Skip to content

CRW® Crwtbss

by Integra Lifesciences Corp.

CRW Crwtbss is a stereotactic radiosurgical invasive head frame (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Integra Lifesciences Corp., cleared under FDA 510(k) K944463 on 26 Oct 1995 and listed in FDA GUDID since 26 Jul 2016 (UDI-DI 10381780251996), active as of 23 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

510(k) K944463

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10381780251996 UDI-DI Date26 Jul 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK944463 Date26 Oct 1995DecidedStatusActive

Official records

From the FDA record

Device description
CRW® Trunion Reticle Set
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K944463 decided 26 Oct 1995 Active
  • FDA GUDID UDI-DI 10381780251996 listed 26 Jul 2016 Listed

Recalls

4 recalls · FDA

    • Terminated Z-0025-2016 FDA Class II initiated 21 Aug 2015

    Integra identified that the UCHRAP component (Arc Adapter Plate) would not assemble properly to the UCHRAR component (ARC Adapter Ring) of the Compact Head Ring Adapter due to an error in the manufacturing drawing.

  • 2 recalls, same reason

    • Terminated Z-2428-2012 FDA Class II initiated 9 Aug 2012
    • Terminated Z-2429-2012 FDA Class II initiated 9 Aug 2012

    T-handle screw is used on a complementary product to the CRW, the Integra HRAIM, which is the CT-compatible intubation Head Ring Assembly. When the T-handle on the HRAIM intubation hoop is tightened, the T-handle could stop in a vertical position that prevents the CRWPRECISE and certain models of the CRW-ASL from seating properly on the head ring although it appears to be fully seated

    • Terminated Z-1400-2011 FDA Unclassified (pre-2012) initiated 12 Jan 2011

    Overall length of the intubation hoop in the HRAIM Intubation Head Ring Assembly is too long and will not allow a device to to attach

Timeline

6 dated events

  1. Cleared FDA 510(k) K944463
  2. Recall initiated FDA recalls Z-1400-2011
  3. Recall initiated FDA recalls Z-2428-2012
  4. Recall initiated FDA recalls Z-2429-2012
  5. Recall initiated FDA recalls Z-0025-2016
  6. Listed FDA GUDID 10381780251996

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Crw®
Generic name
Stereotactic radiosurgical invasive head frame
Model / reference
CRWTBSS
Primary DI / UDI-DI
10381780251996
510(k) Number
FDA product code
HAW
GMDN term
Stereotactic radiosurgical invasive head frame
Device class
Class II
Regulation number
882.4560
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide

Similar devices

Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).

Other devices from Integra Lifesciences Corp.

See all devices from Integra Lifesciences Corp. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)