over or under delivery of insulin, which could then result in hypoglycemia or hyperglycemia.

    • Ongoing Z-0683-2019 FDA Class II initiated 3 Oct 2018

    Reports of occurrences in which insulin pumps with version 4.10 software have failed to make expected audio sounds during alerts, alarms or sirens. This could cause a user to miss system notifications, alarms or sirens associated with how the pump is working, and with high and low glucose alerts.

  • 4 recalls, same reason

    • Terminated Z-2602-2017 FDA Class II initiated 8 May 2017
    • Terminated Z-2603-2017 FDA Class II initiated 8 May 2017
    • Terminated Z-2604-2017 FDA Class II initiated 8 May 2017
    • Terminated Z-2605-2017 FDA Class II initiated 8 May 2017

    Medtronic MiniMed is recalling the MiniMed 600 series insulin pump because it may become temporarily stuck, and the keypad becomes unresponsive.

Timeline

34 dated events

  1. Recall initiated FDA recalls Z-0003-2025
  2. Cleared FDA 510(k) K241787
  3. Recall initiated FDA recalls Z-1259-2025
  4. Recall initiated FDA recalls Z-1261-2025
  5. Recall initiated FDA recalls Z-1265-2025
  6. Recall initiated FDA recalls Z-1266-2025
  7. Recall initiated FDA recalls Z-1739-2026
  8. Recall initiated FDA recalls Z-1740-2026
  9. Recall initiated FDA recalls Z-1742-2026
  10. Recall initiated FDA recalls Z-2981-2026

24 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k), FDA PMA Active

Specification

GUDID

Trade name
Contour® Next
Generic name
Glucose monitoring system IVD, home-use
Model / Ref / Catalog
7277, 85723154
Primary DI / UDI-DI
10301937277358
FDA product code
LFR, NBW, OZP, OZO
GMDN term
Glucose monitoring system IVD, home-use
Device class
Class II
Regulation number
862.1345
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code LFR (Glucose Dehydrogenase, Glucose).

Other devices from Ascensia Diabetes Care Us Inc.

See all devices from Ascensia Diabetes Care Us Inc. →

Properties

  • Single use
  • Prescription use
  • Over-the-counter
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)